Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00089 - 565 Pioneer Rd - Rockcreek Townhomes #192Permit Inspection Summary Permit Status of (Open) as of Report Date: 03/27/2019 9:19 am Permit Details Permit Number: 17-00089 Rockcreek Townhomes #192 565 Pioneer Rd Building - Single Family Residence Permit Issued Date: 03/29/2017 Permit Inspection Statistics 24Total Inspections Completed: 20Total Inspections Passed: Inspection Pass Rate: 83.33% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 03/30/2017PassTed DyeResidential Footing Inspection 03/30/2017PassTed DyeFoundation Inspection 03/30/2017FailTed DyeSheeting Those Spots that the sheeting missed being nailed to the studs is marked with pink paint. * The 3" grid pattern that is required for portal frame designs, on both side of the garage door, through the osb., over the garage door header has not been done. Inspector Comments: 07/10/2017FailLarry BeesleySheeting There are some studs that were not nailed , they are marked with orange paint.Inspector Comments: 09/26/2017PassLarry BeesleyResidential Insulation Inspection Insulation only behind the bath tubs.Inspector Comments: 10/13/2017PassLarry BeesleyResidential Framing/Structure Inspection 12/18/2017N/ALarry BeesleyRadon-Ground Inspection Radon has not been required on these unites.Inspector Comments: 12/18/2017PassTed DyeSheeting The corrections were maid on the nailing of sheeting.Inspector Comments: 12/27/2017PassLarry BeesleyResidential Framing/Structure Inspection The framing is good. Fire blocking foam is to be completed before the insulation. Two main wires in the garage need to be fire caulked. I pointed it out to Brads helper. You can now go ahead with the insulation.12-27-17 Inspector Comments: 01/16/2018PassLarry BeesleyResidential Insulation Inspection 02/01/2018FailLarry BeesleyResidential Sheetrock/Drywall Inspection Make correction and call for a re inspection. ThanksInspector Comments: 02/12/2018PassLarry BeesleyResidential Sheetrock/Drywall Inspection There was no re-inspection called in on the missing screws, so I stopped by today to check. The taper was texturing the walls in the front room. He told me he had seen the missing screws and had them installed. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 17-00089 Rockcreek Townhomes #192 565 Pioneer Rd Building - Single Family Residence Permit Status of (Open) as of Report Date: 03/27/2019 9:19 am Permit Inspection Summary 03/29/2018PassLarry BeesleyResidential Building Final Every thing in the unit is complete, Outside steel needs grading and Landscaping to be completed as soon as possible. You also need the hole building to be protected from the other construction traffic in the front and back. You can get a temporary C.O. Inspector Comments: Electrical Inspection Type 12/21/2017PassBret StoddardResidential Electrical Rough-in 03/29/2018PassBret StoddardResidential Electrical Final Inspection Fire Inspection Type 01/09/2018PassDale PickeringFire Sprinkler Rough-in Mechanical Inspection Type 12/27/2017PassDon AllenHVAC Rough-in 01/10/2018PassDon AllenHVAC Rough-in 03/28/2018PassDon AllenHVAC Final Inspection Plumbing Inspection Type 12/27/2017PassDon AllenPlumbing Rough-in 01/10/2018PassDon AllenPlumbing Rough-in 03/28/2018PassDon AllenPlumbing Final Inspection 05/04/2018PassDon AllenPlumbing Water 05/04/2018PassDon AllenPlumbing Sewer Page 2 of 2