HomeMy WebLinkAboutPLANS FLOOR & ROOF - 17-00285, 17-00388-00403 - 398 Pioneer Rd - Rocky Ridge Apartments - Bldg 1 - 4 plex
To:
Date:
Specification Section:
Submittal Number: 55000 -02
055000 ROUGH CARPENTRY Transmit By:
This Submittal includes the following:
Transmitted for:
Shop Drawings Product Data Samples Copy of Letter Other
For Approval For Your Use For Review and Comment Other
Remarks
Reply Due Date:
Signed:Bryan Hegsted
If Enclosures Are Not As Noted, Please Notify Us Immediatley
Attn:
Cc:
FAX:
,
FAX:
Phone:
201708HCC Job #
Master Sample
Submittal Number: 55000 -02
Jobsite Numbers:
From:Headwaters Construction Company
,
Phone: FAX:
Signature Signed Date
Drawing #DescriptionQTY
1 Floor and Roof Layout Submittal
Up
p
e
r
F
l
o
o
r
(
1
L
e
v
e
l
)
No
t
t
o
S
c
a
l
e
20
'
2
3
/
4
"
19
'
9
1
/
4
"
40
'
17
'
6
"
5'
17
'
6
"
WH
WH
W D
DW
AD
J
U
S
T
S
P
C
G
F
O
R
D
R
A
I
N
S
EX
T
R
A
J
O
I
S
T
U
N
D
E
R
W
H
1b
1b
1b
J2J2J2
J2J2J2
R1
R1
R1
R1
Pinkwood USA 2332 W. 12600 S. Unit F Riverton, Utah 84065 Client JM Thomas Layout Name Rocky Ridge Apartments Description EWP Framing Project 705 Shipping Rexburg, Idaho Created August 09, 2017 Sales Rep JD Designer CS Design Method ASD
Up
p
e
r
F
l
o
o
r
(
1
L
e
v
e
l
)
I
J
o
i
s
t
La
b
e
l
D
e
s
c
r
i
p
t
i
o
n
W
i
d
t
h
D
e
p
t
h
Q
t
y
P
l
i
e
s
P
c
s
L
e
n
g
t
h
J2
P
K
I
2
0
2.5
1
1
.
8
7
5
48 20-0-0
J1
P
K
I
2
0
2.5
1
1
.
8
7
5
12 18-0-0
Ri
m
B
o
a
r
d
La
b
e
l
D
e
s
c
r
i
p
t
i
o
n
W
i
d
t
h
D
e
p
t
h
Q
t
y
P
l
i
e
s
P
c
s
L
e
n
g
t
h
R1
1
-
1
/
8
"
x
1
1
-
7
/
8
"
A
P
A
R
a
t
e
d
R
i
m
1
.
1
2
5
1
1
.
8
7
5
17 12 Legend Wall 1-1/8"x11-7/8" APA Rated Rim PKI20 11.875Upper Floor (1 Level)Design Method ASD Building Code IBC 2012 Floor Loads Live 40 Dead 15 Deflection Joist LL Span L/480 TL Span L/240 LL Cant 2L/360 TL Cant 2L/240 Deflection Girder LL Span L/480 TL Span L/240 LL Cant 2L/360 TL Cant 2L/240 Decking Deck OSB 23/32 APA Rated Sturd-I-Floor Fastener Nailed & GluedThis drawing is a general interpretation of the construction drawings for this project and assumes the adequacy of the supporting structure. It is intended only as a general guide for the engineered wood products placement. All Dimensions, quantities and details must be carefully checked, verified by comparison to the actual field conditions and are the responsibility of the client, architect/engineer and builder. Engineered floor system does not account for roof loading unless noted otherwise.Revisions Label Abbreviations FB Flush Beam DB Dropped Beam Blk Blocking Panel PS Squash Blocks
1.
P
K
I
2
0
F
R
B
j
o
i
s
t
s
c
a
n
a
l
s
o
b
e
u
s
e
d
.
Ve
r
s
i
o
n
1
7
.
4
0
.
1
1
9
P
o
w
e
r
e
d
b
y
i
S
t
r
u
c
t
Th
i
s
l
a
y
o
u
t
i
s
t
o
b
e
u
s
e
d
a
s
a
n
i
n
s
t
a
l
l
a
t
i
o
n
g
u
i
d
e
on
l
y
.
I
t
i
s
m
e
a
n
t
t
o
b
e
u
s
e
d
i
n
c
o
n
j
u
n
c
t
i
o
n
w
i
t
h
t
he
a
r
c
h
i
t
e
c
t
u
r
a
l
a
n
d
s
t
r
u
c
t
u
r
a
l
d
r
a
w
i
n
g
s
,
n
o
t
t
o
r
e
pl
a
c
e
t
h
e
m
Rocky Ridge Apartments
17-056785T
HF
A 0 7
A 0 6
A 0 5
A 0 4
A 0 3
A 0 2
K
1
K 1
J1C
J1B
J1A
J 1 C
J 1 B
J 1 A
J1C
J1B
J1A
J 1 C
J 1 B
J 1 A
HF
A 0 7
A 0 6
A 0 5
A 0 4
A 0 3
A 0 2
K
1
K 1
J1C
J1B
J1A
J 1 C
J 1 B
J 1 A
J1C
J1B
J1A
J 1 C
J 1 B
J 1 A
A 0 1
A 0 1
V10 V10
J 1 (1 2 )
J
1
(
1
2
)
S 0 1 (4 )
3 8 -0 2 -0 0
3 8 -0 2 -0 0
17-06-00 5-00-00 17-06-00
40-00-00