HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00613 - 900 Jet Stream Dr - Headwaters Construction - HeadquartersPermit Inspection Summary Permit Status of (Issue) as of Report Date: 03/21/2019 3:28 pm Permit Details Permit Number: 17-00613 Headwaters Construction - Headquarters 900 Jet Stream Dr Building - Commercial Permit Issued Date: 11/02/2017 Permit Inspection Statistics 27Total Inspections Completed: 21Total Inspections Passed: Inspection Pass Rate: 77.78% Permit Inspection History *Refer to Individual Inspection Report for more Details 10/09/2018PassJoel GrayPublic Works Final Inspection 03/20/2019PassQuinton OwensPlanning and Zoning Final Inspection Building Inspection Type 11/13/2017PassTed DyeCommercial Footing Inspection 11/14/2017PassTed DyeFoundation Inspection 11/29/2017PassTed DyeSlab Inspection Rebar @ 18" on center in floor (2) 1/2" rebar in the footings Rebar matt in the spot footings. Inspector Comments: 02/06/2018FailQuinton OwensSheeting Missing nailing in multiple locations on first level (marked with paint on outside)Inspector Comments: 02/12/2018PassQuinton OwensSheeting Missing nailing on west side of SW corner of building was not corrected.Inspector Comments: 05/08/2018PARTPASSTed DyeCommercial Insulation Inspection 05/08/2018PassTed DyeCommercial Framing/Structure Inspection 05/23/2018PassTed DyeCommercial Insulation Inspection 06/06/2018PassTed DyeCommercial Sheetrock/Drywall Inspection 09/17/2018FailQuinton OwensCommercial Building Final Place caution label on inside of northeast exterior door for exterior "sloped landing". This was determined and agreed as a one time solution for landing sloped slightly more the 2% where correction could result in possible tripping hazard. All future landings at doors shall not exceed 2% slope. Inspector Comments: 09/21/2018PARTPASSQuinton OwensCommercial Building Final BUILDING INSPECTION APPROVED FOR TEMPORARY OCCUPANCYInspector Comments: 10/09/2018PassJoel GraySidewalk Inspection 03/20/2019PassQuinton OwensCommercial Building Final Page 1 of 2 (Continued) Permit Details Permit Number: 17-00613 Headwaters Construction - Headquarters 900 Jet Stream Dr Building - Commercial Permit Status of (Issue) as of Report Date: 03/21/2019 3:28 pm Permit Inspection Summary Electrical Inspection Type 02/15/2018PassBret StoddardCOM & MFR Electrical Service Inspection 04/30/2018PassBret StoddardCommercial Electrical Rough-in 09/05/2018PassBret StoddardCommercial Electrical Final Inspection Fire Inspection Type 09/25/2018PassDale PickeringFire Department Final Inspection Mechanical Inspection Type 05/09/2018PassDon AllenHVAC Rough-in 05/14/2018PassDon AllenHVAC Rough-in 09/11/2018PassDon AllenHVAC Final Inspection Planning & Zoning 09/21/2018PARTPASSQuinton OwensPlanning and Zoning Final Inspection P&Z approved for temporary occupancyInspector Comments: Plumbing Inspection Type Good to cover the plumbing undergroundInspector Comments: 11/20/2017PassDon AllenPlumbing Underground Inspection Good to cover the plumbing undergroundInspector Comments: 11/30/2017PassDon AllenPlumbing Water Good to cover the main water line to the building.Inspector Comments: 02/09/2018PARTPASSDon AllenPlumbing Rough-in Good to cover the DWV. Will need to see the water lines before covering them.Inspector Comments: 09/20/2018PassDon AllenPlumbing Final Inspection Page 2 of 2