Permit Status of (Open) as of Report Date: 03/12/2019 9:33 am
Permit Details Permit Number: 12-00478
816 Johnson St - SFR
816 Johnson St
Building - Single Family Residence
Permit Issued Date: 08/15/2014
Permit Inspection Statistics
19Total Inspections Completed:
16Total Inspections Passed:
Inspection Pass Rate: 84.21%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
11/13/2012PassQuinton OwensResidential Footing Inspection
Ufer installed. Footing dowels on their way. Finish supporting rebar.Inspector Comments:
11/17/2012PassQuinton OwensFoundation Inspection
Not quite ready on Friday afternoon. finished inspection on Sat. 11/17.
12/18/12 - Shear - Ext walls OK to cover.
Inspector Comments:
01/28/2013FailQuinton OwensResidential Framing/Structure Inspection
Wall sheeting OK to cover with house wrap. Need approval or fix for broken truss
chord under bonus room. Missing truss ties on west side of garage. A35 ties at
cantilevered joists (per engr). Seal electrical penetrations in return air plenum.
Incorrect truss details on site. Basement bdrms framed but not approved for
drywall. Fix corner stud by back door for drywall backing. Finish 1/2" fir out
around laundry room door.
Inspector Comments:
01/31/2013PassQuinton OwensResidential Framing/Structure Inspection
Lag screws on cantilevered joists approved per eng'r letter received 1/31. (see
file)
Inspector Comments:
02/04/2013PassQuinton OwensResidential Insulation Inspection
R-30 under Bonus room. U-factor on windows = 0.35. Windows and doors
sealed. R-13 in basement walls. Blown cellulose in framed exterior walls. R-13 on
bonus room walls plus additional insul. on attic side of wall.
Inspector Comments:
02/08/2013PassQuinton OwensResidential Sheetrock/Drywall Inspection
5/8" garage separation.1/2" sag resistant on ceiling. Attic access must be 22x30
min r.o.- (called contractor to change). Basement is unfinished.
Inspector Comments:
03/26/2013PassTed DyeSidewalk Inspection
only city side walk in front of driveway was ready for inspection 6" Plus/ granular
fill
Inspector Comments:
03/27/2013FailQuinton OwensResidential Building Final
Disable back door (no landing, steps, or railing). Front steps require a handrail.
Egress ladder in at least one window well (unfin. bsmt). Sidewalk unfinished.
Temp (30 day) C.O. only.
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00478
816 Johnson St - SFR
816 Johnson St
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 03/12/2019 9:33 am
Permit
Inspection
Summary
Electrical Inspection Type
01/24/2013PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-inspected the service on the
rough-in, therefore no separate ticket was written for the service.
Inspector Comments:
01/24/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-unfinished basement entirely, must install a receptacle near
the stairs for the final, inspected the electrical service on the rough-in.
Inspector Comments:
03/27/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-main level, unfinished basement and no A/C unit is
installed(60A OCPD installed for it including the disconnect oustide-landscape
wiring is terminated in box next to panel and ends there.
Inspector Comments:
Mechanical Inspection Type
01/11/2013FailQuinton OwensHVAC Rough-in
No bath fans installed yet. (re-inspect with framing)Inspector Comments:
02/04/2013PassQuinton OwensHVAC Rough-in
Seal electrical penetration in RA plenum in basement (unfinished).Inspector Comments:
03/27/2013PassQuinton OwensHVAC Final Inspection
Non-direct vent furnace and water heater using same combustion air vent.
Inspection for comb. air needed when basement is finished.
Inspector Comments:
Plumbing Inspection Type
11/21/2012PassDon AllenPlumbing Sewer
Sewer is all good to cover.Inspector Comments:
11/21/2012PassDon AllenPlumbing Water
12/14/2012PassDon AllenPlumbing Underground Inspection
01/08/2013PassDon AllenPlumbing Rough-in
All good to cover up rough in.Inspector Comments:
03/27/2013PassDon AllenPlumbing Final Inspection
All good for the C/OInspector Comments: