HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00373 - 1128 Horizon Dr - SFRPermit
Inspection
Summary
Permit Status of (Issue) as of Report Date: 03/12/2019 8:27 am
Permit Details Permit Number: 12-00373
1128 Horizon Dr - SFR
1128 Horizon Dr
Building - Single Family Residence
Permit Issued Date: 07/01/2014
Permit Inspection Statistics
21Total Inspections Completed:
16Total Inspections Passed:
Inspection Pass Rate: 76.19%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
09/17/2012PassQuinton OwensFooting Inspection
3 - #4 bars cont. Clearances good.
Retaining wall - 6 cont. with crossbars about 3' oc.
No ufer yet. planned for foundation.
Inspector Comments:
9/21 QO: Incomplete SW corner. (rest of Fnd. ok so far)
Action Required: Finish SW corner. Rebar 3" clearance to dirt.
Inspector Comments:
09/24/2012PassQuinton OwensFoundation Inspection
9/24/12 QO: Rebar completed.Inspector Comments:
03/08/2013FailQuinton OwensFraming/Structure Inspection
Hole too large in bearing stud by electrical panel. Protect furnace vent in closet
top and bottom plates. Attic access? No shear wall panels, hold downs, or straps
as per plans. Gt fix or approval from structural designer. Sheathing not
completely nailed (see marks on studs). Columns supporting basement beam not
located per plan (approval on relocation needed).
Inspector Comments:
03/19/2013PassQuinton OwensFraming/Structure Inspection
03/22/2013PassQuinton OwensInsulation Inspection
Blown fiberglass in ext. walls. Vent baffles installed. Windows & Doors sealed.
Window u-factor =0.28.
Inspector Comments:
04/25/2013PassTed DyeSheetrock/Drywall Inspection
5/8" sheetrock on garage ceiling and walls
nail patterns look good.
*****
2 bedrooms and a bathoom finished in basement.
Inspector Comments:
07/11/2013FailQuinton OwensBuilding Final
Handrail needed at bottom and 2nd from top stair runs.
CO det needed outside South bsmt bdrm.
Inspector Comments:
07/26/2013PassQuinton OwensBuilding Final
Page 1 of 3
(Continued)
Permit Details Permit Number: 12-00373
1128 Horizon Dr - SFR
1128 Horizon Dr
Building - Single Family Residence
Permit Status of (Issue) as of Report Date: 03/12/2019 8:27 am
Permit
Inspection
Summary
Electrical Inspection Type
02/19/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover in the main level entirely, north two bedrooms and one
bathroom in the basement, the remaining portion of the basement is unfinished.
Inspector Comments:
02/19/2013PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-inspected the service on the
rough-in inspection therefore no seperate ticket was written.
Inspector Comments:
07/11/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C/O.
0No A/C units 30A& 40A (OCPD) (2). No hot tub connection 50A GICI disconnect.
Inspector Comments:
Mechanical Inspection Type
03/05/2013FailQuinton OwensHVAC Rough-in
Ductwork not finished near mech. room. Rest of venting and ductwork sealed and
approved. Fireplace installation and vent clearances ok. Need to inspect
remaining mech. rough in, including gas line extension to furnace and water
heater locations.
Pipe shields missing over furnace vent on closet side through main floor.
Inspector Comments:
03/22/2013PassQuinton OwensHVAC Rough-in
Rest of ductwork at mechanical room to be inspected at final.Inspector Comments:
07/11/2013FailQuinton OwensHVAC Final Inspection
Vent termination covers missing at back of house.(1 bth, 1 dryer)Inspector Comments:
01/10/2014PassQuinton OwensHVAC Final Inspection
Plumbing Inspection Type
10/05/2012PassDon AllenPlumbing Underground Inspection
All good to cover ground work.Inspector Comments:
11/02/2012PassDon AllenPlumbing Sewer
All good to cover sewer and water.Inspector Comments:
11/02/2012PassDon AllenPlumbing Water
All good to cover sewer and water.Inspector Comments:
02/08/2013PassDon AllenPlumbing Rough-in
all good to cover the rough inInspector Comments:
07/12/2013FailDon AllenPlumbing Final Inspection
needs to cut a hole for the tub moterInspector Comments:
08/09/2013PassDon AllenPlumbing Final Inspection
all good for the c/oInspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 12-00373
1128 Horizon Dr - SFR
1128 Horizon Dr
Building - Single Family Residence
Permit Status of (Issue) as of Report Date: 03/12/2019 8:27 am
Permit
Inspection
Summary
Page 3 of 3