Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00145 - 713 Engleman St - Basement FinishPermit Inspection Summary Permit Status of (Issue) as of Report Date: 03/11/2019 8:57 am Permit Details Permit Number: 12-00145 713 Engleman St - Basement Finish 713 Engleman St SFR Basement Finish Permit Issued Date: 06/06/2014 Permit Inspection Statistics 12Total Inspections Completed: 10Total Inspections Passed: Inspection Pass Rate: 83.33% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/20/2012PassQuinton OwensFraming/Structure Inspection PT or moisture resistant wood on concrete. Good drainage in area, lots of sand underground, giving untreated plates a good chance for no moisture problems. Advised to at least change baseplate on exterior walls. Inspector Comments: 04/23/2012PassQuinton OwensInsulation Inspection R-13 Batts installed in basement exterior walls.Inspector Comments: 05/08/2012PassQuinton OwensSheetrock/Drywall Inspection Drywall ok to tape.Inspector Comments: 11/19/2012PassQuinton OwensBuilding Final Electrical Inspection Type 04/18/2012FailPLL ADMINSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Need to add receptacle on wall greater than 24" (2 places), call for a re-inspect when ready-as per Jane Shaw. Inspector Comments: 04/19/2012PassPLL ADMINSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-as per Jane Shaw.Inspector Comments: 11/19/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Need to install tamper resistant receptacles throughout the basement finish-any of them that are new, AFCI protection is required for all bedroom outlets, call for a re-inspect when ready. AFCI protection was not provided because the bedroom circuits are existing from the original construction of the home as per the owner Joshua Holt. Inspector Comments: 04/26/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O. in the basement finish west portion starting at the stairs after bath receptacle is changed out for a tamper resistant type-Josh(owner) agreed to change. Inspector Comments: Mechanical Inspection Type 04/20/2012PassQuinton OwensHVAC Rough-in 11/19/2012PassQuinton OwensHVAC Final Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 12-00145 713 Engleman St - Basement Finish 713 Engleman St SFR Basement Finish Permit Status of (Issue) as of Report Date: 03/11/2019 8:57 am Permit Inspection Summary Plumbing Inspection Type 11/27/2012PassDon AllenPlumbing Rough-in 11/27/2012PassDon AllenPlumbing Final Inspection Page 2 of 2