HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00209 - 1117 Coyote Willow Way - Porch AdditionPermit
Inspection
Summary
Permit Status of (Expired) as of Report Date: 03/11/2019 8:55 am
Permit Details Permit Number: 12-00209
1117 Coyote Willow Way - Porch Addition
1117 Coyote Willow Way
Single Family Residential Addition
Permit Issued Date: 06/17/2014
Permit Inspection Statistics
2Total Inspections Completed:
0Total Inspections Passed:
Inspection Pass Rate: 0.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
07/05/2012FailQuinton OwensFraming/Structure Inspection
MSTA30 straps not installed per eng'r. No nuts on anchor bolts. Joist hangers
partially nailed (south end). Deck attached to house only with nails. Sheathing
inspected?
Inspector Comments:
08/03/2012FailQuinton OwensFraming/Structure Inspection
Previous items NOT completed:
Complete required nailing of joist hangers and tie downs. No lag bolt connection
made to house.
Inspector Comments:
Inspections Required
Building Final
Framing/Structure Inspection