Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00208 - 189 Huckleberry Cir - AdditionPermit Inspection Summary Permit Status of (Expired) as of Report Date: 03/11/2019 8:40 am Permit Details Permit Number: 12-00208 189 Huckleberry Cir - Addition 189 Huckleberry Circle Single Family Residential Addition Permit Issued Date: 06/17/2014 Permit Inspection Statistics 11Total Inspections Completed: 9Total Inspections Passed: Inspection Pass Rate: 81.82% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/07/2012PassQuinton OwensFooting Inspection rebar tied to existing footing and supported.Inspector Comments: 05/08/2012PassQuinton OwensFoundation Inspection rebar 2' o.c. each way w/ 2 in top 12" tied to exist. fnd. Inspector Comments: 05/18/2012PassQuinton OwensFraming/Structure Inspection Insufficient stapling, some studs missed (sheathing inspection 5-16, QO) Sheathing completed 5-17, QO Inspector Comments: 05/21/2012PassQuinton OwensInsulation Inspection Insulation OK Windows sealed (except basement) Action Required: fix air flow in basement addition. Inspector Comments: 05/22/2012PassQuinton OwensSheetrock/Drywall Inspection Drywall ok to tape.Inspector Comments: 08/30/2012PassQuinton OwensBuilding Final Final OK.Inspector Comments: Electrical Inspection Type 05/18/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in the addition-one bedroom main level and one in the basement if a smoke detector is installed-will re-inspect on the final. Inspector Comments: 09/06/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Need to install tamper resistant receptacles in the bedroom downstairs, label the panel for new circuits, call for a re-inspect when ready. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00208 189 Huckleberry Cir - Addition 189 Huckleberry Circle Single Family Residential Addition Permit Status of (Expired) as of Report Date: 03/11/2019 8:40 am Permit Inspection Summary Mechanical Inspection Type 05/18/2012FailQuinton OwensHVAC Rough-in Insufficient air flow in bsmt addition makes it unconditioned space requiring ceiling insulation... Fix heating problem, see mechanical Inspector Comments: 05/22/2012PassQuinton OwensHVAC Rough-in Supply air flow to basement fixed.Inspector Comments: 08/30/2012PassQuinton OwensHVAC Final Inspection Final OkInspector Comments: Inspections Required SFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Page 2 of 2