HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00177 - 455 S 12th W - Moving HousePermit Inspection Summary Permit Status of (Issue) as of Report Date: 03/07/2019 11:34 am Permit Details Permit Number: 12-00177 455 S 12th W - Moving House 455 S 12th W Building - Single Family Residence Permit Issued Date: 07/21/2014 Permit Inspection Statistics 23Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 73.91% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/03/2012FailQuinton OwensResidential Footing Inspection Rebar supported. Keep 3" clearance for low hanging sections. Basement OK to pour. Garage not 12" below undisturbed soil (existing top of grade) Inspector Comments: 05/04/2012PassQuinton OwensResidential Footing Inspection Garage footing ok to pour.Inspector Comments: 05/14/2012PassQuinton OwensFoundation Inspection Basement walls require 2 bars in top 12". Re inspection completed 1hr later.Inspector Comments: 07/30/2012FailQuinton OwensCommercial Framing/Structure Inspection New stairs to basement does not have 6'8" headroom clearance. Hangers needed on joists at stairwell. Fireblocking required at dropped ceilings. Seal between foundation and sill plate. Inspector Comments: 10/31/2012FailQuinton OwensResidential Building Final Handrails not done at deck, bsmt walkout, and inside stairs.Inspector Comments: 11/01/2012PassQuinton OwensSidewalk Inspection Not required at this time as per Keith.Inspector Comments: 11/01/2012PassQuinton OwensResidential Building Final 11/06/2012PassQuinton OwensCommercial Framing/Structure Inspection Drywalled without reinspect. Exterior Insul. inspected at openings around windows. Drywall removed to see hangers for floor joists. Spray foam applied around perimeter and brick on outside (no other sealing at sill plate done). Stringers used from homes previous location. only a few inches off (allowed as pre-existing). Inspector Comments: 11/06/2012PassQuinton OwensCommercial Insulation Inspection Drywalled without inspection request. Inspected around open window framing.Inspector Comments: 11/06/2012PassQuinton OwensCommercial Sheetrock/Drywall Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 12-00177 455 S 12th W - Moving House 455 S 12th W Building - Single Family Residence Permit Status of (Issue) as of Report Date: 03/07/2019 11:34 am Permit Inspection Summary Electrical Inspection Type 07/23/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-inspected this service on the rough-in and therefore there was no seperate inspection ticket written. Inspector Comments: 07/23/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in the basement, upper floor is existing-no changes done, circuits were re-fed from new panels in the basement-also inspected the service on this inspection. Inspector Comments: 10/10/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Need to label the main panel, range breakers are 50A-verify that the wiring is #6 or larger, panel clearance in the storage room not sufficient to meet code-3' minimum, panel in pump house is upside down-up is required to be on, call for a re-inspect when ready. Inspector Comments: 11/01/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-existing upstairs entirely and new basement entirely. Inspector Comments: Mechanical Inspection Type 07/30/2012FailQuinton OwensHVAC Rough-in New stairs to basement do not have 6' 8" headroom clearance. Hangers under joists at stairwall. Fireblocking at dropped ceilings. Seal between foundation and sill plate. Inspector Comments: 07/30/2012PassQuinton OwensHVAC Rough-in 10/31/2012FailQuinton OwensHVAC Final Inspection Strap Water Heater.Inspector Comments: 11/01/2012PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 05/21/2012PassDon AllenPlumbing Underground Inspection all good to coverInspector Comments: 06/04/2012PassDon AllenPlumbing Sewer 08/10/2012PassDon AllenPlumbing Water 08/10/2012PassDon AllenPlumbing Rough-in All good.Inspector Comments: 11/07/2012PassDon AllenPlumbing Final Inspection all good for C/OInspector Comments: Page 2 of 2