Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00072 - 242 W 6th S - Brighton Townhomes Recreation BldgPermit Inspection Summary Permit Status of (Open) as of Report Date: 03/06/2019 11:23 am Permit Details Permit Number: 12-00072 Brighton Townhomes Recreation Building 242 W 6th S Building - Commercial Permit Issued Date: 05/30/2014 Permit Inspection Statistics 21Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 80.95% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 04/04/2012PassQuinton OwensFooting Inspection Rebar clean, supported and meets clearance requirement.Inspector Comments: 04/06/2012PassQuinton OwensFoundation Inspection horz rebar 2' o.c. vert rebar ~18" o.c. Inspector Comments: 4/19/12 QO: Sheeting - missed nailing under front window north side of door; next to front door to storage room; south wall in bathroom. -need stud over joint on south wall. Inspector Comments: 05/09/2012PassQuinton OwensFraming/Structure Inspection 5/9/12 QO: firewall - 5/8" type x on exterior of back wall complete.Inspector Comments: 06/22/2012FailPLL ADMINFraming/Structure Inspection -Trusses not braced per truss details. -Could not get into crawl space. -Crawl space access NOT per code (size) -Could not check sheathing for nailing on hard downs. As per Jon Berry. Inspector Comments: 06/27/2012PassQuinton OwensFraming/Structure Inspection Framing items completed crawl space NOT inspected (need ladder) Action required: -crawl space inspection fro framing. -weep holes in masonry per IBC. Inspector Comments: 06/29/2012PassQuinton OwensInsulation Inspection Windows and doors sealed u-factor = .34 Blown ins in exterior walls. Empire model DVD42FP30N Action required: Clear insulation form behind fireplace unless 0" clearance is allowed. Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 12-00072 Brighton Townhomes Recreation Building 242 W 6th S Building - Commercial Permit Status of (Open) as of Report Date: 03/06/2019 11:23 am Permit Inspection Summary 07/03/2012PassQuinton OwensSheetrock/Drywall Inspection Ok to tape drywall. Add screws to a couple missed locations. (indicated over phone). Inspector Comments: 08/22/2012FailQuinton OwensBuilding Final -Grab bar correction in bathroom -sign by stove "for warming only." -Crawl space insulation needed at SW and NW corners, and at foundation corner between study rm and main area. (at floor joist) Inspector Comments: 08/23/2012PassQuinton OwensSidewalk Inspection 08/27/2012PassQuinton OwensBuilding Final Temp approval call when sign for stove is ready. Will check insl. in craw space as well (no ladder right now). Inspector Comments: Electrical Inspection Type 02/23/2012PassBret StoddardCommercial Electrical Rough-in approved for cover.Inspector Comments: 05/23/2012PassBret StoddardCOM & MFR Electrical Service Inspection Service approved to be energized for permanent power.Inspector Comments: 07/18/2012PassBret StoddardCOM & MFR Electrical Service Inspection approved to remain energized for permanent power. Changed panel for higher AIC rated breaker. Inspector Comments: 08/03/2012PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Fire Inspection Type 10/17/2012PassQuinton OwensFire Department Final Inspection Fire extinguishers √ Emergency lights √ Exit signs √ OK Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00072 Brighton Townhomes Recreation Building 242 W 6th S Building - Commercial Permit Status of (Open) as of Report Date: 03/06/2019 11:23 am Permit Inspection Summary Mechanical Inspection Type 06/22/2012PassPLL ADMINHVAC Rough-in HVAC and gas line looked good EXCEPT crawl space NOT checked. As per Jon Berry. Inspector Comments: 08/22/2012FailQuinton OwensHVAC Final Inspection -Grab bar correction in bathroom -sign by stove "for warming only." -Crawl space insulation needed at SW and NW corners, and at foundation corner between study rm and main area. (at floor joist) Inspector Comments: 08/27/2012PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 04/24/2012FailDon AllenPlumbing Rough-in Need to put clean out under the kitchen sink extended out 3" clean out.Inspector Comments: 05/03/2012PassDon AllenPlumbing Rough-in 09/07/2012PassDon AllenPlumbing Final Inspection All good for C/OInspector Comments: Page 3 of 3