Permit Status of (Open) as of Report Date: 03/06/2019 10:18 am
Permit Details Permit Number: 17-00208
656 Hillside Dr - New SFR
656 Hillside Dr
Building - Single Family Residence
Permit Issued Date: 06/20/2017
Permit Inspection Statistics
23Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 73.91%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
06/20/2017PARTPASSTed DyeResidential Footing Inspection
Front 3rd of house footings only(garage and back part of house yet to be
poured).
Inspector Comments:
06/26/2017PassLarry BeesleyResidential Footing Inspection
06/29/2017PassLarry BeesleyResidential Footing Inspection
07/17/2017PassLarry BeesleyFoundation Inspection
The rebar was close to forms at the bottom of the back west wall. The
contractor said they would move it before they pour that wall. They were about
to start their pour when I left. (9:15 AM) 7-17-17
Inspector Comments:
12/22/2017FailLarry BeesleySheeting
The sheeting is nailed good. There are three windows that need staples at the
seal. All of the blocking is missing. Install the blocks and staples the sheets to the
blocks, then call for a re inspection. Thanks
Inspector Comments:
01/31/2018PassLarry BeesleySheeting
Most of the blocks are in, just make sure that they are at every brace wall panel.
The brace wall panels are 20 from the start to start. R602.10.2
Inspector Comments:
03/06/2018FailLarry BeesleyResidential Framing/Structure Inspection
All of the ducts are not frame in or boxed around. The ducts in the garage will
also need to be insulated and boxed in so they can be sheet-rocked.The strap on
the garage back wall needs to b nailed.You need hangers on the stair jacks going
upstairs, and framing on the downstairs headroom area doesn't look like it is
finished. You need to add studs and blocks from the girders and beams all the
way to the foundation or footings.One stud under each truss in the girders. Make
all of the corrections and check all of your framing to make sure it is completed
and then call for a re inspection. If you have any questions call me at
208-932-6339 Make sure that the plans and truss speck sheets are available
when I do the re-inspections. Thanks Larry
Inspector Comments:
03/14/2018PassLarry BeesleyResidential Framing/Structure Inspection
Thanks Josh for making these corrections. It looks good and you are good to
Insulate.
Inspector Comments:
03/21/2018PassLarry BeesleyResidential Insulation Inspection
The insulation is all good now. Thanks for making those few corrections.Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 17-00208
656 Hillside Dr - New SFR
656 Hillside Dr
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 03/06/2019 10:18 am
Permit
Inspection
Summary
04/12/2018PassLarry BeesleySheeting
The sheeting installed on the inside of the garage door wall of the garage as per
the engineers specks. It looks good, you can sheet rock over the OSB now.
Thanks
Inspector Comments:
06/20/2018PassLarry BeesleySidewalk Inspection
The gravel is correct depth and compacted good. ThanksInspector Comments:
08/02/2018PARTPASSLarry BeesleyResidential Building Final
You are approved for a Temporary C.O. All of the work that is listed in this
report needs to be completely finished by September 3 2018 Thanks
Inspector Comments:
08/03/2018PassLarry BeesleyResidential Sheetrock/Drywall Inspection
This inspection was not called in, but I do remember looking at the sheet rock
when I did a sheeting inspection in April. Most of the house was hung and part of
the garage was done. I had Josh add more screws in the ceiling where there is
living space above the garage.
Inspector Comments:
Please call Josh before inspection 208-881-8092Inspector Comments:
12/20/2018PassLarry BeesleyResidential Building Final
All of the unfinished items have been completed and the house is now good for
the full C.O. Thanks, Larry
Inspector Comments:
Electrical Inspection Type
02/21/2018PassBret StoddardResidential Electrical Rough-in
02/21/2018PassBret StoddardResidential Electrical Service Inspection
07/23/2018PassBret StoddardResidential Electrical Final Inspection
Mechanical Inspection Type
02/09/2018PARTPASSDon AllenHVAC Rough-in
07/20/2018FailDon AllenHVAC Final Inspection
08/02/2018PassDon AllenHVAC Final Inspection
Plumbing Inspection Type
07/24/2017PassDon AllenPlumbing Underground Inspection
Good to cover the plumbing undergroundInspector Comments:
02/09/2018PassDon AllenPlumbing Rough-in
Good to cover the plumbingInspector Comments:
07/20/2018PassDon AllenPlumbing Final Inspection