HomeMy WebLinkAboutRESCHECK - 17-00208 - 656 Hillside Dr - New SFRCGenerated by REScheck-Web Software �J( Compliance Certificate Project Energy Code: 2012 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 5,975 ft2 Glazing Area 13% Climate Zone: 6 (8693 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Compliance: Passes using UA trade-off Compliance: 14.2% Better Than Code Maximum UA: 599 Your UA: 514 The % Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Ceiling: Flat or Scissor Truss 5,975 19.0 50.0 0.014 84 Wall: Wood Frame, 161n. o.c. 3,150 21.0 0.0 0.057 151 Window: Vinyl Frame, 2 Pane w/ Low -E 400 0.350 140 Door: Solid 96 0.300 29 Basement: Solid Concrete or Masonry 3,150 13.0 13.0 0.035 110 Wall height: 9.0' Depth below grade: 6.0' Insulation depth: 9.0' Compliance Statement., The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Report date: 04/21/17 Data filename: Page 1 of 8 CREScheck Software Version 5.5.0 �J( Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review Plans Verifled Value Fleld Verified Value CompliesT Comments/Assumptions & Re .ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PRI]1 energy code compliance for the ❑Not Observable ,10 building envelope. ❑Not Applicable 103.1, -Construction drawings and ❑Complies 103.2, documentation demonstrate ''❑Does Not 403.7 energy code compliance for ❑Not Observable [PR3]1 lighting and mechanical systems. ❑Not Applicable .Q, Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.6 sized per ACOA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr _ Btu/hr_ ❑Not Applicable approved by the code official. Additional Comments/Assumptions: 11 High Impact (Tier 1)2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Report date: 04/21/17 Data filename: Page 2 of 8 Section # Foundation Inspection Plans Verified Value Field Verified Value Compliest Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R-_ R- ❑Complies see the Envelope Assemblies [FO411 insulation R -value. Where interior R- R- ❑Does Not .table for values. 40 in is used, verification ❑Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm -humid locations in Climate Zone 3. 303.2 Conditioned basement wall .❑complies (FO511 Insulation Installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.8 Conditioned basement wall ft ft ❑Compiles see the Envelope Assemblies [FO611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]1 to protect exposed exterior ❑Does Not insulation and extends a '❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.8 Snow- and Ice -melting system ❑complies [F01212 controls installed. ❑Does Not �'- ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) -`;: Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Report date: 04/21/17 Data filename: Page 3 of 8 Section # & Re .ID Framing / Rough -In Inspection plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.1, 402.3.4 Door U -factor. U- U- — ❑Complles See the Envelope Assemblies [FR1]1 ❑Does Not table for values. :$. ❑Not Observable ❑Not Applicable 402.1.1,. 402.3.1, aU-factor (area -weighted averag average), e). U- U-_ ❑Complles See the Envelope Assemblies 402.3.3, - ❑Does Not table for values. 402.3.6, ❑Not Observable 402.5 ❑Not Applicable PP [FR211 d 303.1,3 U -factors of fenestration products ❑Complies [FR411 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR2311 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20] is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.4 IC -rated recessed lighting fixtures ❑Complies [FR16] sealed at housing/interior finish ❑Does Not AP and labeled to indicate 252.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 Supply ducts in attics are 1 R-R-- ❑Complies [FR12] insulated to aAll other ducts R- R❑Does Not - Ur in unconditioneded spaces or — outside the building envelope are ❑Not Observable insulated to 2-11-6. ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies FR1311 air handlers, and filter boxes are -.❑Does Not .sealed. `..❑Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [F111511 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.3HVAC piping conveying fluids R-- R-- ❑Complles [FR17]1 above 105 QF or chilled fluids ❑Does Not VV below 55 QF are Insulated to a:R- 3. ❑Not Observable ❑Not Applicable 403.3.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable . ❑Not Applicable 403.4.2 Hot water pipes are insulated to R- R- ❑Complies [FR1811 Z-11-3.0Does Not J ❑Not Observable ❑Not Applicable 1 High Impact (Tier 1) 2'. Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: Report date: 04/21/17 Page 4 of 8 # Framin / Rou h -in Ins ection plans Verified Field Verified ,,, 9 g p Value Value Complies? Comments/Assumptions 403.5 Automatic or gravity dampers are [FR19]2 installed on all outdoor air ,Nr intakes and exhausts. Additional Comments/Assumptions: ❑Does Not ❑Not Observable ❑Not Applicable 1 I High Impact (Tier 1) 2 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Report date: 04/21/17 Data filename: Page 5 of 8 --W— Insulation Ins ection P Plans Verified Value Field Verified Value Complies. Comments/Assumptions & Req. ID 303.1 All installed insulation is labeled ❑Complles [IN13]2 or the installed R -values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R -value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least Y2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 [IN3]1 wall insulation on the wall exterior, the exterior insulation ❑ Mass ❑ Mass ❑Not Observable ;y) requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4)1 ,manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) ,: Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Report date: 04/21/17 Data filename: Page 6 of 8 Section # Final inspection Provisions Plans Verified Value Field Verified Value Complies? Comments /Assumptions & Re .ID 402.1.1, Ceiling insulation R -value. R- R-_ ❑Complies see the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402'2'2' 402.2.6 ❑ Steel E] Steel ❑Not Observable [Fill' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑compiles 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every 300 W. ❑Not Observable ________ ❑Not Applicable 402 2.3 Vented attics with air permeable ❑Complies [F[22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over Insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R-_ R-_ ❑Complies [FI3]1 insulation aR-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 = ❑complies [FI17]1 ach in Climate Zones 1-2, and - ❑Does Not 0 <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.2 Duct tightness test result of <=4 cfm/100 cfm/100 ❑complies [FI4]1 cfm/100 ft2 across the system or ftz ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough -in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.2.2.1 .Air handler leakage designated ❑Complies [FI2411 by manufacturer at <=2% of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]1 installed on forced air furnaces. ❑Does Not IV ❑Not Observable ❑Not Applicable 403.1.2 -----—---_. Heat pump thermostat Installed _._. -------...----- ❑Complies [FI10]2 on heat pumps. ❑Does Not Ul ❑Not Observable ❑Not Applicable 403.4.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not u accessible manual controls. ❑Not Observable _ ❑Not Applicable 403.5.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 404.1 75% of lamps in permanent ❑Complies [FI611 fixtures or 75% of permanent ❑Does Not V, ',fixtures have high efficacy lamps. Does not apply to low -voltage ❑Not Observable '..lighting. ❑Not Applicable 1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Report date: 04/21/17 Data filename: Page 7 of 8 -- # Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Reg.ID 404.1.1 Fuel gas lighting systems have ❑complies [FI2313 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. ❑Compiles [FI712 - ❑Does Not ❑Not Observable ❑Not Applicable 3033 Manufacturer manuals for - ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) -3; Low Impact (Tier 3) Project Title: Report date: 04/21/17 Data filename: Page 8 of 8 fz2012 IECC Energy Efficiency Certificate Insulation Rating R -Value Above -Grade Wall 21.00 Below -Grade Wall 26.00 Floor 0.00 Ceiling / Roof 65.00 Ductwork (unconditioned spaces): Glass & Door Rating U -Factor SHGG Window 0.35 Door 0.30 Heating System: Cooling System: Water Heater: Name: Date: Comments