Permit Status of (Open) as of Report Date: 03/06/2019 9:36 am
Permit Details Permit Number: 12-00051
115 S 4th W - Duplex
115 S 4th W
Building - Single Family Residence
Permit Issued Date: 05/16/2014
Permit Inspection Statistics
18Total Inspections Completed:
15Total Inspections Passed:
Inspection Pass Rate: 83.33%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
02/23/2012PassQuinton OwensFooting Inspection
footings ok to pourInspector Comments:
02/24/2012PassQuinton OwensFoundation Inspection
Fixed issues with rebar on the spot
Ok to pour
Ground (electrode) rebar installed.
Inspector Comments:
04/16/2012FailQuinton OwensFraming/Structure Inspection
-Block sheathing joints by front door.
-SW corner missing hold down and solid blocking at header to corner.
-Need fasteners at 2 stud locations. (east of back door and window on wall facing
east and by SE window (2 studs to south)).
-Anchor bolts need in crawl space bearing walls.
Inspector Comments:
04/17/2012PassQuinton OwensFraming/Structure Inspection
Ok to insulate.
Will check APA panel with insulation.
Inspector Comments:
04/19/2012PassPLL ADMINInsulation Inspection
Allow insulation to dry.
Ok to cover when dry.
As per Jon Berry.
Inspector Comments:
04/23/2012PassQuinton OwensSheetrock/Drywall Inspection
Drywall ok to tape.Inspector Comments:
05/09/2012PassQuinton OwensSidewalk Inspection
5/2/12 QO: Pit run compacted. Ok to pour.
5/9/12 QO: sidewalk ok to pour. 6" pit run compacted.
Corner not done yet.
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 12-00051
115 S 4th W - Duplex
115 S 4th W
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 03/06/2019 9:36 am
Permit
Inspection
Summary
05/25/2012FailQuinton OwensBuilding Final
-House #'s.
-Carbon monoxide det. in hall.
-Guardrail in garage where walking surface >30" above adjacent floor.
Handrail at steps.
?-Fix kink in condensate line at floor in laundry room. (may cause backup?)
Inspector Comments:
07/31/2013PassQuinton OwensBuilding Final
final mech/bldg complete.Inspector Comments:
Electrical Inspection Type
04/11/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover.Inspector Comments:
04/11/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be (remain) energized for permanent power.Inspector Comments:
05/23/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Inter system bonding termination requested by main panel on both units.
-breaker lock requested for dishwasher circuit.
-label main panel.
Inspector Comments:
05/24/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.Inspector Comments:
Mechanical Inspection Type
07/31/2013PassQuinton OwensHVAC Final Inspection
final mech/bldg complete.Inspector Comments:
Plumbing Inspection Type
03/23/2012PassDon AllenPlumbing Sewer
Sewer hookup - sewer is all good to cover.Inspector Comments:
03/29/2012PassDon AllenPlumbing Sewer
sewer line - all good to coverInspector Comments:
04/13/2012PassDon AllenPlumbing Rough-in
all good to cover the walls.Inspector Comments:
06/04/2012PassDon AllenPlumbing Final Inspection