HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00051 - 115 S 4th W - DuplexPermit Inspection Summary Permit Status of (Open) as of Report Date: 03/06/2019 9:36 am Permit Details Permit Number: 12-00051 115 S 4th W - Duplex 115 S 4th W Building - Single Family Residence Permit Issued Date: 05/16/2014 Permit Inspection Statistics 18Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 83.33% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 02/23/2012PassQuinton OwensFooting Inspection footings ok to pourInspector Comments: 02/24/2012PassQuinton OwensFoundation Inspection Fixed issues with rebar on the spot Ok to pour Ground (electrode) rebar installed. Inspector Comments: 04/16/2012FailQuinton OwensFraming/Structure Inspection -Block sheathing joints by front door. -SW corner missing hold down and solid blocking at header to corner. -Need fasteners at 2 stud locations. (east of back door and window on wall facing east and by SE window (2 studs to south)). -Anchor bolts need in crawl space bearing walls. Inspector Comments: 04/17/2012PassQuinton OwensFraming/Structure Inspection Ok to insulate. Will check APA panel with insulation. Inspector Comments: 04/19/2012PassPLL ADMINInsulation Inspection Allow insulation to dry. Ok to cover when dry. As per Jon Berry. Inspector Comments: 04/23/2012PassQuinton OwensSheetrock/Drywall Inspection Drywall ok to tape.Inspector Comments: 05/09/2012PassQuinton OwensSidewalk Inspection 5/2/12 QO: Pit run compacted. Ok to pour. 5/9/12 QO: sidewalk ok to pour. 6" pit run compacted. Corner not done yet. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00051 115 S 4th W - Duplex 115 S 4th W Building - Single Family Residence Permit Status of (Open) as of Report Date: 03/06/2019 9:36 am Permit Inspection Summary 05/25/2012FailQuinton OwensBuilding Final -House #'s. -Carbon monoxide det. in hall. -Guardrail in garage where walking surface >30" above adjacent floor. Handrail at steps. ?-Fix kink in condensate line at floor in laundry room. (may cause backup?) Inspector Comments: 07/31/2013PassQuinton OwensBuilding Final final mech/bldg complete.Inspector Comments: Electrical Inspection Type 04/11/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover.Inspector Comments: 04/11/2012PassBret StoddardResidential Electrical Service Inspection Approved to be (remain) energized for permanent power.Inspector Comments: 05/23/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Inter system bonding termination requested by main panel on both units. -breaker lock requested for dishwasher circuit. -label main panel. Inspector Comments: 05/24/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Mechanical Inspection Type 07/31/2013PassQuinton OwensHVAC Final Inspection final mech/bldg complete.Inspector Comments: Plumbing Inspection Type 03/23/2012PassDon AllenPlumbing Sewer Sewer hookup - sewer is all good to cover.Inspector Comments: 03/29/2012PassDon AllenPlumbing Sewer sewer line - all good to coverInspector Comments: 04/13/2012PassDon AllenPlumbing Rough-in all good to cover the walls.Inspector Comments: 06/04/2012PassDon AllenPlumbing Final Inspection Page 2 of 2