HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00049 - 381 W 1st S - DuplexPermit Inspection Summary Permit Status of (Open) as of Report Date: 03/06/2019 9:05 am Permit Details Permit Number: 12-00049 381 W 1st S - Duplex 381 W 1st S Building - Single Family Residence Permit Issued Date: 05/14/2014 Permit Inspection Statistics 18Total Inspections Completed: 14Total Inspections Passed: Inspection Pass Rate: 77.78% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 02/23/2012PassQuinton OwensFooting Inspection footings ok to pourInspector Comments: 03/01/2012PassQuinton OwensFoundation Inspection Foundation ok to pour. Action required: protect from freezing. (3 days min) Inspector Comments: 04/11/2012FailQuinton OwensFraming/Structure Inspection √ - sheathing insufficiently fastened. - toe nailing not done on truss hangers -1 hr separation each side of attic space connection in back. Add vapor barrier to crawl space. Inspector Comments: 04/13/2012PassQuinton OwensFraming/Structure Inspection Framing items completed. Also did Gas pressure test: 29.5 at 11:56 29.5 at 12:18 Inspector Comments: 04/13/2012PassQuinton OwensInsulation Inspection Windows U-.32 Blown insul. in walls (cellulose); ducts installed to R-8; sealed around doors and windows. ACTION REQUIRED: Fire separation inside soffit at corners. (Call for inspection) Inspector Comments: 04/17/2012PassQuinton OwensSheetrock/Drywall Inspection Drywall ok to tape.Inspector Comments: 05/25/2012FailQuinton OwensBuilding Final -Carbon monoxide detector required in hall. -House Numbers Handrail (outside steps) Inspector Comments: 10/30/2012FailQuinton OwensBuilding Final Carbon monoxide det. not installed in hallway.Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 12-00049 381 W 1st S - Duplex 381 W 1st S Building - Single Family Residence Permit Status of (Open) as of Report Date: 03/06/2019 9:05 am Permit Inspection Summary 03/18/2013PassQuinton OwensBuilding Final carbon monoxide detector installed.Inspector Comments: 05/23/2014PassQuinton OwensSidewalk Inspection Sidewalk good to pour in front of home (6" compacted pit run) Corner not ready. 5/23/14 QO: approved that corner was finished. Inspector Comments: Electrical Inspection Type 04/11/2012PassBret StoddardResidential Electrical Service Inspection Service approved to remain energized for permanent power.Inspector Comments: 04/11/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover.Inspector Comments: 05/24/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Final Reinspect - approval for a final & C.O.Inspector Comments: Mechanical Inspection Type 05/25/2012PassQuinton OwensHVAC Final Inspection Plumbing Inspection Type 03/23/2012PassDon AllenPlumbing Sewer 04/13/2012FailDon AllenPlumbing Rough-in Can not see the piping in the west wall and the ceiling need to remove and recall for inspections. Inspector Comments: 04/17/2012PassDon AllenPlumbing Rough-in All good to cover.Inspector Comments: 05/23/2012PassDon AllenPlumbing Final Inspection Page 2 of 2