HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00486 - 665 Canyon Springs Dr - New SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 02/25/2019 3:43 pm
Permit Details Permit Number: 17-00486
665 Canyon Springs Dr - New SFR
665 Canyon Springs Dr
Building - Single Family Residence
Permit Issued Date: 09/14/2017
Permit Inspection Statistics
26Total Inspections Completed:
21Total Inspections Passed:
Inspection Pass Rate: 80.77%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
09/18/2017PassLarry BeesleyResidential Footing Inspection
Re bar is done per the code and forms look good.Inspector Comments:
09/19/2017PassLarry BeesleyFoundation Inspection
Re bar is correct and lapped correctly, looks good. Thanks9-19-17Inspector Comments:
01/30/2018FailLarry BeesleySheeting
A few studs were missed on the nailing and the garage door needs more nails in
the trimmers and header. There is also some blocking for the sheeting missing in
the garage. I marked everything with green paint. Please call for a re inspection
when corrections have been completed. Thanks
Inspector Comments:
02/15/2018PassLarry BeesleySheeting
All of the corrections on the nailing have been completed. THANKSInspector Comments:
03/23/2018PassLarry BeesleySheeting
The sheeting inspection had passed on 2-15-18 ThanksInspector Comments:
03/26/2018FailLarry BeesleyResidential Framing/Structure Inspection
The stud by the panel in the garage was cut out , you need to add one to the
side of the cut stud. Make the other corrections and call for a re inspection.
Inspector Comments:
04/05/2018PassLarry BeesleyResidential Framing/Structure Inspection
You steel need a stud along side the meter base in the garage. I will check that
at the insulation inspection. You are good to insulate.
Inspector Comments:
04/12/2018PassLarry BeesleyRadon-Ground Inspection
The radon has been marked on the pipe. 4-12-18Inspector Comments:
04/12/2018FailLarry BeesleyResidential Insulation Inspection
There are a few things that need to be corrected on the insulation as I listed in
this report. Also you steel need to add a stud in the garage next to the meter
base panel where the Electrician cut the stud out to fit his panel. The panel is
only screwed to the sheeting.
Inspector Comments:
04/13/2018PassLarry BeesleyResidential Insulation Inspection
You are good to sheet rock. ThanksInspector Comments:
04/24/2018PassDon AllenResidential Sheetrock/Drywall Inspection
Page 1 of 2
(Continued)
Permit Details Permit Number: 17-00486
665 Canyon Springs Dr - New SFR
665 Canyon Springs Dr
Building - Single Family Residence
Permit Status of (Open) as of Report Date: 02/25/2019 3:43 pm
Permit
Inspection
Summary
04/27/2018PARTPASSQuinton OwensResidential Sheetrock/Drywall Inspection
Framing support for drywall covering duct shall be 24" o.c. (in basement)Inspector Comments:
05/03/2018PassTed DyeResidential Sheetrock/Drywall Inspection
08/01/2018PassLarry BeesleySidewalk Inspection
The forms and gravel are good, you are good to pour the concrete. ThanksInspector Comments:
08/29/2018PassLarry BeesleyResidential Building Final
The inspetions have all passed and the house is good for the C.O. ThanksInspector Comments:
Electrical Inspection Type
03/26/2018PassBret StoddardResidential Electrical Rough-in
03/26/2018PassBret StoddardResidential Electrical Service Inspection
08/28/2018PassBret StoddardResidential Electrical Final Inspection
Mechanical Inspection Type
03/26/2018PassDon AllenHVAC Rough-in
good to cover the mechanical rough in.Inspector Comments:
04/05/2018PassDon AllenHVAC Rough-in
08/28/2018PassDon AllenHVAC Final Inspection
Plumbing Inspection Type
10/11/2017PassDon AllenPlumbing Underground Inspection
Good to cover the plumbing under groundInspector Comments:
10/24/2017PassDon AllenPlumbing Water
Good to cover the water line. Will look at the water meter at the final of project.Inspector Comments:
10/24/2017PassDon AllenPlumbing Sewer
Good to cover the sewer lineInspector Comments:
03/26/2018FailDon AllenPlumbing Rough-in
radon piping needs top be marked on every floor and attic.Inspector Comments:
08/28/2018PassDon AllenPlumbing Final Inspection
Page 2 of 2