Permit Status of (Open) as of Report Date: 02/22/2019 9:03 am
Permit Details Permit Number: 18-00478
925 River Run - Madison County Mechanical SFR
925 River Run Rd
Madison County Mechanical New SFR
Permit Issued Date: 08/30/2018
Permit Inspection Statistics
3Total Inspections Completed:
2Total Inspections Passed:
Inspection Pass Rate: 66.67%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Mechanical Inspection Type
08/30/2018FailQuinton OwensHVAC Rough-in
* Direct vent for fireplace requires a 1" clearance to combustibles (see roof
truss).
* Gas piping is not allowed in HVAC vents (see floor joist return air just south of
water heater)
* Finish sealing all joist cavities used for return air.
* Condensate drains to be completed by final inspection.
* PVC reducer on exhaust vent cannot be installed in horizontal position. Must be
between vertical and 45 degrees to allow drainage of condensate. Make
correction by final.
Inspector Comments:
09/04/2018PassDon AllenHVAC Rough-in
11/30/2018PassDon AllenHVAC Final Inspection
Inspection for PMInspector Comments: