HomeMy WebLinkAboutTRUSS SPECS - 19-00065 - 848 S 2275 W - New SFRJob
19-021521T
Truss
A1GE
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:10 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-pB7FuwVM_nicAc6KH76DI5ywOqGt2tOabMNLGtznXpl
Scale: 1/4"=1'
T2 T2
B1
ST7
ST6
ST5
ST4
ST3
ST2
ST1
ST6
ST5
ST4
ST3
ST2
T1
B1
ST1
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
AD AC AB AA Z Y X W V U T S R
4x5
3x4
5x6
5x6
5x6
3x4
28-0-0
28-0-0
-1-0-0
1-0-0
14-0-0
14-0-0
28-0-0
14-0-0
29-0-0
1-0-0
0-
4
-
3
7-
4
-
3
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [E:0-3-0,0-3-0], [M:0-3-0,0-3-0], [X:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.02
0.14
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.01
(loc)
Q
Q
P
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 147 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 28-0-0.
(lb) - Max Horz B=133(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) B, Y, Z, AA, AB, AC, AD, W, V, U, T, S, P, R
Max Grav All reactions 250 lb or less at joint(s) B, X, Y, Z, AA, AB, AC, AD, W, V, U, T, S, P, R
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, Y, Z, AA, AB, AC,
AD, W, V, U, T, S, P, R.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-021521T
Truss
A2
Truss Type
Common
Qty
7
Ply
1
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:12 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-lZE0JcWdWOyKQwGjPY8hNW28WdqoWmvt3gsSKmznXpj
Scale = 1:47.3
T2 T2
B1
W2
W1
W2
W1T1 T1
B1B2A
B
C
D
E
F
G
I HJK
5x6
3x6 5x8 5x8
6x8
6x8
3x6
9-4-0
9-4-0
18-8-0
9-4-0
28-0-0
9-4-0
-1-0-0
1-0-0
7-0-0
7-0-0
14-0-0
7-0-0
21-0-0
7-0-0
28-0-0
7-0-0
29-0-0
1-0-0
0-
4
-
3
7-
4
-
3
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [C:0-4-0,Edge], [E:0-4-0,Edge], [H:0-4-0,0-3-0], [I:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.60
0.50
0.21
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.29
-0.38
0.07
0.09
(loc)
H-I
H-I
F
B-I
l/defl
>999
>868
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 117 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W1: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-8-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1458/0-5-8 (min. 0-1-9), F=1458/0-5-8 (min. 0-1-9)
Max Horz B=133(LC 8)
Max UpliftB=-289(LC 8), F=-289(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2409/441, C-D=-2078/431, D-E=-2078/431, E-F=-2409/442
BOT CHORD B-I=-429/2036, I-J=-158/1331, J-K=-158/1331, H-K=-158/1331, F-H=-297/2036
WEBS D-H=-197/746, E-H=-573/288, D-I=-197/746, C-I=-573/288
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=289,
F=289.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-021521T
Truss
A3
Truss Type
Common
Qty
10
Ply
1
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:13 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-DmoOWyXFHi4B14rvyFgwwjaJA1AvFD90HKc0tCznXpi
Scale = 1:45.9
T2
T3
B1
W1
W2 W2
W1T1
B3B2A
B
C
D
E
F
H GIJ
5x6
4x5 3x6 5x8
6x8
5x8
1.5x4
9-4-0
9-4-0
18-8-0
9-4-0
27-9-0
9-1-0
-1-0-0
1-0-0
7-0-0
7-0-0
14-0-0
7-0-0
21-0-0
7-0-0
27-9-0
6-9-0
0-
4
-
3
7-
4
-
3
0-
5
-
1
1
6.00 12
Plate Offsets (X,Y)-- [C:0-4-0,Edge], [G:0-4-0,0-3-0], [H:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.61
0.51
0.21
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.28
-0.38
0.07
0.09
(loc)
G-H
G-H
F
F-G
l/defl
>999
>878
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 115 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W1: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-8-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)F=1343/Mechanical, B=1457/0-5-8 (min. 0-1-9)
Max Horz B=141(LC 12)
Max UpliftF=-252(LC 9), B=-289(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-2405/441, C-D=-2074/431, D-E=-2073/433, E-F=-2403/444
BOT CHORD B-H=-437/2033, H-I=-166/1329, I-J=-166/1329, G-J=-166/1329, F-G=-316/2030
WEBS C-H=-573/288, D-H=-197/746, D-G=-198/744, E-G=-569/288
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=252,
B=289.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-021521T
Truss
A4GE
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:14 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-iyMmkIYt20C2fDQ5WzB9Sx7cNRdl_hSAW_LZPeznXph
Scale = 1:47.1
T2
T3
B1
ST7
ST6
ST5
ST4
ST3
ST2
ST1
ST6
ST5
ST4
ST3
ST2
B2
ST1
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
AC AB AA Z Y X W V U T S R Q
4x5
3x4 3x4
5x6
5x6
27-9-0
27-9-0
-1-0-0
1-0-0
14-0-0
14-0-0
27-9-0
13-9-0
0-
4
-
3
7-
4
-
3
0-
5
-
1
1
6.00 12
Plate Offsets (X,Y)-- [E:0-3-0,0-3-0], [W:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.02
0.14
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
A
A
P
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 144 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 27-9-0.
(lb) - Max Horz B=141(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) B, X, Y, Z, AA, AB, AC, V, U, T, S, R, Q
Max Grav All reactions 250 lb or less at joint(s) P, B, W, X, Y, Z, AA, AB, AC, V, U, T, S, R, Q
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, X, Y, Z, AA, AB, AC
, V, U, T, S, R, Q.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-021521T
Truss
B1SGE
Truss Type
Common
Qty
1
Ply
1
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:16 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-eLUX9zZ7adSmuXaUeODdXMCtOFGBSUGTzIqgTXznXpf
Scale = 1:46.8
T1 T1
B1
W2
W1
W2
W1
ST4
ST2
ST3
ST1
ST2
ST3
ST1
ST5
ST6
B2A
B
C
D
E
F
G
M
L K J I H
Y
Z
5x6
2x4
3x4
5x6
3x4 3x4
7-4-0
7-4-0
11-2-0
3-10-0
14-8-0
3-6-0
22-0-0
7-4-0
-1-0-0
1-0-0
5-6-0
5-6-0
11-0-0
5-6-0
16-6-0
5-6-0
22-0-0
5-6-0
23-0-0
1-0-0
0-
5
-
3
6-
1
0
-
3
0-
5
-
3
7.00 12
Plate Offsets (X,Y)-- [B:Edge,0-1-8], [D:0-2-0,0-0-0], [F:0-1-0,0-1-8], [J:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.35
0.22
0.63
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.06
-0.10
0.01
0.03
(loc)
B-M
B-M
F
B-M
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 134 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W1: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-1-8 except (jt=length) B=0-5-8, L=0-3-8, L=0-3-8.
(lb) - Max Horz B=184(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) H, F except B=-166(LC 8), J=-253(LC 9)
Max Grav All reactions 250 lb or less at joint(s) K, I, H, L, L except B=755(LC 1), J=1134(LC 1), F=338(LC 20)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-883/178, C-D=-657/206, D-E=-9/333
BOT CHORD B-M=-185/694
WEBS D-J=-819/189, E-J=-449/246, D-M=-175/525, C-M=-425/235
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) H, F except (jt=lb)
B=166, J=253.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-021521T
Truss
B2
Truss Type
Common
Qty
5
Ply
1
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:17 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-6X2vMJalLxacWh9gB5ks4Zl2Beb7B2RcCyaD0zznXpe
Scale = 1:42.4
T1 T1
B1
W2
W1
W2
W1
B2A
B
C
D
E
F
G
I HJK
4x5
3x4 5x6
1.5x4
3x4
1.5x4
3x4
7-4-0
7-4-0
14-8-0
7-4-0
22-0-0
7-4-0
-1-0-0
1-0-0
5-6-0
5-6-0
11-0-0
5-6-0
16-6-0
5-6-0
22-0-0
5-6-0
23-0-0
1-0-0
0-
5
-
3
6-
1
0
-
3
0-
5
-
3
7.00 12
Plate Offsets (X,Y)-- [B:0-1-0,0-1-8], [F:0-1-0,0-1-8], [H:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.35
0.30
0.12
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.11
-0.16
0.04
0.04
(loc)
H-I
H-I
F
B-I
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 97 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W1: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-11-7 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1165/0-5-8 (min. 0-1-8), F=1165/0-5-8 (min. 0-1-8)
Max Horz B=-184(LC 6)
Max UpliftB=-229(LC 8), F=-229(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-1653/293, C-D=-1426/321, D-E=-1426/321, E-F=-1653/294
BOT CHORD B-I=-283/1312, I-J=-87/873, J-K=-87/873, H-K=-87/873, F-H=-159/1312
WEBS D-H=-163/560, E-H=-406/231, D-I=-163/560, C-I=-406/231
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=229,
F=229.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-021521T
Truss
B3GRD
Truss Type
Common Girder
Qty
1
Ply
2
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:18 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-ajbHZfbN6EiT8rktloF5dnHAv2powJ4lRcJnYQznXpd
Scale = 1:41.4
T1 T1
B1
W4
W3 W2
W1
W3W2
W1
B1
A
B
C
D
E
F
G
J I HKLMNOPQR S T
4x12
6x8
4x12
12x12
6x8
12x12
1.5x4
6x8
12x12
1.5x4
5-6-0
5-6-0
11-0-0
5-6-0
16-6-0
5-6-0
22-0-0
5-6-0
3-8-0
3-8-0
7-4-0
3-8-0
11-0-0
3-8-0
14-8-0
3-8-0
18-4-0
3-8-0
22-0-0
3-8-0
0-
5
-
3
6-
1
0
-
3
0-
5
-
3
7.00 12
Plate Offsets (X,Y)-- [A:0-1-11,0-1-12], [G:0-1-11,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.55
0.72
0.87
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.22
-0.30
0.07
0.11
(loc)
H-I
H-I
G
I-J
l/defl
>999
>865
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 274 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x8 DF 1950F 1.7E or 2x8 DF SS
WEBS 2x4 DF Stud/Std *Except*
W4: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-6-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)A=7738/0-5-8 (min. 0-4-2), G=7662/0-5-8 (min. 0-4-1)
Max Horz A=167(LC 5)
Max UpliftA=-1506(LC 8), G=-1491(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-12380/2407, B-C=-12229/2402, C-D=-8450/1694, D-E=-8450/1694, E-F=-12212/2399,
F-G=-12362/2405
BOT CHORD A-K=-2122/10525, K-L=-2122/10525, J-L=-2122/10525, J-M=-1746/8961, M-N=-1746/8961,
N-O=-1746/8961, I-O=-1746/8961, I-P=-1665/8954, P-Q=-1665/8954, Q-R=-1665/8954,
H-R=-1665/8954, H-S=-2007/10509, S-T=-2007/10509, G-T=-2007/10509
WEBS D-I=-1605/8109, E-I=-2641/627, E-H=-773/3910, C-I=-2652/628, C-J=-775/3929
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-7-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=1506,
G=1491.
8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1329 lb down and 266 lb up at
1-11-4, 1329 lb down and 266 lb up at 3-11-4, 1329 lb down and 266 lb up at 5-11-4, 1329 lb down and 266 lb up at 7-11-4, 1329 lb
down and 266 lb up at 9-11-4, 1329 lb down and 266 lb up at 11-11-4, 1329 lb down and 266 lb up at 13-11-4, 1329 lb down and 266 lb
up at 15-11-4, and 1329 lb down and 266 lb up at 17-11-4, and 1329 lb down and 266 lb up at 19-11-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
Continued on page 2
Job
19-021521T
Truss
B3GRD
Truss Type
Common Girder
Qty
1
Ply
2
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:19 2019 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-2w9fn?c0tYqKl?I3JWmK9_qLfS91fmKvgG3K4sznXpc
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-G=-84, A-G=-14
Concentrated Loads (lb)
Vert: K=-1329(B) L=-1329(B) M=-1329(B) N=-1329(B) O=-1329(B) P=-1329(B) Q=-1329(B) R=-1329(B) S=-1329(B) T=-1329(B)
Job
19-021521T
Truss
C1GE
Truss Type
Common
Qty
1
Ply
1
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:20 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-W6j1_LcedsyBN8tFtDIZiCNdqsg5OQW2uwotcIznXpb
Scale = 1:23.2
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
A
B
C
D
E
F
G
H
I
N M L K J
4x5
3x4 3x4
11-4-0
11-4-0
-1-0-0
1-0-0
5-8-0
5-8-0
11-4-0
5-8-0
12-4-0
1-0-0
0-
5
-
3
3-
8
-
1
3
0-
5
-
3
7.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.03
0.04
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
I
I
H
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 49 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-4-0.
(lb) - Max Horz B=103(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) B, H, M, N, K, J
Max Grav All reactions 250 lb or less at joint(s) B, H, L, M, N, K, J
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, M, N, K, J.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-021521T
Truss
D1
Truss Type
Monopitch
Qty
8
Ply
1
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:21 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-_IHQChdGO942?ISRQxpoEPvhJGzM7tMC7aYR9kznXpa
Scale = 1:14.6
T1
W1
B1A
B
C
D
1.5x4
2x4
1.5x4
5-10-8
5-10-8
-1-0-0
1-0-0
5-10-8
5-10-8
6-0-0
0-1-8
0-
3
-
1
5
2-
3
-
1
5
2-
0
-
7
0-
3
-
8
2-
3
-
1
5
4.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.53
0.22
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.06
-0.09
0.00
0.00
(loc)
B-D
B-D
B
l/defl
>999
>723
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 20 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-10-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=390/0-3-8 (min. 0-1-8), D=269/0-1-8 (min. 0-1-8)
Max Horz B=98(LC 4)
Max UpliftB=-115(LC 4), D=-79(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb)
B=115.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
19-021521T
Truss
E1
Truss Type
Monopitch
Qty
6
Ply
1
KARTCHNER SF12B2 ROCKFORD
Job Reference (optional)
8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:22 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-TVroP1eu9TCvcS1e_eK1ndSzIfMgsKcLMEH_hBznXpZ
Scale = 1:9.4
T1
W1
B1
A
B
C
D
1.5x4
2x4
1.5x4
1-10-8
1-10-8
-1-0-0
1-0-0
1-10-8
1-10-8
2-0-0
0-1-8
0-
4
-
3
1-
4
-
3
1-
0
-
1
1
0-
3
-
8
1-
4
-
3
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.07
0.02
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
0.00
0.00
(loc)
B
B
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 8 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 1-10-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=209/0-3-8 (min. 0-1-8), D=62/0-1-8 (min. 0-1-8)
Max Horz B=57(LC 8)
Max UpliftB=-52(LC 8), D=-21(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard