Loading...
HomeMy WebLinkAboutTRUSS SPECS - 19-00065 - 848 S 2275 W - New SFRJob 19-021521T Truss A1GE Truss Type GABLE Qty 1 Ply 1 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:10 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-pB7FuwVM_nicAc6KH76DI5ywOqGt2tOabMNLGtznXpl Scale: 1/4"=1' T2 T2 B1 ST7 ST6 ST5 ST4 ST3 ST2 ST1 ST6 ST5 ST4 ST3 ST2 T1 B1 ST1 A B C D E F G H I J K L M N O P Q AD AC AB AA Z Y X W V U T S R 4x5 3x4 5x6 5x6 5x6 3x4 28-0-0 28-0-0 -1-0-0 1-0-0 14-0-0 14-0-0 28-0-0 14-0-0 29-0-0 1-0-0 0- 4 - 3 7- 4 - 3 0- 4 - 3 6.00 12 Plate Offsets (X,Y)-- [E:0-3-0,0-3-0], [M:0-3-0,0-3-0], [X:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.07 0.02 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.01 (loc) Q Q P l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 147 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E OTHERS 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 28-0-0. (lb) - Max Horz B=133(LC 12) Max Uplift All uplift 100 lb or less at joint(s) B, Y, Z, AA, AB, AC, AD, W, V, U, T, S, P, R Max Grav All reactions 250 lb or less at joint(s) B, X, Y, Z, AA, AB, AC, AD, W, V, U, T, S, P, R FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, Y, Z, AA, AB, AC, AD, W, V, U, T, S, P, R. 10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-021521T Truss A2 Truss Type Common Qty 7 Ply 1 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:12 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-lZE0JcWdWOyKQwGjPY8hNW28WdqoWmvt3gsSKmznXpj Scale = 1:47.3 T2 T2 B1 W2 W1 W2 W1T1 T1 B1B2A B C D E F G I HJK 5x6 3x6 5x8 5x8 6x8 6x8 3x6 9-4-0 9-4-0 18-8-0 9-4-0 28-0-0 9-4-0 -1-0-0 1-0-0 7-0-0 7-0-0 14-0-0 7-0-0 21-0-0 7-0-0 28-0-0 7-0-0 29-0-0 1-0-0 0- 4 - 3 7- 4 - 3 0- 4 - 3 6.00 12 Plate Offsets (X,Y)-- [C:0-4-0,Edge], [E:0-4-0,Edge], [H:0-4-0,0-3-0], [I:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.60 0.50 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.29 -0.38 0.07 0.09 (loc) H-I H-I F B-I l/defl >999 >868 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 117 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1: 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 3-8-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=1458/0-5-8 (min. 0-1-9), F=1458/0-5-8 (min. 0-1-9) Max Horz B=133(LC 8) Max UpliftB=-289(LC 8), F=-289(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD B-C=-2409/441, C-D=-2078/431, D-E=-2078/431, E-F=-2409/442 BOT CHORD B-I=-429/2036, I-J=-158/1331, J-K=-158/1331, H-K=-158/1331, F-H=-297/2036 WEBS D-H=-197/746, E-H=-573/288, D-I=-197/746, C-I=-573/288 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=289, F=289. 6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-021521T Truss A3 Truss Type Common Qty 10 Ply 1 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:13 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-DmoOWyXFHi4B14rvyFgwwjaJA1AvFD90HKc0tCznXpi Scale = 1:45.9 T2 T3 B1 W1 W2 W2 W1T1 B3B2A B C D E F H GIJ 5x6 4x5 3x6 5x8 6x8 5x8 1.5x4 9-4-0 9-4-0 18-8-0 9-4-0 27-9-0 9-1-0 -1-0-0 1-0-0 7-0-0 7-0-0 14-0-0 7-0-0 21-0-0 7-0-0 27-9-0 6-9-0 0- 4 - 3 7- 4 - 3 0- 5 - 1 1 6.00 12 Plate Offsets (X,Y)-- [C:0-4-0,Edge], [G:0-4-0,0-3-0], [H:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.61 0.51 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.28 -0.38 0.07 0.09 (loc) G-H G-H F F-G l/defl >999 >878 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 115 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1: 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 3-8-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)F=1343/Mechanical, B=1457/0-5-8 (min. 0-1-9) Max Horz B=141(LC 12) Max UpliftF=-252(LC 9), B=-289(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD B-C=-2405/441, C-D=-2074/431, D-E=-2073/433, E-F=-2403/444 BOT CHORD B-H=-437/2033, H-I=-166/1329, I-J=-166/1329, G-J=-166/1329, F-G=-316/2030 WEBS C-H=-573/288, D-H=-197/746, D-G=-198/744, E-G=-569/288 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) F=252, B=289. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-021521T Truss A4GE Truss Type GABLE Qty 1 Ply 1 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:14 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-iyMmkIYt20C2fDQ5WzB9Sx7cNRdl_hSAW_LZPeznXph Scale = 1:47.1 T2 T3 B1 ST7 ST6 ST5 ST4 ST3 ST2 ST1 ST6 ST5 ST4 ST3 ST2 B2 ST1 A B C D E F G H I J K L M N O P AC AB AA Z Y X W V U T S R Q 4x5 3x4 3x4 5x6 5x6 27-9-0 27-9-0 -1-0-0 1-0-0 14-0-0 14-0-0 27-9-0 13-9-0 0- 4 - 3 7- 4 - 3 0- 5 - 1 1 6.00 12 Plate Offsets (X,Y)-- [E:0-3-0,0-3-0], [W:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.07 0.02 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) A A P l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 144 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E OTHERS 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 27-9-0. (lb) - Max Horz B=141(LC 8) Max Uplift All uplift 100 lb or less at joint(s) B, X, Y, Z, AA, AB, AC, V, U, T, S, R, Q Max Grav All reactions 250 lb or less at joint(s) P, B, W, X, Y, Z, AA, AB, AC, V, U, T, S, R, Q FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, X, Y, Z, AA, AB, AC , V, U, T, S, R, Q. 10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-021521T Truss B1SGE Truss Type Common Qty 1 Ply 1 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:16 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-eLUX9zZ7adSmuXaUeODdXMCtOFGBSUGTzIqgTXznXpf Scale = 1:46.8 T1 T1 B1 W2 W1 W2 W1 ST4 ST2 ST3 ST1 ST2 ST3 ST1 ST5 ST6 B2A B C D E F G M L K J I H Y Z 5x6 2x4 3x4 5x6 3x4 3x4 7-4-0 7-4-0 11-2-0 3-10-0 14-8-0 3-6-0 22-0-0 7-4-0 -1-0-0 1-0-0 5-6-0 5-6-0 11-0-0 5-6-0 16-6-0 5-6-0 22-0-0 5-6-0 23-0-0 1-0-0 0- 5 - 3 6- 1 0 - 3 0- 5 - 3 7.00 12 Plate Offsets (X,Y)-- [B:Edge,0-1-8], [D:0-2-0,0-0-0], [F:0-1-0,0-1-8], [J:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.35 0.22 0.63 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.10 0.01 0.03 (loc) B-M B-M F B-M l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 134 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1: 2x4 DF Stud/Std OTHERS 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 11-1-8 except (jt=length) B=0-5-8, L=0-3-8, L=0-3-8. (lb) - Max Horz B=184(LC 7) Max Uplift All uplift 100 lb or less at joint(s) H, F except B=-166(LC 8), J=-253(LC 9) Max Grav All reactions 250 lb or less at joint(s) K, I, H, L, L except B=755(LC 1), J=1134(LC 1), F=338(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD B-C=-883/178, C-D=-657/206, D-E=-9/333 BOT CHORD B-M=-185/694 WEBS D-J=-819/189, E-J=-449/246, D-M=-175/525, C-M=-425/235 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) H, F except (jt=lb) B=166, J=253. 9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-021521T Truss B2 Truss Type Common Qty 5 Ply 1 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:17 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-6X2vMJalLxacWh9gB5ks4Zl2Beb7B2RcCyaD0zznXpe Scale = 1:42.4 T1 T1 B1 W2 W1 W2 W1 B2A B C D E F G I HJK 4x5 3x4 5x6 1.5x4 3x4 1.5x4 3x4 7-4-0 7-4-0 14-8-0 7-4-0 22-0-0 7-4-0 -1-0-0 1-0-0 5-6-0 5-6-0 11-0-0 5-6-0 16-6-0 5-6-0 22-0-0 5-6-0 23-0-0 1-0-0 0- 5 - 3 6- 1 0 - 3 0- 5 - 3 7.00 12 Plate Offsets (X,Y)-- [B:0-1-0,0-1-8], [F:0-1-0,0-1-8], [H:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.35 0.30 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.11 -0.16 0.04 0.04 (loc) H-I H-I F B-I l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 97 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except* W1: 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 4-11-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=1165/0-5-8 (min. 0-1-8), F=1165/0-5-8 (min. 0-1-8) Max Horz B=-184(LC 6) Max UpliftB=-229(LC 8), F=-229(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD B-C=-1653/293, C-D=-1426/321, D-E=-1426/321, E-F=-1653/294 BOT CHORD B-I=-283/1312, I-J=-87/873, J-K=-87/873, H-K=-87/873, F-H=-159/1312 WEBS D-H=-163/560, E-H=-406/231, D-I=-163/560, C-I=-406/231 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 7.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=229, F=229. 6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-021521T Truss B3GRD Truss Type Common Girder Qty 1 Ply 2 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:18 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-ajbHZfbN6EiT8rktloF5dnHAv2powJ4lRcJnYQznXpd Scale = 1:41.4 T1 T1 B1 W4 W3 W2 W1 W3W2 W1 B1 A B C D E F G J I HKLMNOPQR S T 4x12 6x8 4x12 12x12 6x8 12x12 1.5x4 6x8 12x12 1.5x4 5-6-0 5-6-0 11-0-0 5-6-0 16-6-0 5-6-0 22-0-0 5-6-0 3-8-0 3-8-0 7-4-0 3-8-0 11-0-0 3-8-0 14-8-0 3-8-0 18-4-0 3-8-0 22-0-0 3-8-0 0- 5 - 3 6- 1 0 - 3 0- 5 - 3 7.00 12 Plate Offsets (X,Y)-- [A:0-1-11,0-1-12], [G:0-1-11,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.55 0.72 0.87 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.22 -0.30 0.07 0.11 (loc) H-I H-I G I-J l/defl >999 >865 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 274 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x8 DF 1950F 1.7E or 2x8 DF SS WEBS 2x4 DF Stud/Std *Except* W4: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BRACING- TOP CHORD Sheathed or 3-6-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)A=7738/0-5-8 (min. 0-4-2), G=7662/0-5-8 (min. 0-4-1) Max Horz A=167(LC 5) Max UpliftA=-1506(LC 8), G=-1491(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD A-B=-12380/2407, B-C=-12229/2402, C-D=-8450/1694, D-E=-8450/1694, E-F=-12212/2399, F-G=-12362/2405 BOT CHORD A-K=-2122/10525, K-L=-2122/10525, J-L=-2122/10525, J-M=-1746/8961, M-N=-1746/8961, N-O=-1746/8961, I-O=-1746/8961, I-P=-1665/8954, P-Q=-1665/8954, Q-R=-1665/8954, H-R=-1665/8954, H-S=-2007/10509, S-T=-2007/10509, G-T=-2007/10509 WEBS D-I=-1605/8109, E-I=-2641/627, E-H=-773/3910, C-I=-2652/628, C-J=-775/3929 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=1506, G=1491. 8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1329 lb down and 266 lb up at 1-11-4, 1329 lb down and 266 lb up at 3-11-4, 1329 lb down and 266 lb up at 5-11-4, 1329 lb down and 266 lb up at 7-11-4, 1329 lb down and 266 lb up at 9-11-4, 1329 lb down and 266 lb up at 11-11-4, 1329 lb down and 266 lb up at 13-11-4, 1329 lb down and 266 lb up at 15-11-4, and 1329 lb down and 266 lb up at 17-11-4, and 1329 lb down and 266 lb up at 19-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 Job 19-021521T Truss B3GRD Truss Type Common Girder Qty 1 Ply 2 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:19 2019 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-2w9fn?c0tYqKl?I3JWmK9_qLfS91fmKvgG3K4sznXpc LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: A-D=-84, D-G=-84, A-G=-14 Concentrated Loads (lb) Vert: K=-1329(B) L=-1329(B) M=-1329(B) N=-1329(B) O=-1329(B) P=-1329(B) Q=-1329(B) R=-1329(B) S=-1329(B) T=-1329(B) Job 19-021521T Truss C1GE Truss Type Common Qty 1 Ply 1 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:20 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-W6j1_LcedsyBN8tFtDIZiCNdqsg5OQW2uwotcIznXpb Scale = 1:23.2 T1 T1 B1 ST3 ST2 ST1 ST2 ST1 A B C D E F G H I N M L K J 4x5 3x4 3x4 11-4-0 11-4-0 -1-0-0 1-0-0 5-8-0 5-8-0 11-4-0 5-8-0 12-4-0 1-0-0 0- 5 - 3 3- 8 - 1 3 0- 5 - 3 7.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-SH 0.07 0.03 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) I I H l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E OTHERS 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.All bearings 11-4-0. (lb) - Max Horz B=103(LC 7) Max Uplift All uplift 100 lb or less at joint(s) B, H, M, N, K, J Max Grav All reactions 250 lb or less at joint(s) B, H, L, M, N, K, J FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, M, N, K, J. 10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-021521T Truss D1 Truss Type Monopitch Qty 8 Ply 1 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:21 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-_IHQChdGO942?ISRQxpoEPvhJGzM7tMC7aYR9kznXpa Scale = 1:14.6 T1 W1 B1A B C D 1.5x4 2x4 1.5x4 5-10-8 5-10-8 -1-0-0 1-0-0 5-10-8 5-10-8 6-0-0 0-1-8 0- 3 - 1 5 2- 3 - 1 5 2- 0 - 7 0- 3 - 8 2- 3 - 1 5 4.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.53 0.22 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.09 0.00 0.00 (loc) B-D B-D B l/defl >999 >723 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 20 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E WEBS 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 5-10-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=390/0-3-8 (min. 0-1-8), D=269/0-1-8 (min. 0-1-8) Max Horz B=98(LC 4) Max UpliftB=-115(LC 4), D=-79(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb) B=115. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job 19-021521T Truss E1 Truss Type Monopitch Qty 6 Ply 1 KARTCHNER SF12B2 ROCKFORD Job Reference (optional) 8.220 s Jul 21 2018 MiTek Industries, Inc. Thu Feb 7 10:51:22 2019 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:_TjNZxGN_k0MNS8nKI7_NRyswZ6-TVroP1eu9TCvcS1e_eK1ndSzIfMgsKcLMEH_hBznXpZ Scale = 1:9.4 T1 W1 B1 A B C D 1.5x4 2x4 1.5x4 1-10-8 1-10-8 -1-0-0 1-0-0 1-10-8 1-10-8 2-0-0 0-1-8 0- 4 - 3 1- 4 - 3 1- 0 - 1 1 0- 3 - 8 1- 4 - 3 6.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 35.0 7.0 0.0 * 7.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.07 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.00 0.00 0.00 (loc) B B B l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 8 lb FT = 20% GRIP 220/195 LUMBER- TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E WEBS 2x4 DF Stud/Std BRACING- TOP CHORD Sheathed or 1-10-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size)B=209/0-3-8 (min. 0-1-8), D=62/0-1-8 (min. 0-1-8) Max Horz B=57(LC 8) Max UpliftB=-52(LC 8), D=-21(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D. 7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard