Loading...
HomeMy WebLinkAboutBATTERY CALCS - 19-00015 - 2300 University Blvd - Madison High School Classroom & Gym Addition24 5 1.2 Date:10/29/2018 10 Panel ID: Model:3.0 Amps Location: Volts:24 VDC 6.0 Amps Wire AWG Ohms Per Length(ft)Actual Volts @ Standby Alarm & Type 1000 Ft.One-Way Ohms EOL SK-5208 1 0.140 0.550 SK-5217 SK-5217 Zone Expdr 0 0.000 0.000 SK-5235 0 0.000 0.000 SK-5280 0 0.000 0.000 SK-5220 0 0.000 0.000 SK-7181 0 0.000 0.000 IDC-1 NA**0.000 NA** IDC-2 NA**0.000 NA** IDC-3 NA**0.000 NA** IDC-4 NA**0.000 NA** IDC-5 NA**0.000 NA** IDC-6 NA**0.000 NA** IDC-7 NA**0.000 NA** IDC-8 NA**0.000 NA** IDC-9 NA**0.000 NA** IDC-10 NA**0.000 NA** IDC-11 NA**0.000 NA** IDC-12 NA**0.000 NA** IDC-13 NA**0.000 NA** IDC-14 NA**0.000 NA** IDC-15 NA**0.000 NA** IDC-16 NA**0.000 NA** IDC-17 NA**0.000 NA** IDC-18 NA**0.000 NA** IDC-19 NA**0.000 NA** IDC-20 NA**0.000 NA** IDC-21 NA**0.000 NA** IDC-22 NA**0.000 NA** IDC-23 NA**0.000 NA** IDC-24 NA**0.000 NA** IDC-25 NA**0.000 NA** IDC-26 NA**0.000 NA** IDC-27 NA**0.000 NA** IDC-28 NA**0.000 NA** IDC-29 NA**0.000 NA** IDC-30 NA**0.000 NA** NAC-1 ##0.000 1.290 #14 Solid 2.52 260 1.31 18.71 8.29% NAC-2 ##0.000 1.300 #12 Solid 1.59 340 1.08 18.99 6.89% NAC-3 ##0.000 1.720 #12 Solid 1.59 307 0.98 18.72 8.23% NAC-4 ##0.000 1.039 #12 Solid 1.59 425 1.35 19.00 6.88% Aux ##0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 0.140 5.899 24 0.083 (5 Mins) 3.360 0.492 Inactive, Add SK-5217 Circuit Name Initiating Device Ckt 5 Initiating Device Ckt 6 Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 Initiating Device Ckt 9 Initiating Device Ckt 10 Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 Tamper valve Pullstation Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 %Drop SK-5280 Display Mod Current Draw Version 02.26.09 SK-5208 SK-5208 Fire Alarm Control Panel Voltage Drop Warning Threshold % : Ckt.#Qty N/A Madison Event Center Project ID: Prepared By:Rye Guthrie Multiply By The Derating Factor Notification Appl Ckt 3 Standby Time In Hours Aux Power Out 3.85Total Combined AH Required SK-5208 Calculations Max NAC Current: Max Panel Current: Fire riser room Standby Hours: Alarm Mins: Derating Factor: Project Name: Total Alarm Current (Amps)Total Standby Current (Amps) Inactive, Add SK-5217 Inactive, Add SK-5217 Inactive, Add SK-5217 Alarm Time In Minutes / 60 Notification Appl Ckt 4 Notification Appl Ckt 2 Notification Appl Ckt 1 Inactive, Add SK-5217 Total Alarm AH Required Command Shortcuts Minimum Battery AmpHours Required 4.62 1.20 Total Standby AH Required **The SK-5208 and SK-5217 limits alarm current to 95mA per zone. The SK-5208 alarm current includes 10% of system zones in alarm, but in no case less than three zones per UL 864. SK-5208 Main Control SK-5235 LCD Remote SK-7181 Zn Cnvtr SK-5220 Dir Con Mod Initiating Device Ckt 7 Initiating Device Ckt 8 Water flow Smoke Detector Global Project Values: Wire resistance is taken from Chapter 9 Table 8 of the National Electric Code Wire resistance is taken from Chapter 9 Table 8 of the National Electric Code Wire resistance is taken from Chapter 9 Table 8 of the National Electric Code Wire resistance is taken from Chapter 9 Table 8 of the National Electric Code Wire resistance is taken from Chapter 9 Table 8 of the National Electric Code Wire resistance is taken from Chapter 9 Table 8 of the National Electric Code Configure Circuits Print Page