HomeMy WebLinkAboutINSPECTION TICKET - 17-00272 - 639 Handcart Ln - Savoye Apartments LLCInspection Ticket Commercial Building Final on 01/03/2019: FAIL Permit Number: 17-00272Permit Details Multi-Family Residential Permit Issued Date: 08/02/2017 Final Inspections Required Fire Alarm Final Inspection Plumbing Final Inspection Commercial Building Final Planning and Zoning Final Inspection 639 Handcart Ln 639 Handcart Ln - Savoye Apartments LLC Inspection Details quinton.owens@rexburg.org Inspected By: Quinton Owens Commercial Building Final on 01/03/2019: FAIL D ESCRIPTIO N CO M M EN TS STATUS Smoke & C.O detector outside bedrooms * Smoke alarm in NW bedroom in unit 202 is not working. * Smoke alarm by kitchen in unit 101 is not working. FAIL All special inspections are completed and reported. Has special inspection been done on stair structure? FAIL Mechanical, Electrical, Plumbing are required as well as P&Z, Public Works, Fire Dept. and Fire Sprinklers where sprinkler system exists. Not all finals have been approved FAIL All egress components (ramps, landings, stairs, handrails, guardrails, etc.) meet code. Discussion at beginning of project identified the requirement for solid risers per 2012 IBC 1009.7.5.3. * Risers are open FAIL Corridors (including doors) are rated as per plans and are proper width. Vent openings in corridor walls from corridor to equipment rooms require dampers to maintain fire rating. The one in elevator equipment room needs fire rating around damper above door. FAIL Doors are correct size, swing, and rating.Fire rated doors shall be self closing (make adjustments on closers as needed) FAIL Fire rated structural elements are sprayed, rocked, or covered as per plans. * Bearing wall left of furnace shall be rated for VA construction type. Maintain rating around duct and return air perimeter where open and at thermostat wire penetration. * Tape perimeter around opening to roof access (roof assembly is one hour rated) * Fire rating to be maintained at plastic clean outs under kitchen sink in 301,302, & 304 * Fire sprinkler missing escutcheon in 3rd level common area and in bedroom of 103 * Data room (3rd floor) has unprotected penetrations in ceiling & walls * Floor assemblies require fire rated protection - openings in floor found in water heater room on 2nd floor and in furnace closets on 2nd, 3rd, and 4th floor. FAIL Page 1 of 2 (Continued) Permit Number: 17-00272 D ESCRIPTIO N CO MMEN TS STATUS * Sprinkler escutcheon to be flush against ceiling to protect penetration (see bedroom in 201) * Finish rating penetrations in riser room (wall common to elevator room does not require fire rating). All building construction is complete.Sprinkler head in 2nd floor common area is wrapped in fabric. FAIL Page 2 of 2