PROJECT INFO - 19-00055 - 838 S 2275 W - New SFR
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 16:40:25 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Load Short Form 2/7/19Date:Entire House By: Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1476Design TD (°F) H-Daily range 5050Inside humidity (%) -3162Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMSS960603BN Cond GSX130301B AHRI ref 7365096 Coil CAPF3030D6D AHRI ref 4355516 Efficiency 96.1 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh60000 Sensible cooling Btuh19880 Heating output Btuh58000 Latent cooling Btuh8520 Temperature rise °F66 Total cooling Btuh28400 Actual air flow cfm950 Actual air flow cfm950 Air flow factor cfm/Btuh0.029 Air flow factor cfm/Btuh0.107 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room2 168 2289 1119 66 120 Room3 55 450 50 13 5 Room5 72 666 69 19 7 Room6 405 4672 844 135 90 Room7 646 13909 3171 403 339 Room10 156 2682 1226 78 131 Room11 182 2721 1235 79 132 Room12 40 0 0 0 0 Room13 226 3297 912 96 98 Room14 80 1430 161 41 17 Room15 70 674 92 20 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 16:40:25 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W Entire House d 2100 32790 8880 950 950 Other equip loads 4012 739 Equip. @ 0.94 RSM 9042 Latent cooling 0 TOTALS 2100 36802 9042 950 950 2019-Feb-07 16:40:25 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Building Analysis 2/7/19Date:Entire House By: Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 39.0143414.8Walls 11.2412224.0Glazing 1.867811.4Doors 8.731921.5Ceilings 10.137001.81.8Floors 18.467572.4Infiltration 00Ducts 00Piping 00Humidification 10.94012Ventilation0Adjustments 100.036802Total Cooling Walls Glazing Other Ceilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 11.511060.4Walls 51.9499729.1Glazing 1.71652.8Doors 18.317640.8Ceilings 2.32250.1Floors 6.56220.2Infiltration 00Ducts 7.7739Ventilation 00Internal gains 00Blower 0Adjustments 100.09619Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 45 Btuh/ft²-°F Data entries checked. 2019-Feb-07 16:40:25 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Component Constructions 2/7/19Date:Entire House By: Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) AverageConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B19-0wc-4: Bg wall, heavy dry or light damp soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh 210.109324.5019.00.047207n 230.1010534.5019.00.047234e 220.0910704.4419.00.047241s 120.095844.3919.00.047133w 780.1036394.4619.00.047815all Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 3450.4735964.9422.00.065728n 1780.4718524.9422.00.065375e 3350.4734934.9422.00.065707s 1690.4717614.9422.00.065357w 10280.47107034.9422.00.0652167all Partitions (none) Windows 61C: 61C; 6.67 ft head ht 26410.660824.300.32025n 103334.473024.300.32030e 37218.645622.800.30020s 47218.960824.300.32025s 68334.145622.800.30020w 179034.4126524.300.32052w 461326.8412224.000.320172all Doors metal: Door, mtl pur core type 582.7823911.410.50.15021e 582.7823911.410.50.15021s 492.7820011.410.50.15018w 1652.7867811.410.50.15060all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 17640.8431921.5250.00.0202100 Floors 2019-Feb-07 16:40:25 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W 19A-38bscp: Part floor, carpet flr fnsh, r-38 ins, frm flr, 12" thkns 12241.8938.00.029646 2250.35 21A-24c: Bg floor, heavy dry or light damp soil, 6' depth, carpet flr fnsh 013301.9000.025700 0 21A-32c: Bg floor, heavy dry or light damp soil, 4' depth, carpet flr fnsh 011461.5200.020754 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 16:40:25 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Project Summary 2/7/19Date:Entire House By: Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F70 Inside db °F75 Design TD °F76 Design TD °F14Daily range H Relative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh32790 Structure Btuh8880 Ducts Btuh0 Ducts Btuh0Central vent (57 cfm)4012 Btuh Central vent (57 cfm)Btuh739 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh36802 Use manufacturer's data n Rate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh9042 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh-865 Ducts Btuh0Central vent (57 cfm)Btuh-1027 CoolingHeating Outside air21002100Area (ft²)Equipment latent load Btuh0 1803818038Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh9042 Equiv. AVF (cfm)4896 Req. total capacity at 0.70 SHR ton1.1 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg.Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMSS960603BN Cond GSX130301BAHRI ref 7365096 Coil CAPF3030D6D AHRI ref 4355516Efficiency96.1 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh60000 Sensible cooling Btuh19880Heating output Btuh58000 Latent cooling Btuh8520 Temperature rise °F66 Total cooling Btuh28400Actual air flow cfm950 Actual air flow cfm950 Air flow factor cfm/Btuh0.029 Air flow factor cfm/Btuh0.107Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 2019-Feb-07 16:40:25 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:AED Assessment 2/7/19Date:Entire House By: Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 38.6%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 383 Btuh (PFG - 1.3*AFG) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 16:40:25Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Right-J® W or ksheet 2/7/19Date:Entire House By:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Entire House Room2 2 Exposed wall 319.0 ft 26.0 ft 3 Room height 9.9 dft 9.0 heat/coolft 4 Room dimensions ft14.0x12.0 5 Room area 2100.0 f t²168.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.504.50 0.100.10 207 207 932 21 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 753 728 3596 345 0 0 0 0 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 25 0 608 264 0 0 0 0 .WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.504.50 0.100.10 234 234 1053 23 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 426 375 1852 178 0 0 0 0 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 30 0 730 1033 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 21 21 239 58 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.444.44 0.090.09 261 241 1070 22 126 126 567 13 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 20 0 456 372 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 753 707 3493 335 0 0 0 0 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 25 0 608 472 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 21 21 239 58 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.394.39 0.090.09 153 133 584 12 108 88 381 7 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 20 0 456 683 20 0 456 683 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 426 357 1761 169 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 52 0 1265 1790 0 0 0 0 DD metalmetal 0.1500.150 ww 11.4011.40 2.782.78 18 18 200 49 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 2100 2100 3192 1764 168 168 255 141 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 646 646 1224 225 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 700 700 1330 0 168 168 319 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 754 754 1146 0 0 0 0 0 6 c) AED excursion 383 247 Envelope loss/gain 26033 8257 1979 1090 12 a)Infiltration 6757 622 310 29 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)32790 8880 2289 1119 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 32790 8880 2289 1119 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 32790 8880 2289 1119 Air required (cfm)Air required (cfm)950 950 66 120 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 16:40:25Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Right-J® W or ksheet 2/7/19Date:Entire House By:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room3 Room5 2 Exposed wall 5.0 ft 8.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.0x5.0 ft8.0x9.0 5 Room area 55.0 f t²72.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.504.50 0.100.10 0 0 0 0 72 72 324 7 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 0 0 0 0 .WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.504.50 0.100.10 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.444.44 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.394.39 0.090.09 45 45 203 4 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 55 55 84 46 72 72 109 60 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 55 55 104 0 72 72 137 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -6 -8 Envelope loss/gain 391 45 570 60 12 a)Infiltration 60 5 95 9 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)450 50 666 69 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 450 50 666 69 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 450 50 666 69 Air required (cfm)Air required (cfm)13 5 19 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 16:40:25Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 3...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Right-J® W or ksheet 2/7/19Date:Entire House By:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room6 Room7 2 Exposed wall 56.0 ft 114.0 ft 3 Room height 9.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft405.0x1.0 ft646.0x1.0 5 Room area 405.0 f t²646.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.504.50 0.100.10 135 135 608 13 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 492 467 2307 222 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 25 0 608 264 .WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.504.50 0.100.10 234 234 1053 23 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 192 141 697 67 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 30 0 730 1033 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 21 21 239 58 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.444.44 0.090.09 135 115 503 10 0 0 0 0 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 20 0 456 372 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 492 471 2327 223 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 21 21 239 58 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.394.39 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 192 163 803 77 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 12 0 292 413 DD metalmetal 0.1500.150 ww 11.4011.40 2.782.78 0 0 0 0 18 18 200 49 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 405 405 616 340 646 646 982 543 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 646 646 1224 225 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 405 405 769 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 24 -361 Envelope loss/gain 4005 782 10647 2871 12 a)Infiltration 668 62 3263 301 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)4672 844 13909 3171 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 4672 844 13909 3171 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 4672 844 13909 3171 Air required (cfm)Air required (cfm)135 90 403 339 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 16:40:25Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 4...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Right-J® W or ksheet 2/7/19Date:Entire House By:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room10 Room11 2 Exposed wall 25.0 ft 27.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft12.0x13.0 ft14.0x13.0 5 Room area 156.0 f t²182.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.504.50 0.100.10 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 126 126 622 60 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 0 0 0 0 .WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.504.50 0.100.10 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.444.44 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 108 108 534 51 0 0 0 0 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.394.39 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 117 97 479 46 117 97 479 46 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 20 0 486 688 20 0 486 688 DD metalmetal 0.1500.150 ww 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 156 156 237 131 182 182 277 153 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 156 156 237 0 182 182 277 0 6 c) AED excursion 238 234 Envelope loss/gain 1973 1154 2141 1181 12 a)Infiltration 537 49 580 53 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2510 1204 2721 1235 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 172 22 0 0 14 Subtotal 2682 1226 2721 1235 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2682 1226 2721 1235 Air required (cfm)Air required (cfm)78 131 79 132 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 16:40:25Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 5...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Right-J® W or ksheet 2/7/19Date:Entire House By:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room12 Room13 2 Exposed wall 5.0 ft 28.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.0x8.0 ft226.0x1.0 5 Room area 40.0 f t²226.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.504.50 0.100.10 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 0 0 0 0 .WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.504.50 0.100.10 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 144 144 711 68 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.444.44 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 45 45 222 21 108 83 410 39 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 25 0 608 472 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.394.39 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 40 40 61 34 226 226 344 190 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 40 40 61 0 226 226 344 0 6 c) AED excursion -7 52 Envelope loss/gain 344 48 2416 821 12 a)Infiltration 107 10 601 55 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)451 58 3017 876 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -451 -58 279 36 14 Subtotal 0 0 3297 912 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 3297 912 Air required (cfm)Air required (cfm)0 0 96 98 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 16:40:25Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 6...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Right-J® W or ksheet 2/7/19Date:Entire House By:Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room14 Room15 2 Exposed wall 18.0 ft 7.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft8.0x10.0 ft7.0x10.0 5 Room area 80.0 f t²70.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-415B19-0wc-4 0.0690.069 nn 4.504.50 0.100.10 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 72 72 356 34 63 63 311 30 .GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 0 0 0 0 .WW 15B19-0wc-415B19-0wc-4 0.0690.069 ee 4.504.50 0.100.10 0 0 0 0 0 0 0 0 1 1 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 90 90 445 43 0 0 0 0 GG 61C61C 0.3200.320 ee 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ee 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ss 4.444.44 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ss 22.8022.80 18.6018.60 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-415B19-0wc-4 0.0690.069 ww 4.394.39 0.090.09 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 ww 22.8022.80 34.1434.14 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 24.3224.32 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 80 80 122 67 70 70 106 59 FF 19A-38bscp19A-38bscp 0.0290.029 --1.891.89 0.350.35 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 21A-32c21A-32c 0.0200.020 --1.521.52 0.000.00 80 80 122 0 70 70 106 0 6 c) AED excursion -18 -10 Envelope loss/gain 1043 126 524 78 12 a)Infiltration 386 36 150 14 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1430 161 674 92 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1430 161 674 92 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1430 161 674 92 Air required (cfm)Air required (cfm)41 17 20 10 Job #: SF1B8 Performed for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing, Heating, and Electric P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 73 Page 1 Righ t-Su it e® Unive rs al 20 18 18.0.19 RSU20477 2019-Feb-07 16:40:50 ...re\Kartchner\SF1B8 davenport.rup N Upper Room10 Room11 Room12 Room13 Room14 Room15 41 cfm 41 cfm 49 cfm 49 cfm 131 cfm 132 cfm 20 cfm 180 cfm 249 cfm Job #: SF1B8 Performed for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing, Heating, and Electric P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 73 Page 2 Righ t-Su it e® Unive r s al 20 18 18.0.19 RSU20477 2019-Feb-07 16:40:50 ...re\Kartchner\SF1B8 davenport.rup N Main Room7 81 cfm 81 cfm 81 cfm 81 cfm 81 cfm Job #: SF1B8 Performed for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing, Heating, and Electric P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 73 Page 3 Righ t-Su it e® Unive rs al 20 18 18.0.19 RSU20477 2019-Feb-07 16:40:50 ...re\Kartchner\SF1B8 davenport.rup N Lower Room2 Room3 Room4 Room5 Room6 60 cfm 68 cfm 60 cfm 13 cfm 19 cfm 68 cfm 576 cfm 14x3.25 12 x 8 6 " 6 " 6 " 6 " 20 x 8 12 x 8 6 " 6 " 6 "6 " 6 " 6 " 8 " 6 " 6 " 20 x 8 5-14x3.25 20 x 8 6 " 20 x 8 2-14x3.25 12 x 8 2019-Feb-07 16:40:26 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W SF1B8Job:Duct System Summary 2/7/19Date:Entire House By: Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.39in H2O0.39 Available static pressure in H2O0.31in H2O0.31 Supply / return available pressure 0.151 / 0.159 in H2O in H2O0.151 / 0.159 Lowest friction rate in/100ft0.055in/100ft0.055 Actual air flow cfm950cfm950 Total effective length (TEL)ft563 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk 00ShMt0x000131781226cRoom10 st11265.08.5ShMt0x08.00.055132791235cRoom11 st7165.036.6ShMt0x06.00.0754948456cRoom13-B st7205.043.3ShMt0x06.00.0614948456cRoom13-C st7175.026.3ShMt0x06.00.07517411430hRoom14-A st7205.023.0ShMt0x06.00.0661020674hRoom15 00ShMt0x0006033559cRoom2 st7175.032.3ShMt0x06.00.0736033559cRoom2-A st2190.013.0ShMt0x06.00.074513450hRoom3 st1175.012.0ShMt0x06.00.081719666hRoom5 st7205.040.5ShMt0x06.00.06145682336hRoom6 st7160.034.0ShMt0x06.00.07845682336hRoom6-A st7170.034.8ShMt0x06.00.07468812782hRoom7 st7150.039.8ShMt0x06.00.07968812782hRoom7-A st2190.06.0ShMt0x06.00.07768812782hRoom7-B 00ShMt0x0006881634hRoom7-C st7150.038.5ShMt0x06.00.08068812782hRoom7-D Bold/italic values have been manually overridden 2019-Feb-07 16:40:26 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...ts\wrightsoftware\Kartchner\SF1B8 davenport.rup Calc = MJ8 Front Door faces: W Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 586 486 0.061 527 12.5 20x8 ShtMetl st2 Peak AVF 172 205 0.055 308 8.6 12x8 ShtMetl st11 Peak AVF 79 132 0.055 198 7.3 12x8 ShtMetl st2 st7 Peak AVF 567 478 0.061 510 12.3 20x8 ShtMetl st1 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb2 0x 1250 180 172.0 0.093 285 7.4 2-3.25x14 2-10x18 SJSp rt2 rb4 0x 410 17 186.0 0.086 131 4.3 3.25x14 10x9 SJSp rt2 rb1 0x 5760 504 289.0 0.055 365 12.6 5-3.25x14 5-10x46 SJSp rt2 rb3 0x 2070 249 0 0 787 0 3.25x14 10x9 SJSp Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 743 701 0.055 669 13.9 20x8 ShtMetl rt2 Peak AVF 743 701 0.055 669 13.9 20x8 ShtMetl rt1