HomeMy WebLinkAboutPROJECT INFO - 19-00037 - 892 Larch Dr - New SFRCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Load Short Form Date:basement VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) Semi-tightConstruction quality7568Inside db (°F) 0Fireplaces1474Design TD (°F) H-Daily range 5050Inside humidity (%) -3157Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Goodman Mfg. Trade LENNOX Trade GOODMAN; JANITROL; AMANA DISTI... Model ML195UH045XP24B-*Cond GSX130181E AHRI ref 4805337 Coil ACNF18XX16D AHRI ref 5039733 Efficiency 95 AFUE Efficiency 10.8 EER, 13 SEER Heating input Btuh44000 Sensible cooling Btuh11760 Heating output Btuh41000 Latent cooling Btuh5040 Temperature rise °F99 Total cooling Btuh16800 Actual air flow cfm450 Actual air flow cfm450 Air flow factor cfm/Btuh0.054 Air flow factor cfm/Btuh0.307 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room1 192 1477 143 80 44 Room2 174 1505 695 82 214 Room3 607 3087 556 168 171 Room4 84 374 12 20 4 Room5 240 1842 58 100 18 basement d 1297 8285 1465 450 450 Other equip loads 3193 604 Equip. @ 0.94 RSM 1945 Latent cooling 0 TOTALS 1297 11478 1945 450 450 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Load Short Form Date:Main/ upstairs VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) Semi-tightConstruction quality7568Inside db (°F) 0Fireplaces1474Design TD (°F) H-Daily range 5050Inside humidity (%) -3157Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Goodman Mfg. Trade LENNOX Trade GOODMAN; JANITROL; AMANA DISTI... Model ML195UH070XP36B-*Cond GSX130301B AHRI ref 4805339 Coil CACF3030N6D+A*EC960302BNA AHRI ref 7365372 Efficiency 95 AFUE Efficiency 11.5 EER, 13.5 SEER Heating input Btuh66000 Sensible cooling Btuh19600 Heating output Btuh64000 Latent cooling Btuh8400 Temperature rise °F81 Total cooling Btuh28000 Actual air flow cfm850 Actual air flow cfm850 Air flow factor cfm/Btuh0.036 Air flow factor cfm/Btuh0.106 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room7 224 2498 577 89 61 Room8 144 1804 975 64 104 Room9 498 4253 1245 152 133 Room10 77 315 28 11 3 Room11 30 270 24 10 3 Room12 312 3496 1003 125 107 Room13 210 2494 540 89 58 Room14 186 2098 1153 75 123 Room15 60 359 69 13 7 Room16 144 2049 766 73 82 Room18 516 4187 1602 149 171 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 3 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S Main/ upstairs d 2401 23824 7983 850 850 Other equip loads 0 0 Equip. @ 0.94 RSM 7504 Latent cooling 0 TOTALS 2401 23824 7504 850 850 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Building Analysis Date:basement VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) Semi-tightConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 38.444033.5Walls 9.9113723.7Glazing 000Doors 1.82041.5Ceilings 18.421121.61.6Floors 3.74301.7Infiltration 00Ducts 00Piping 00Humidification 27.83193Ventilation0Adjustments 100.011478Total Cooling Other Glazing Ceilings Infiltration Ventilation % of loadBtuhBtuh/ft²Component 1.7360.0Walls 61.4127026.5Glazing 000Doors 5.61160.8Ceilings 000Floors 2.1430.2Infiltration 00Ducts 29.2604Ventilation 00Internal gains 00Blower 0Adjustments 100.02069Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 37 Btuh/ft²-°F WARNING: window to floor area ratio = 3.7% - less than 5%. 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Building Analysis Date:Main/ upstairs VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) Semi-tightConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Infiltration % of loadBtuhBtuh/ft²Component 41.498614.8Walls 28.2672023.7Glazing 2.046611.1Doors 9.121621.5Ceilings 1.94621.61.6Floors 17.441511.7Infiltration 00Ducts 00Piping 00Humidification 00Ventilation0Adjustments 100.023824Total Cooling Walls Glazing Other Ceilings Infiltration % of loadBtuhBtuh/ft²Component 12.29730.5Walls 65.8525318.5Glazing 1.51172.8Doors 15.412270.8Ceilings 000Floors 5.24130.2Infiltration 00Ducts 00Ventilation 00Internal gains 00Blower 0Adjustments 100.07983Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 65 Btuh/ft²-°F Data entries checked. 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Component Constructions Date:basement VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) Semi-tightConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B19-0wc-6: Bg wall, heavy dry or light damp soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh 80.0311093.4619.00.043320n 80.0311093.4619.00.043320e 100.0310773.5419.00.043304s 80.0311093.4619.00.043320w 360.0344033.4819.00.0431264all Partitions (none) Windows 61C: ul .31 shgc .35 16910.637923.700.32016n 55134.437923.700.32016e 55134.437923.700.32016w 127026.5113723.700.32048all Doors (none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 1160.842041.4850.00.020138 Floors 21A-28c: Bg floor, heavy dry or light damp soil, 6.5' depth, carpet flr fnsh 0021121.6300.0221297 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Component Constructions Date:Main/ upstairs VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) SimplifiedMethod)H(34-Da ily ra nge (°F) Semi-tightConstruction quality60-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1940.4719634.8122.00.065408n 2910.4729534.8122.00.065614e 2170.4721984.8122.00.065457s 2710.4727474.8122.00.065571w 9730.4798614.8122.00.0652050all Partitions (none) Windows 61C: ul .31 shgc .35 143310.6321623.700.320136n 172134.4118423.700.32050e 154818.9194223.700.32082s 55134.437923.700.32016w 525318.5672023.700.320284all Doors metal: Door, mtl pur core type 582.7823311.110.50.15021s 582.7823311.110.50.15021w 1172.7846611.110.50.15042all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 12270.8421621.4850.00.0201461 Floors 21A-28c: Bg floor, heavy dry or light damp soil, 6.5' depth, carpet flr fnsh 001301.6300.02280 003321.6300.022204 004621.6300.022284all Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Project Summary Date:basement VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F68 Inside db °F75 Design TD °F74 Design TD °F14Daily range H Relative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh8285 Structure Btuh1465 Ducts Btuh0 Ducts Btuh0Central vent (47 cfm)3193 Btuh Central vent (47 cfm)Btuh604 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh11478 Use manufacturer's data n Rate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh1945 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight0Fireplaces Structure Btuh-59 Ducts Btuh0Central vent (47 cfm)Btuh-840 CoolingHeating Outside air12971297Area (ft²)Equipment latent load Btuh0 19461946Volume (ft³)Air changes/hour 0.100.19 Equipment Total Load (Sen+Lat)Btuh1945 Equiv. AVF (cfm)36 Req. total capacity at 0.70 SHR ton0.2 Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Goodman Mfg.Trade LENNOX Trade GOODMAN; JANITROL; AMANA DISTI... Model ML195UH045XP24B-*Cond GSX130181EAHRI ref 4805337 Coil ACNF18XX16D AHRI ref 5039733Efficiency95 AFUE Efficiency 10.8 EER, 13 SEER Heating input Btuh44000 Sensible cooling Btuh11760Heating output Btuh41000 Latent cooling Btuh5040 Temperature rise °F99 Total cooling Btuh16800Actual air flow cfm450 Actual air flow cfm450 Air flow factor cfm/Btuh0.054 Air flow factor cfm/Btuh0.307Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Project Summary Date:Main/ upstairs VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F68 Inside db °F75 Design TD °F74 Design TD °F14Daily range H Relative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh23824 Structure Btuh7983 Ducts Btuh0 Ducts Btuh0Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh23824 Use manufacturer's data n Rate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh7504 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight0Fireplaces Structure Btuh-575 Ducts Btuh0Central vent (0 cfm)Btuh0 CoolingHeating (none)24012401Area (ft²)Equipment latent load Btuh0 1920819208Volume (ft³)Air changes/hour 0.100.19 Equipment Total Load (Sen+Lat)Btuh7504 Equiv. AVF (cfm)3261 Req. total capacity at 0.70 SHR ton0.9 Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Goodman Mfg.Trade LENNOX Trade GOODMAN; JANITROL; AMANA DISTI... Model ML195UH070XP36B-*Cond GSX130301BAHRI ref 4805339 Coil CACF3030N6D+A*EC960302BNA AHRI ref 7365372Efficiency95 AFUE Efficiency 11.5 EER, 13.5 SEER Heating input Btuh66000 Sensible cooling Btuh19600Heating output Btuh64000 Latent cooling Btuh8400 Temperature rise °F81 Total cooling Btuh28000Actual air flow cfm850 Actual air flow cfm850 Air flow factor cfm/Btuh0.036 Air flow factor cfm/Btuh0.106Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:AED Assessment Date:basement VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 200 400 600 800 1,000 1,200 1,400 1,600 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 26.8%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2019-Jan-04 15:28:16 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:AED Assessment Date:Main/ upstairs VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Design Conditions Location:CoolingHeatingIndoor: 7568Indoor temp era ture (°F)Idaho Falls, ID, US 1474Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude: Outdoor:-31.557.0Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bul b (°F) )H(34-Da ily ra nge (°F) 60-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 26.8%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Right-J® W or ksheet Date:basement VinceBy:Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name basement Room1 2 Exposed wall 164.0 ft 28.0 ft 3 Room height 8.0 dft 8.0 heat/coolft 4 Room dimensions ft12.0x16.0 5 Room area 1297.0 f t²192.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 3.463.46 0.030.03 336 320 1109 8 128 112 372 1 .GG 61C61C 0.3200.320 nn 23.6823.68 10.5610.56 16 0 379 169 16 0 379 169 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 3.463.46 0.030.03 336 320 1109 8 0 0 0 0 GG 61C61C 0.3200.320 ee 23.6823.68 34.4234.42 16 0 379 551 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 3.543.54 0.030.03 304 304 1077 10 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ww 3.463.46 0.030.03 336 320 1109 8 96 96 340 3 GG 61C61C 0.3200.320 ww 23.6823.68 34.4234.42 16 0 379 551 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 138 138 204 116 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 1297 1297 2112 0 192 192 313 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 -38 Envelope loss/gain 7855 1422 1403 136 12 a)Infiltration 430 43 73 7 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)8285 1465 1477 143 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 8285 1465 1477 143 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 8285 1465 1477 143 Air required (cfm)Air required (cfm)450 450 80 44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Right-J® W or ksheet Date:basement VinceBy:Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room2 Room3 2 Exposed wall 29.0 ft 56.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft174.0x1.0 ft607.0x1.0 5 Room area 174.0 f t²607.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 3.463.46 0.030.03 0 0 0 0 208 208 737 7 .GG 61C61C 0.3200.320 nn 23.6823.68 10.5610.56 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 3.463.46 0.030.03 0 0 0 0 184 168 570 3 GG 61C61C 0.3200.320 ee 23.6823.68 34.4234.42 0 0 0 0 16 0 379 551 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 3.543.54 0.030.03 144 144 510 5 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ww 3.463.46 0.030.03 88 72 230 0 56 56 198 2 GG 61C61C 0.3200.320 ww 23.6823.68 34.4234.42 16 0 379 551 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 18 18 27 15 46 46 68 39 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 174 174 283 0 607 607 988 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 117 -61 Envelope loss/gain 1429 688 2941 541 12 a)Infiltration 76 8 147 15 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1505 695 3087 556 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1505 695 3087 556 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1505 695 3087 556 Air required (cfm)Air required (cfm)82 214 168 171 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 3...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Right-J® W or ksheet Date:basement VinceBy:Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room4 Room5 2 Exposed wall 7.0 ft 44.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft7.0x12.0 ft12.0x20.0 5 Room area 84.0 f t²240.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 3.463.46 0.030.03 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 23.6823.68 10.5610.56 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 1 1 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 3.463.46 0.030.03 56 56 198 2 96 96 340 3 GG 61C61C 0.3200.320 ee 23.6823.68 34.4234.42 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 3.543.54 0.030.03 0 0 0 0 160 160 567 5 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ww 3.463.46 0.030.03 0 0 0 0 96 96 340 3 GG 61C61C 0.3200.320 ww 23.6823.68 34.4234.42 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 14 14 21 12 60 60 89 50 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 84 84 137 0 240 240 391 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -3 -15 Envelope loss/gain 356 10 1727 47 12 a)Infiltration 18 2 115 11 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)374 12 1842 58 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 374 12 1842 58 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 374 12 1842 58 Air required (cfm)Air required (cfm)20 4 100 18 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 4...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Right-J® W or ksheet Date:Main/ upstairs VinceBy:Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Main/ upstairs Room7 2 Exposed wall 297.0 ft 30.0 ft 3 Room height 8.0 dft 8.0 heat/coolft 4 Room dimensions ft14.0x16.0 5 Room area 2401.0 f t²224.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 544 408 1963 194 128 98 471 47 .GG 61C61C 0.3200.320 nn 23.6823.68 10.5610.56 136 0 3216 1433 30 0 710 317 1 1 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 664 614 2953 291 0 0 0 0 GG 61C61C 0.3200.320 ee 23.6823.68 34.4234.42 50 0 1184 1721 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 560 457 2198 217 0 0 0 0 GG 61C61C 0.3200.320 ss 23.6823.68 18.8818.88 82 0 1942 1548 0 0 0 0 DD metalmetal 0.1500.150 ss 11.1011.10 2.782.78 21 21 233 58 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 608 571 2747 271 112 112 539 53 GG 61C61C 0.3200.320 ww 23.6823.68 34.4234.42 16 0 379 551 0 0 0 0 DD metalmetal 0.1500.150 ww 11.1011.10 2.782.78 21 21 233 58 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 1461 1461 2162 1227 210 210 311 176 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 80 80 130 0 29 29 47 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 204 204 332 0 0 0 0 0 6 c) AED excursion 0 -58 Envelope loss/gain 19673 7570 2079 535 12 a)Infiltration 4151 413 419 42 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)23824 7983 2498 577 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 23824 7983 2498 577 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 23824 7983 2498 577 Air required (cfm)Air required (cfm)850 850 89 61 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 5...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Right-J® W or ksheet Date:Main/ upstairs VinceBy:Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room8 Room9 2 Exposed wall 25.0 ft 48.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft9.0x16.0 ft498.0x1.0 5 Room area 144.0 f t²498.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 0 0 0 0 200 119 573 57 .GG 61C61C 0.3200.320 nn 23.6823.68 10.5610.56 0 0 0 0 81 0 1913 853 1 1 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 0 0 0 0 184 175 842 83 GG 61C61C 0.3200.320 ee 23.6823.68 34.4234.42 0 0 0 0 9 0 213 310 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 128 128 616 61 0 0 0 0 GG 61C61C 0.3200.320 ss 23.6823.68 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 72 56 269 27 0 0 0 0 GG 61C61C 0.3200.320 ww 23.6823.68 34.4234.42 16 0 379 551 0 0 0 0 DD metalmetal 0.1500.150 ww 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 119 119 176 100 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 9 9 15 0 25 25 41 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 202 -124 Envelope loss/gain 1455 940 3582 1178 12 a)Infiltration 349 35 671 67 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1804 975 4253 1245 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1804 975 4253 1245 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1804 975 4253 1245 Air required (cfm)Air required (cfm)64 104 152 133 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 6...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Right-J® W or ksheet Date:Main/ upstairs VinceBy:Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room10 Room11 2 Exposed wall 6.0 ft 5.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft7.0x11.0 ft5.0x6.0 5 Room area 77.0 f t²30.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 23.6823.68 10.5610.56 0 0 0 0 0 0 0 0 1 1 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 23.6823.68 34.4234.42 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 48 48 231 23 0 0 0 0 GG 61C61C 0.3200.320 ss 23.6823.68 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 0 0 0 0 40 40 192 19 GG 61C61C 0.3200.320 ww 23.6823.68 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 5 5 8 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -3 -2 Envelope loss/gain 231 20 201 17 12 a)Infiltration 84 8 70 7 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)315 28 270 24 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 315 28 270 24 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 315 28 270 24 Air required (cfm)Air required (cfm)11 3 10 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 7...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Right-J® W or ksheet Date:Main/ upstairs VinceBy:Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room12 Room13 2 Exposed wall 50.0 ft 32.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft312.0x1.0 ft210.0x1.0 5 Room area 312.0 f t²210.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 0 0 0 0 160 135 649 64 .GG 61C61C 0.3200.320 nn 23.6823.68 10.5610.56 0 0 0 0 25 0 592 264 1 1 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 144 144 693 68 0 0 0 0 GG 61C61C 0.3200.320 ee 23.6823.68 34.4234.42 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 152 101 486 48 0 0 0 0 GG 61C61C 0.3200.320 ss 23.6823.68 18.8818.88 30 0 710 566 0 0 0 0 DD metalmetal 0.1500.150 ss 11.1011.10 2.782.78 21 21 233 58 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 104 83 399 39 96 96 462 46 GG 61C61C 0.3200.320 ww 23.6823.68 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 11.1011.10 2.782.78 21 21 233 58 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 16 16 24 13 210 210 311 176 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 12 12 20 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 20 20 33 0 6 c) AED excursion 82 -54 Envelope loss/gain 2797 933 2046 496 12 a)Infiltration 699 70 447 45 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)3496 1003 2494 540 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 3496 1003 2494 540 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 3496 1003 2494 540 Air required (cfm)Air required (cfm)125 107 89 58 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 8...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Right-J® W or ksheet Date:Main/ upstairs VinceBy:Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room14 Room15 2 Exposed wall 25.0 ft 5.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft186.0x1.0 ft5.0x12.0 5 Room area 186.0 f t²60.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 56 56 269 27 0 0 0 0 .GG 61C61C 0.3200.320 nn 23.6823.68 10.5610.56 0 0 0 0 0 0 0 0 1 1 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 144 119 572 56 40 40 192 19 GG 61C61C 0.3200.320 ee 23.6823.68 34.4234.42 25 0 592 861 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ss 23.6823.68 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 23.6823.68 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 186 186 275 156 60 60 89 50 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 24 24 39 0 5 5 8 0 6 c) AED excursion 19 -7 Envelope loss/gain 1748 1119 289 62 12 a)Infiltration 349 35 70 7 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2098 1153 359 69 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2098 1153 359 69 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2098 1153 359 69 Air required (cfm)Air required (cfm)75 123 13 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-04 15:28:16Right-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 9...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Right-J® W or ksheet Date:Main/ upstairs VinceBy:Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 1 Room name Room16 Room18 2 Exposed wall 26.0 ft 45.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft12.0x12.0 ft516.0x1.0 5 Room area 144.0 f t²516.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.814.81 0.470.47 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nn 23.6823.68 10.5610.56 0 0 0 0 0 0 0 0 1 1 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.814.81 0.470.47 96 96 462 46 56 40 192 19 GG 61C61C 0.3200.320 ee 23.6823.68 34.4234.42 0 0 0 0 16 0 379 551 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.814.81 0.470.47 96 72 346 34 136 108 519 51 GG 61C61C 0.3200.320 ss 23.6823.68 18.8818.88 24 0 568 453 28 0 663 529 DD metalmetal 0.1500.150 ss 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG 61C61C 0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.814.81 0.470.47 16 16 77 8 168 168 808 80 GG 61C61C 0.3200.320 ww 23.6823.68 34.4234.42 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ww 11.1011.10 2.782.78 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.481.48 0.840.84 144 144 213 121 516 516 764 433 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.631.63 0.000.00 12 12 20 0 143 143 233 0 6 c) AED excursion 69 -124 Envelope loss/gain 1686 730 3558 1539 12 a)Infiltration 363 36 629 63 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2049 766 4187 1602 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2049 766 4187 1602 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2049 766 4187 1602 Air required (cfm)Air required (cfm)73 82 149 171 Job #: SI309 Performed by Vince for: Katchner 601 West 1700 South Logan, Utah 84321 Phone: 435-755-7080 Scale: 1 : 72 Page 1 Righ t-Su it e® Unive rsa l 2 0 18 18.0.19 RSU20477 2019-Jan-04 15:28:38 ...\SI309 ashland with basement.rup N basement Room1 Room2 Room3 Room4 Room5 Room6 384 cfm 85 cfm 80 cfm 100 cfm 80 cfm 214 cfm 85 cfm 20 cfm 100 cfm 20 cfm 6 " 2-14x3.25 14x3.25 12 x 8 6 " 12 x 8 6 " 6 " 6 " 14x3.25 12 x 8 12 x 8 12 x 8 Job #: SI309 Performed by Vince for: Katchner 601 West 1700 South Logan, Utah 84321 Phone: 435-755-7080 Scale: 1 : 72 Page 2 Righ t-Su it e® Unive r sa l 2 0 18 18.0.19 RSU20477 2019-Jan-04 15:28:38 ...\SI309 ashland with basement.rup N Main Room7 Room8 Room9 Room10 Room11 Room12 62 cfm 165 cfm 163 cfm 134 cfm 45 cfm 76 cfm 11 cfm 10 cfm 62 cfm 45 cfm 104 cfm 76 cfm Job #: SI309 Performed by Vince for: Katchner 601 West 1700 South Logan, Utah 84321 Phone: 435-755-7080 Scale: 1 : 72 Page 3 Righ t-Su it e® Unive rsa l 2 0 18 18.0.19 RSU20477 2019-Jan-04 15:28:38 ...\SI309 ashland with basement.rup N 2nd floor Room13 Room14 Room15 Room16 Room17 Room18 6 " 44 cfm 89 cfm 85 cfm 93 cfm 208 cfm 85 cfm 44 cfm 123 cfm 13 cfm 82 cfm 82 cfm 5 " 6 " 14x3.25 5 x 84 x 8 14x3.252-14x3.25 7 "14x3.25 6 " 14x3.25 5 "6 " 4 " 4 " 6 " 5 " 6 " 6 " 7 " 4 " 6 " 20 x 8 14x3.25 20 x 8 2019-Jan-04 15:28:18 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 1 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Duct System Summary Date:basement VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.30in H2O0.30 Available static pressure in H2O0.40in H2O0.40 Supply / return available pressure 0.202 / 0.198 in H2O in H2O0.202 / 0.198 Lowest friction rate in/100ft0.088in/100ft0.088 Actual air flow cfm450cfm450 Total effective length (TEL)ft453 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st2140.032.0ShMt0x06.00.11844801477hRoom1 st2115.022.0ShMt12x86.00.14821482695cRoom2 st1195.034.0ShMt0x06.00.0888584278cRoom3 st1180.021.0ShMt0x06.00.1018584278cRoom3-A st1190.014.0ShMt0x06.00.099420374hRoom4 st1185.027.0ShMt0x06.00.095181001842hRoom5 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 288 192 0.088 432 7.8 12x8 ShtMetl st2 Peak AVF 162 258 0.118 386 6.0 12x8 ShtMetl Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 200 4 65.0 0.304 64 2.6 3.25x14 10x9 SJSp rb8 0x 1000 18 150.0 0.132 150 5.9 x8 12 ShMt rb6 0x 2490 384 141.0 0.140 608 9.0 2-3.25x14 2-10x18 SJSp rt2 rb7 0x 800 44 224.0 0.088 254 5.5 3.25x14 10x9 SJSp rt2 2019-Jan-04 15:28:18 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 2 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt2 Peak AVF 330 428 0.088 642 8.9 12x8 ShtMetl 2019-Jan-04 15:28:18 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 3 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S SI309Job:Duct System Summary Date:Main/ upstairs VinceBy: Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.34in H2O0.34 Available static pressure in H2O0.36in H2O0.36 Supply / return available pressure 0.164 / 0.196 in H2O in H2O0.164 / 0.196 Lowest friction rate in/100ft0.061in/100ft0.061 Actual air flow cfm850cfm850 Total effective length (TEL)ft595 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st3175.03.0ShMt0x04.00.092311315hRoom10 st3200.019.0ShMt0x04.00.075310270hRoom11 st3215.037.0ShMt0x06.00.06553621748hRoom12 st3210.029.0ShMt0x06.00.06953621748hRoom12-A st3195.029.0ShMt0x05.00.07329441247hRoom13 st3185.025.0ShMt0x05.00.07829441247hRoom13-A st3235.036.0ShMt0x07.00.061123751153cRoom14 st3230.025.0ShMt0x04.00.064713359hRoom15 st3220.039.0ShMt0x06.00.0638273766cRoom16 st3180.018.0ShMt0x06.00.0838575801cRoom18 st3205.027.0ShMt0x06.00.0718575801cRoom18-A 00ShMt0x0003145288hRoom7 st4180.022.0ShMt0x05.00.08131451249hRoom7-A st5115.015.0ShMt0x06.00.12610464975cRoom8 st3225.040.0ShMt0x06.00.06266762127hRoom9 st3190.026.0ShMt0x06.00.07666762127hRoom9-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 697 685 0.061 627 13.3 20x8 ShtMetl st4 Peak AVF 109 135 0.081 484 6.8 5x8 ShtMetl st5 Peak AVF 64 104 0.126 467 5.6 4x8 ShtMetl st4 2019-Jan-04 15:28:18 Rig ht-Su ite® U niv er sal 20 18 18 .0.19 RSU2 0477 Page 4 ...tware\Kartchner\SI309 ashland with basement.rup Calc = MJ8 Front Door faces: S Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb13 0x 1530 165 68.0 0.288 618 7.0 x0 0 ShMt rb14 0x 1630 136 89.0 0.220 516 6.0 3.25x14 10x9 SJSp rt3 rb2 0x 730 82 324.0 0.061 258 6.0 3.25x14 10x9 SJSp rt3 rb10 0x 890 58 167.0 0.117 282 5.4 3.25x14 10x9 SJSp rt3 rb12 0x 1500 208 239.0 0.082 329 8.0 2-3.25x14 2-10x18 SJSp rt3 rb15 0x 1340 109 244.0 0.080 425 6.8 3.25x14 10x9 SJSp rt3 rb11 0x 880 93 315.0 0.062 293 6.2 3.25x14 10x9 SJSp rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt3 Peak AVF 697 685 0.061 627 13.3 20x8 ShtMetl