HomeMy WebLinkAboutENGINEERING CALCULATIONS - 08-00033 - Johnson Precast ShopDesign: Intelligence, LLC
Engineering Calculations Summary
Date: December 27, 2007
Subject: Johnson Shop, Rexburg, Madison County,
Customer: Mark Johnson
JAN 15 2008 IL
0800033
Johnson Precast Shop
551 E Moody Rd
This analysis uses the Design Criteria
calculations. Jp{1. 5vi&_ ?re_cez,5 {�
Materials: (� S(o - Rq 17
Dimensional Lumber — NDS 1997 design val
Concrete: 2500 psi @ 28 days
Reinforcing Steel - #4 and smaller Grade 40, MA- F naJ ed, CoAce-rrle-d
Assumptions: Gt{�aui �truc( t~ra I lAle31-11Y
IBC 2003 —Foundations designed for Max E St h ce. EX 1-er i o (' C.n U C rt rl it n
IY1SF&�leci — �j�,�
Design Loads:
Roof Live Load (min) — 20 psf during construction
Ground Snow load = 50 psf,
Roof Snow load= 35 psf , I
Snow Load Importance Factor —1.0j
Snow Exposure Factor — 0.9
Wind = 90 mph, Exposure B
Wind Importance Factor— 1.0
Wind Exposure = B
Seismic Design Category — DI
Seismic Use Group - 1
References:
IBC 2003
Customer Drawings
TrusJoist MacMillian Design Guides
Summary:
G01 no4b \�� \( C')-1
SWY S` Al -ILMI-
Dov �nSpe.C�+o�nS 'o.�
All beam sizes and footing sizes are noted on the drawings.
—C 2003 as the basis for the
t�7161
tions and included details are for
nd customer only and not to be
manner without the written
sign Intelligence.
Designed By Scott A S auldin , P.E. I Checked By:
Date: ___
design Intelligence, LLC JOHNSON SHOP
___ _— �,_ REXBURG, MADISON
12/27/2007
Page 1
Design Intelligence, LLC JOHNSON SHOP 12/27/2007
1037 Erikson Dr_ REXBURG, MADISON
Raxhurn Idaho 53440 COUNTY. IDAHO
Page 2
Component and Cladding Design Wind Pressures -Table 1609.6.2.1(2
Roof
Zone Area
< 5:12
5:12
> 5:12
1
10
10
-14.6
10
-13.3
13.3
-14.6
1
20
10
-14.2
10
-13
13
43.8
1
50
10
-13.7
10
-12.5
12.5
-12.8
1
100
10
-13.3
_
10
-12.1
12.1
-12.1
2
10
10
-24.4
10
-28.2
13.3
-17
2
20
10
-21.8
10
-25.6
13
-16.3
_
2
50
10
-18.4
10
-22.1
12.5
-15.3
2
100
10
-15.8
10
-19.5
12.1
-14.6
3
10
10
-36.8
10
-28.2
13.3
-17
3
20
10
-30.5
10
-25.6
13
-16.3
3
50
10
-22.1
10
-22.1
12.5
-15.3
3
100
10
-15.8
10
-19.5
12.1
-14.6
_
Wall
4
10
14.6
-15.8
4
20
13.9
-15.1
_
4
50
13
-14.3
4
100
12.4
-13.6
5
10
14.6
-19.5
5
20
13.9
-18.2
512
13
-16.5
5
100
12.4
-15.1
Roof Overhan Com
onent and Cladding Desi
n Wind Pressures - Table 1609.6.2.1(3)
Zone Area
< 5:12
5:12
> 5:12
2
10
21
-27.2
-24.7
2
20
-20.6
-27.2
-24
2
50
-20.1
-27.2
-23
2
100
-19.8
-27.2
-22.2
3
10
-34.6
-45.7
3
20
-27.1
-40.5
-24
3
50
-17.3
33.6
-23
3
100
-10
-28.4
-22.2
1609.6.2.1(4) Height and Exposure Adjustment Coefficient =
1
Page 2
Design Intelligence, LLC JOHNSON SHOP
1037 Erikson Dr. REXBURG. MADISON
r _..ti...
IA -k- AQAAn CAUNTY. IDAHO
RrihVu
---
-
Seismic
Reference Code - IBC 2003 values for Ss, S1, Fa and Fv are taken
from Code Control CD using Zip Code
1615.1.2.1 Fa
1615.1.2(2 Fv
1615.1 Ss 1.235
1615.1 SI 0.646 g
Fa
Fv
Site Class A - Hard Rock
0.8
0.8
Site iWClass B - Dense Soil or Soft Rock 1
1
1
Site Class C - Stiff Soil
1.2
1.7
Site Class D - Soft Soil _.
1.01
1.59
A B C
= FaSs 0.988 1.235
1 = FvS1 0.5168 0.646
Mit
D
1.482 - 1.24736.
1.0982 1.02714:
s Accel
= 2/3'SMS 0.66196 0.82745
SDI = 2/3'SMI 0.346256 0.43282
0.99204 0.835725
0.735794 0.688.
1616.2 Seismic Use Group 1616.3 seismic Design Category
Group I - Non -Essential Table 1616.3(1)
Table 1616.3(2)
D
D
Seismic Response Coefficient
1617.6 (Table 1617.6) Response Modification Factor R =
1616.2 (Table 1604.5) Occupancy Importance Factor I =
6
1
Basic Fundamental Period
Cit
Steel Moment Resistin Frame 0.035
Reinforced Concrete Moment Resisting Frame 0.03
All Other Building Systems
0.02
Building Height 27 it Table 1617.4.2 Cu
Approximate Fundamental Period
Ta = Ct'hn43/4 = 0.28 sec Ri id Bid
_
Site Class A B
C
D
Cs = SDS/(R/I) = 0.1103 0.1379
0.1655 ` 0.1393----
.1393__Max
MaxCs = SDI/(R/I)T = 0.0164 0.0205
0.0349 0.0326
Min Cs = 0.044SDS'I = 0.0291 0.0364
0.0437 0.0368
Page 3
12/27/2007
Design Intelligence, LLC JOHNSON SHOP
1037 Erikson Dr. REXBURG, MADISON
�_..ti...,. wti.. amen M111NITY. IDAHO
Design Seismic Response Coefficient
Site Class A B
Cs = 0.0291 0.0364
1617.4.1 Equiv Lateral Force Method V = CsW =
1617.5.1 Simplified Approach V = 1.2•(SDS/R)'W =
C D
0.0437: 0.0368
0.0368 W
0.16714 W
Determine Method of Seismic Anal sis
Light Framing Construction Criteria
2308.2.1 Building stories 2
2308.2.2 Bearing wall floor to floor height 9
2308.2.3.1 Average DL 1 15
2308.2.3.2 Floor Live Loads 40
2308.2.3.3 Ground Snow Load 50
2308.2.4 Wind speed 90
2308.2.5 Truss Span _ 30
stories
it
psf
psf
psf
mph
It
IYES
YES
YES
YES
YES
YES
YES
1616.6.1 Simplified Anal a Requirements
T. Does Building meet light frame construction criteria ?
YES
2. Is buildingof an other construction with flexible dia hragms at
eve level as defined in section 1602 ?
YES
Buildingmay use Sim Iified Analysis Method
Page 4
12/27/2007
Design intelligence, LLC JOHNSON SHOP 12/27/2007
1037 Erikson Dr. REXBURG, MADISON
Rexbur , Idaho 83440 COUNTY IDAHO
Type Fb psi Fv psi E psi
STEEL 24000 14400 29000000
LVL 2600 285 1900000
LSL 1700 400 1300000
_
PARALM 2900 290 2000000
GLB 2400 190 1800000
DF 1350 85 1600000
Beam 1 Door Header
TypeI Fb psi jFv psi E psi
LVL 2600 285 1900000
S an = 16 it
Tributary Width = 17 It
Load 1 Load 2 Load 3 Load 4
Pt. Load
Distance
Left Reaction Right Reaction
0 Itis 0 itis
Loads
Snow 35 pelf
Live Load 0 psf
Dead Load 15 psf
Uniform Load =
595 Ibs/ft
0 lbs/ft
255 lbs/ft
Moment
Live Load Moment = 19040 Ib -ft
=
228480 Ib -in
Dead Load Moment = 8160 Ib -ft
=
97920 Ib -in
Point Load Moment = 0 Ib -ft
=
0 Ib -in
Section Modulus Required =
125.54 in3
Section Width = 5.25 in.
Section D7M!!___, = 14 in.
Section Modulus Provided = 171.5
in3
OK
Moment of Ineritia Provided = 1200.5
in4
Deflection
Live Load = 0.38 in.
U360
0.53 in.
OK
Dead Load = 0.16 in.
Total = 0.55 in.
U240
0.8 in.
OK
Horizontal Shear
fv Left = 139 psi OK
fv Right =
139 psi
OK
FV = 285 psi !!!!Uble
a
Reaction Left
Reaction Right
Use 5.26 X
LVL
I
68001bs
6800lbs
Page 5
Design Intelligence, LLC JOHNSON SHOP 12/27/2007
1037 Erikson Dr. REXBURG, MADISON
Rexbur , Idaho 83440 COUNTY, IDAHO
Type Fb psi Fv psi JE psi
STEEL 24000 14400 29000000
LVL 2600 285 1900000
LSL 1700 400 1300000
PARALM 2900 290 2000000
GLB 2400 190 1800000
DF 13501 851 16000001
1
Beam 2 Door Header
Type I Fb psi lFv psi E psi
LVL 2600 285' 1900000
Span = 10 ft
Tributary Width = 17 ;: It
Load 1 Load 2 Load 3 Load 4
Pt. Load
Distance
Left Reaction IRightReaction
0 lbs 0 lbs
Loads
Snow 35 psf
Live Load - 0 psf
Dead Load 15 psf
Uniform Load =
595 Ibs/ft
0 Ibslft
255 lbs/ft
Moment
Live Load Moment = 7438 Ib -ft
=
89250 Ib -in
Dead Load Moment = 3188 ib -ft
=
38250 Ib in
Point Load Moment = 0 1"
=
0 Ib4n
Section Modulus Required -
49.04 in3
Section Width = 5.25 in.
Section Depth = 925
Section Modulus Provided I 74.9
in3
OK
Moment of IneriHa Provided=Kin.
tn4
Deflection
Live Load = 0.20
U360
0.33 in.
OK
Dead Load = 0.09
Total =
0.29 in.
0240
0.5 in.
OK
Horizontal
Shear
fv Left= 131 psi OK
fv Right =
131 Psi
OK
FV = 285 psi Allowable
Reaction Left
Reaction Right
Use 5.25 X 9.25
LVL
j
4250
lbs
I 4250
lbs
Page 6
Design Intelligence, LLC JOHNSON SHOP 12/27/2007
1037 Erikson Dr. REXBURG, MADISON
Rexburg, Idaho 83440 COUNTY, IDAHO
Type Fb psi Fv psi E psi
STEEL 24000 14400 29000000
LVL 2600 285 1900000
LSL 1700 400 1300000
PARALM 2900 290 2000000
GLB 2400 190 1800000
DF 1350 85 1600000
Beam 3 Window Header
Type Fb psi I Fv psi JE psi
DF 1350 85 1600000
ft
Tributary Width = 17 it
Load 1 Load 2 Load 3 Load 4
Pt. Load
Distance
Left Reaction IFFUright Reaction
0 lbs 0 lbs
Loads
Snow 35 psi
Live Load 0 psf _
Dead Load 15 psf
Uniform Load =
595 lbs/ft
0 lbs/ft
255 lbs/ft
Moment
Live Load Moment =
1190 1"
=
14280 Ib -in
Dead Load Moment =
510 Ib -ft
=
6120 Ib -in
Point Load Moment =
0 ib -ft
=
0 Ib -in
Section Modulus Reciuired —
15.11 in3
Section Width = 4.5 in.
Section Depth = 9,25 in.
Section Modulus Provided = 64.2
in3
OK
Moment of Ineritia Provided = 296.8 in4
Deflection
Live Load = 0.01 in.
U360
0.13 in.
OK
Dead Load = 0.00 in.
Total = 0.01 in.
L/240
0.2 in.
OK
Horizontal Shear
tv Left = 61 psi OK
fv Right =
61 psi
OK
FV = 85 si Allowable
Reaction Left
Reaction Rtght
Use 4.5 X 1 9.25
JDF
1700lbs
1700lbs
Page 7
Design Intelligence, LLC JOHNSON SHOP 12/27/2007
1037 Erikson Dr. REXBURG, MADISON
Rex bur , Idaho 83440 COUNTY, IDAHO
Foundation Desi n
Allowable Bearing Capacity
Snow Load
Floor Live Load
Wali Dead Load
Roof Dead Load
Brick Dead Load
Floor Dead Load
1500 psf
35 psf
40 psf
15 psf
15 psf
0 psf
15 psf
Max Roof $pan =
Max Floor Span =
Wali Height =
Stem Wall Height =
Stem Wall Width =
34 it
'Oft
12 ft
7 ft
8 in.
Exterior Bearing Walls - F1
Roof Loads 850 lbs/ft
Floor Loads 0 ibs/ft
Wall Load 180 lbs/ft
Proposed Footing
Width
Depth
16 in
10 in
Stem Wail Load 700 lbs/ft
Footing Load 167 lbs/ft
Total 1897 Ibs/ft
Bearing Pressure = 1423 psf
OK
Reinforcing Requirements
Min Rein rcing Factors
Footing
1 0.002
Stem Wall
Vertical 0.0012
Horizontal 0.002
Reinforcing Bar #4
0.2 Win
Footing
Continuous Reinforcing Count
2 bars
Stem waill I
Continuous Reinforcing Count
7 1 bars
Vertical - Reinforcing Spacing
18 in.
Page 8
Design Intelligence, LLC JOHNSON SHOP 17J=2007
1037 Erikson Drive REXBURG. MADISON
Rexburg, Idaho 83440 COUNTY, IDAHO
Page 9