HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00391 - 398 Pioneer Rd - Rocky Ridge Apartments Bldg 5 - 4 PlexPermit
Inspection
Summary
Permit Status of (Issue) as of Report Date: 12/19/2018 10:04 am
Permit Details Permit Number: 17-00391
Rocky Ridge Apartments Bldg 5 - 4 Plex
398 Pioneer Rd
Multi-Family Residential
Permit Issued Date: 10/30/2017
Permit Inspection Statistics
34Total Inspections Completed:
27Total Inspections Passed:
Inspection Pass Rate: 79.41%
Permit Inspection History *Refer to Individual Inspection Report for more Details
10/04/2018PassQuinton OwensPlanning and Zoning Final Inspection
Planning & zoning final approval for the entire site will be tied to last building(s)
where bonus density points are required for the higher density.
Inspector Comments:
10/09/2018PassJoel GrayPublic Works Final Inspection
Building Inspection Type
07/18/2017PassTed DyeCommercial Footing Inspection
08/23/2017PassTed DyeCommercial Insulation Inspection
Interior foundation insulation inspectionInspector Comments:
11/20/2017PassTed DyeSheeting
Sheeting completed.Inspector Comments:
02/27/2018FailTed DyeCommercial Framing/Structure Inspection
03/14/2018PassQuinton OwensCommercial Framing/Structure Inspection
03/14/2018FailTed DyeCommercial Framing/Structure Inspection
03/15/2018PARTPASSQuinton OwensCommercial Sheetrock/Drywall Inspection
Attic fire partition rating inspection.Inspector Comments:
03/19/2018PassTed DyeFoundation Inspection
03/21/2018PassQuinton OwensCommercial Insulation Inspection
03/29/2018PassQuinton OwensCommercial Sheetrock/Drywall Inspection
Approved to tape (finish items noted above)Inspector Comments:
06/26/2018PassTed DyeSidewalk Inspection
06/26/2018FailTed DyeCommercial Building Final
5101 OK
5102 The Smoke detector in the living room is not communicating with the
others.
The Smoke detector in the living room is not communicating with the others.
5201 The Smoke detector in the living room is not communicating with the
others.
5202The Smoke detector in the living room is not communicating with the others.
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 17-00391
Rocky Ridge Apartments Bldg 5 - 4 Plex
398 Pioneer Rd
Multi-Family Residential
Permit Status of (Issue) as of Report Date: 12/19/2018 10:04 am
Permit
Inspection
Summary
12/12/2018PassTed DyeCommercial Building Final
Re-inspection of failed items.
Smoke detectors have been fixed to communicate with each other
Inspector Comments:
Electrical Inspection Type
02/14/2018PassBret StoddardCommercial Electrical Rough-in
02/14/2018PassBret StoddardCOM & MFR Electrical Service Inspection
06/26/2018PassBret StoddardResidential Electrical Final Inspection
Fire Inspection Type
04/18/2018PassDale PickeringFire Sprinkler Rough-in
04/18/2018PassDale PickeringFire Sprinkler Hydro
06/07/2018PassDale PickeringFire Sprinkler Hydro
06/25/2018PARTPASSDavid DavisFire Sprinkler Final Inspection
06/26/2018PassBret StoddardFire Alarm Final Inspection
Power shut-off 11AMInspector Comments:
06/28/2018PassDale PickeringFire Department Final Inspection
06/28/2018PassDavid DavisFire Sprinkler Final Inspection
Mechanical Inspection Type
03/13/2018PassDon AllenHVAC Rough-in
06/26/2018PassDon AllenHVAC Final Inspection
Plumbing Inspection Type
10/25/2017PassDon AllenPlumbing Sewer
Good to cover the sewer lineInspector Comments:
01/02/2018FailDon AllenPlumbing Rough-in
02/16/2018PassDon AllenPlumbing Rough-in
03/13/2018PassDon AllenPlumbing Rough-in
Good to cover the plumbing rough inInspector Comments:
04/11/2018PassDon AllenPlumbing Water
Good to cover the water lineInspector Comments:
06/07/2018PassDon AllenPlumbing Final Inspection
Page 2 of 2