Loading...
HomeMy WebLinkAboutTRUSS SPECS - 17-00379 - 2166 Summerfield Ln - New Kartchner SFR£Otl HE ai 30103 _ HE ai II. HE al HE 01 01 I , .yt ��_....�...HE HE on ...... H 01 — a al �__� __...�._.__.._..._._..:.. ... __.._..�.__.. .m L..... ` 8 01 _�.�,....,..._._.r... ..�.�.�.,.. szsnu a an ...._._,_....._._._..._. .. szsnu. a'a ... __.... .. _ ,.. szsnu. ads' .�....-.... O ..__. _,�.. 9ZSnN aal o Q - gzsnf I al ersn�{II szsn� i aad� ersni I 0 aOdV 9 _......_- szsn - Rk _ �.., aaoi I . 3 00 -00 -9I00 -00-w 00-00-7 scala = 762.4 5x6 = �.o — 5x8 = 5x8 = Plate Offsets (X Y) IB 0 8 0 0 061 IC 04 0 0-3-01 IG 04-0 0-3-01 IH 0-8-0 0 0 61 1804 0 0 3 Ol IK 04 0 0 3 Ol IL 0 4-0 0 3 01 ua LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/def! L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.47 Vert(LL) -0.30 K -L >999 360 MT20 220/195 TCDL 7.0 Lumber DOL 1.15 BC 0.57 Ven(TL) -0.50 K -L >871 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.29 Horz(TL) 0.16 H n/a We BCDL 7.0 Code IRC2012TPI2007 (Me Wind(LL) 0.11 K >999 240 Weight:1741b FT=20% LUMBER. BRACING - TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.t&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E BOT CHORD WEBS 2x4 OF Stud/Std'ExcepP WEBS W1,W2: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E REACTIONS. (Ib/size) B=1899/0-5-8 (min. 0-2-0), H=1899/0-5-8 (min. 0-2-0) Max Horz B=172(LC 12) Max UpliftB=-372(LC 8), H=-372(LC 9) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD B -C=-3373/625, C -D=-3008/575, D -E=-2115/441, E -F=.2115/441, F -G=-3008/576, G.H=-3373/625 BOT CHORD B.L=-637/2895, L -M=-428/2366, M -N=-028/2366, K -N=428/2366, K -O=-281/2366, O -P=-281/2366, J -P=.281/2366, HJ=465/2895 WEBS E -K=-243/1307, F -K=-854/331, F.J=.98/508, G.J=-444/231, D -K=-854/331, D.L=-97/508, C -L=-444/231 Sheathed or 3-1-11 oc purlins. Rigid ceiling directly applied or 84-1 no bracing I Row at midpt F -K, D -K MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation aulde. NOTES - 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vu11=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft between the bottom chord and any other members, with BCDL = 7.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (t=1b) B=372, H=372. 6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) "Semi-rigid pitchbreaks with fixed heels" Member and fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard ki1 Gable Scale = 1:62.8 AIM AG AF AEAD AC AS AA 2 YX 3x6 3x6 - 3x6 -- LOADING (psf) SPACING- 2-0-0 CSI. TCLL 35.0 Plate Grip DOL 1.15 TC 0.07 TCDL 7.0 Lumber DOL1.15 BC 0.02 BCU- 0.0 Rep Stress Ina YES WB 0.12 BCDL 7.0 Code IRC2012/TPI2007 (Matrix) LUMBER - TOP CHORD 20 DF 180OF 1.6E or 2x4 DF No.1&Btror 2x4 DF -N 180OF 1.6E BOT CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.i&Btr or 2x4 DF -N 180OF 1.6E OTHERS 2x4 DF Stud/Std 'Except' DEFL. in (100) Wall Ud PLATES GRIP VerfU-) -0.00 W n/r 120 MT20 220/195 Vert(TL) -0.00 W rdr 120 HOrz(TL) 0.01 V n/a n/a BRACING- TOPCHORD BOTCHORD WEBS ST9,ST8,ST7: 2x4 DF i800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 180OF 1.6E Weight: 220 lb FT = 20% Sheathed or 6-0-0 oc pudins. Rigid ceiling directly applied or 10-0-0 oc bracing. 1 Row at midpt L -AG, K -AH, M -AF MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer REACTIONS. All bearings 37.0-0. Installation guide (lb)- Max Horz B=172(LC 12) Max ft All lb less at Max Grraly All reactions 50rlb or less 0at Join (s) B, AG, H, AJ AK, AL, AM, AN, AO, APS, AF, AD, AC, A8, AA Z, Y, X, V FORCES. (lb) - Max, Comp./Max. Ten. • All forces 250 (lb) or less except when shown. TOP CHORD K -L=57/250 NOTES. 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7.10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf, h=256; Cat. II; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads In the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSVTPI 1. 4) All plates are 1.5x4 MT20 unless otherwise Indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at)oint(s) B, AH, AJ, AK, AL, AM AN, AO, AP, AF, AD, AC, AB, AA, Z, Y, X. V. 10) This truss is designed In accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) •Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard II i Scale =1:61.6 5X6 = 5X8 = 5z8 - 5x8 9-2-0 _ 18-6-0 27-8.12 36-9-0 9-2-0 9 9-2-4 i Plate Offsets (X.Y)- 1B:0-8-0 0-0.61 [C:044.0-3-01, fG•0-4-0 0-3-41 11'0-4.0 6-3-01 1J-.0-0-0 03-01 IK -.0-4-0 03-01 LOADING (pso SPACING- 2-0-0 CSI. DEFL. in (loc) Wall L!d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.54 Vert(LL) •0.30 J -K >999 360 MT20 220!195 TCDL 7.0 Lumber DOL 1.15 BC 0.60 Vert(TL) •0.52 J -K >848 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.29 Horz(TL) 0.16 H n/a n/a BCDL 7.0 Code IRC2012rTP12007 (Matrix) Wind(LL) 0.11 H•1 >999 240 I Weight: 172 lb FT=20% LUMBER" BRACING - TOP CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.l&Btr or 2x4 DF -N 1800F 1.6E TOP CHORD BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.l&Btr or 2x4 DF -N 1800F 1.6E BOT CHORD WEBS 2x4 OF Stud/Std'Excepr WEBS W2,W1,W3: 2x4 DF 1800F 1.6E or 2x4 DF NO.I&Btr or 2x4 DF -N 1800F 1.6E REACTIONS. (Ib/size) B=1897/0-5-8 (min. 0-2-0),H=1785/Mechanical Max Hoa B=181(LC 12) Max UpliftB=372(LC 8), H=.336(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD B.0=-33701624. C-0=30091577, D -E=.2110/441, E -F=-2108/441, F -G=-2981/575, G.H=.3322/622 BOT CHORD B -K 644/2892, K -L=437/2361, L -M=437/2361, J -M=437/2361, J -N=-287/2349, N-0=-287/2349,1-0=-287/2349, H-1=477/2864 WEBS C -K=-4421231, D -K=.99/513, D -J=-853/331, E -J=-244/1304, FJ=.847/329, F -I=-103/511, G-1=-441/232 Sheathed or 3-0.7 oc pudins. Rigid ceiling directly applied or 8-33 oc bracing 1 Row at midpt DJ, F -J MITek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. NOTES - 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7.10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live bad nonconcument with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members, with BCDL = 7.Opsf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 8=372, H=336. 7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANStlTPI 1. 8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard BMC WEBT (IgAHg Fa LU), 10MU FALLa, le 834Ux 5x6 = Scale=1:62.4 3x8 = 3x6 = AN AM AL AK AI AI AH AG AF AE AD ACAS AA Z Y X W V 3x6 = 3x6 = LOADING (psf, TCLL 35.0 TCDL 7.0 BCLL 0.0 BCDL 7.0 LUMBER - TOP CHORD BOTCHORD OTHERS SPACING- Nss Nss ype 1.15 y xARTCHNER SF3B11 HUNTINGTON 1.15 17-0T8001T A06 'Roof Spedal Sulxxxted Gade �ary 1 1 Job Reference(opeona0 _. J BMC WEBT (IgAHg Fa LU), 10MU FALLa, le 834Ux 5x6 = Scale=1:62.4 3x8 = 3x6 = AN AM AL AK AI AI AH AG AF AE AD ACAS AA Z Y X W V 3x6 = 3x6 = LOADING (psf, TCLL 35.0 TCDL 7.0 BCLL 0.0 BCDL 7.0 LUMBER - TOP CHORD BOTCHORD OTHERS SPACING- 2-0-0 Plate Grip DOL 1.15 Lumber DOL 1.15 Rep Stress Ina YES Code IRC2012/TP12007 36-9-0 36-9-0 CSI. DEFL in (loc) Well Wd TC 0.07 Vert(LL) -0.00 A n/r 120 BC 0.03 Vert(TL) 0.00 A n/r 120 WB OAS Horz(TL) 0.01 U n/a n/a (Matrix) BRACING - 2x4 DF 1800F 1.6E or 2x4 DF No.1 &Btr or 2x4 DF -N 1800F 1.6E TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E BOT CHORD 2x4 OF Stud/Std *Except* WEBS ST9,ST8,ST10,ST11: 2x4 OF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E PLATES GRIP MT20 220/195 Weight:218lb FT=20Y Sheathed or 6-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing 1 Row at micipt K -AE, J -AF, L -AD MiTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 36-9-0. (lb)- Max Horz B=t81(LC 12) Max Uplift All uplift 100 Ib or less at joint(s) B. AF, AH, Al, AJ, AK, AL, AM, AN, AD, AB, AA, Z. Y. X, W. V Max Grav All reactions 250 Ib or less st joints) B, AE, AF, AH, AI, AJ, AK, AL, AM, AN, AD, AB, AA, Z, Y, X, W, V. U FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES - 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psh BCDL=4.2psh h=25ft; Cat. Il; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise Indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) B, AF, AH, At, AJ, AK, AL, AM, AN, AD, AB, AA, Z. Y, X, W. V. 10) This truss is designed In accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSVTPI 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard fl Girder I1 9x12 MT18H 11 1i 4x1211 12x16 MT18H= 4x1211 8x12 MT20HSO LOADING (psf) SFACING. 2-0-0 Lid CSI. GRIP H-1 TCLL 35.0 TCDL 7.0 Plate Grip DOL 1.15 Lumber DOL MT20 TC 1.00 H -I DEFL. in Vert(LL) -0.23 BCLL 0.0 ' 1.15 Rep Stress Incr NO 165/146 BC 0.85 WB 0'81 n/a >999 Vert(TL) -0,37 SCOL 7.0 Code IRC2012/TPI2007 (Matrix) Horz(TL) -0.09 FT=20% Wind(LL) 0.12 LUMBER. TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr or 2x4 DF BOT CHORD 2x8 DF 1950F 1.7E or 2x8 OF SS -N 180OF 1.6E TOP CIHORD WEBS 2x4 OF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 'Except'BOT CHORD W2: 2x4 OF Stud/Std IBE WEDGE Left: 2x6 DF 1800F 1.6E or SS, Right: 2x6 OF 1800F 1.6E or SS REACTIONS. (Ib/size) F=10018/0-5-8 (min. 055), 8=9989/0-5-8 (min, 0-5-5) Max Harz F=203(LC 7) Max UpliftF=-1931(LC 9), B=-1907(LC 8) (loo) I/defi Lid PLATES GRIP H-1 >999 360 MT20 220/195 H -I >697 240 MT20HS I 165/146 B G -H n/a >999 n/a 240 MT16H 220/195 Weight: 273 lb FT=20% Sheathed. Rigid ceiling directly applied or 10-0-0 oc bracing FORCES. (Ib) - Max. Comp./Max. Ten. -AII forces 250 (Ib) or less except when shown. TOP CHORD B -C=-14336/2749, C-0--9747/1935, D -E=-9748/1934, E -F=-14394/2764 BOT CHORD BJ= -2166/11662, J -K=-2166/11662, 1-K=-2166/11662, I -L=-2166/11662, L -M=-2166/11662, M -N=-2166/11662, H -N=-2166/11662, H-0=-2299/11712, O -P--2299/11712, P -Q--2299/11712, G -Q=-2299/11712, G -R=-2299/11712, R -S=-2299/11712, F -S=-2299/11712 WEBS D -H=-1996/10217, E -H=-449911011, E -G=-906/4909, C -H- -4438/997, C -I=-891/4845 NOTES. 1) 2 -ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 -1 row at -0.4_0 ". Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-5-0 cc. Webs connected as follows: 2x4 - 1 row at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except it noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)-91mph; TCDL=4.OL=1.33 plate grip DOL=1.332psf; BCDL=4.2psf, h=25ft; Cat. 11; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber D 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=11b) F=1931, B=1907. 9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) Use Simpson Strong -Tie HUS26 (14-10d Girder, 4-10d Truss) or equivalent spaced at 2-0-0 cc max. starting at 2-0-12 from the left end to 20-0-12 to connect truss(es) A04 (1 ply 2x4 DF -N or DF) to back face of bottom chord. 12) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard Continued on page 2 Scala: 1/4"=1' 2 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase= 1.15, Plate Increase= 1.15 Uniform Loads Pin Vert: A -D=-84, D -F=-84,8-1`=-14 Concentrated Loads (Ib) Vert: B=-96 J=-1771(8) K=-1771(8) L=-1771(8) M=-1771(8) N=-1771(8) 0=-1771(8) P=-1771(8) Q=-1771(8) R= -1771(B) S=-1771(8) d� Scale =1:41.7 45 = 3x4= 5.6= """— 24-0-0 )o Plate Offsets (X Y)-- [H:0-3-0,0-3-01 LOADING (pat) SPACING- 2-0-0 CSI. DEFL. in floc) I/def! L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.43 Vert(LL) -0.12 1 >999 360 MT20 220/195 TCOL 7.0 Lumber DOL 1.15 BC 0.43 Vert(TL) -0.24 F -H >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.30 Hoa(TL) 0.07 F n/a n/a BCDL 7.0 Code IRC2012ITP12007 (Matrix) Wind(LL) 0.06 B-1 >999 240 Weight: 9616 FT=20% LUMBER - TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.i&Btr or 2x4 DF -N 1800F 1.6E WEBS 2x4 DF Stud/Std REACTIONS. (Ib/size) B=1263/0-3-8 (min. 0-1-8),F=1263/0-3-8 (min. 0-1-8) Max Ho¢ B=-96(LC 13) Max UpliftB=-255(LC 8), F=-255(LC 9) FORCES. (lb) - Max, Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD B -C=-2379/446, C -D=-2038/393, D -E=-2038/394, E -F=-2379/446 BOT CHORD B -1=435/2107.H -I= -180/1377,F -H=-339/2107 WEBS D -H=-156/676, E -H=.528/244, D.I=.156/676, C -I=-528/244 BRACING - TOP CHORD Sheathed or 3-11-14 oc puffins. BOT CHORD Rigid calling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing I installed during truss erection, In accordance with Stabilizer Installation guide, NOTES - 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. !I; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 01=115) B=255, F=255. 6) This truss is designed in accordance with the 2012 International Residential Code sections R502A 1.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7)'Semi-rigld pitchbreaks with fixed heels" Member end fixity model was used In the analysis and design of this truss. LOAD CASE(S) Standard _... -- �6--_ N33--�Twas YT -Pe - �Y -Ply TOP CHORD Sheathed or 6-0-0 oc purlins. KARTCHNER SF3a11 HUMINGTON - -- I1707880/T �CO3 IConvnon SuppwW Gable �1 1 LOADING (psf) l CSI. DEFL. In Job Reference (optional) Scale=1:41.7 4x5 = 3x4 - V U T 5 R O P O N 3x4 = 5x8 =' Plate Offsets (X.YI- [P;0-3-0,0-3-01 TOP CHORD 20 OF 1800F 1.6E or 2x4 OF No.1&Bb or 2x4 DF -N 1800F 1.6E TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Bir or 2x4 DF -N 180OF 1.6E BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. OTHERS 2x4 OF Stud/Std--- MiTek recommends that Stabilizers end required cross bracing LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) gdefi Lld PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.13 Vert(LL) 0.00 M nlr 120 MT20 220/195 TCDL 7.0 Lumber DOL 1.15 BC 0.06 Vert(TL) 0.01 M n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(TL) 0.00 L n/a n1a BCDL -ZO_- Code IRC20121TP12007 (Matrix) Weight: 107 Ib FT=20% LUMBER- BRACING - TOP CHORD 20 OF 1800F 1.6E or 2x4 OF No.1&Bb or 2x4 DF -N 1800F 1.6E TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Bir or 2x4 DF -N 180OF 1.6E BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. OTHERS 2x4 OF Stud/Std--- MiTek recommends that Stabilizers end required cross bracing be Installed during truss erection, In accordance with Stabilizer Installation guide. REACTIONS. All bearings 24-0-0. _ ----- (Ib) - Max Horz B=-96(LC 9) Max Uplift All uplift 100 Ib or less at joint(s) B, S, T, U, 0, P. O, L except V=A 18(LC 8), N=-118(LC 9) Max Grav All reactions 250 lb or less at joint(s) R, S, T, U. 0, P. O except B=269(LC 1), V=375(LC 19), N=375(LC 20), L=269(LC 1) FORCES. (lb) -Max. Camp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS C -V=.299/137, K -N=-299/136 NOTES - 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7.10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psh, BCDL-4.2psF h=25ft; Cat. II; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads In the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-M oc. 7) This truss has been designed for a 10.0 psf bottom chord live load noncencument with any other live loads. 8)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B. S. T. U, 0, P. O, L except Qt=1b) V=118, N=118. 10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) B. 11) This truss Is designed In accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard I Common 4x5 = 4x8 II 1.5x4 II 4x8 II M Scale =1:25.9 Plate Offsets(X,Y)-- 16:0-3-8.Edgel. 10:0-3$Edoel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loo) I/dell L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.34 Ven(LL) -0.03 B -F >999 360 MT20 220/195 TCDL 7.0 Lumber DOL 1.15 BC 0.21 Vert(TL) -0.06 B -F >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(TL) 0.01 D n/a n/a BCDL 7.0 Code IRC2012/rP12007 (Matrix) Wind(LL) 0.03 B -F >999 240 Weight: 4416 FT=20% LUMBER - TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.l&Btr or 2x4 DF -N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E WEBS 2x4 DF Stud/Std WEDGE Left: 2x4 OF Stud/Std, Right: 2x4 OF Stud/Std REACTIONS. (Ib/size) 8=643/0-5-8 (min. 0-1-8), 0=643/0-5-8 (min. 0-1-8) Max Horz B=-117(LC 6) Max UpliftB=-130(LC 8), D=-130(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD B -C=-636/119, C -D=-636/119 BOT CHORD B -F=-30/402, D -F=-30/402 BRACING - TOP CHORD Sheathed or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES - 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except Qt=1b) 8=130, D=130. 6) This truss Is designed In accordance with the 2012 International Residential Cade sections R502.11.1 and R802.10.2 and referenced standard ANSI1TPI 1. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard 002 Ceimnn euppaxed Gable 4x5 = 3x8 I I " 3x4 3x8 11 LOADING (ps,SPACING- 2.0-0 TCLL 35.0 Plate Grp DOL 1.15 TCDL 7.0 Lumber DOL 1.15 BCLL 0.0 Rep Stress Incr YES BCDL 7.0 Code IRC2012rfP12007 CSI.DEFL. In (loo) gdefl Ud TC 0.07 Vert(LL) -0.00 1 n/r 120 BC 0.03 Vert(TL) -0.00 1 nir 120 WB 0.04 HOrz(TL) 0.00 H n/a n1a (Matrix) LUMBER- - — TOP CHORD 2x4 DF 1800E 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E BOT CHORD 2x4 DF 180OF 1.6E or 2x4 OF No.1 &Btr or 2x4 DF -N 180OF 1.6E OTHERS 2x4 DF Stud/Std WEDGE Left: 2x4 DF Stud/Std, Right: 2x4 OF Stud/Std REACTIONS. All bearings 11-4.0. (lb)- Max Hom B=-117(LC 6) Max Uplift All uplift 100 Ib or less at Joint(s) B, H. M, N. K. J Max Gmv All reactions 250 Ib or less at Joint(s) B, H, L. M, N. K, J FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Scale =127.5 [3 PLATES GRIP MT20 220/195 Weight: 53 lb FT=20% BRACING- - -- - TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabitizere and required cross bracing be Installed during truss erection In accordance with Stabilizer .,installation guide_ NOTES - 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7.10; Vui1=115mph (35econd gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed : Lumber DOL=1,33 plate grip DOL=1.33 3) Truss designed for wind loads In the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 1.5x4 MT20 unless otherwise Indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 8) • This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at Joints) B, H. M, N, K, J. 10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 standard ANSIend referenced 1. 11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used In the analysis and design of this truss. LOAD CASE(S) Standard 4x511 Scale =1:15.6 C j 2x4 - 1.5x4 I; Plate Offsets (X Y) - L=-2-8,0-1-121 LOADING (Pat) SPACING- 2.0-0 CSI. I DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.51 Vert(LL) -0.05 B -D >999 360 MT20 220/195 TCDL 7.0 Lumber DOL 1.15 BC 0.21 Vert(TL) -0.10 11-D >841 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C Na n/a BCDL 7.0 Code IRC2012rrP12007 (Matrix) Wlnd(LL) 0.00 B •••• 240 Weight: 21 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 OF 1800F 1.6E or 2x4 DF NoA&Bb or 2x4 DF -N 1800E 1.6E TOP CHORD BOT CHORD 2x4 DF 1800E 1.6E or 2x4 DF No.i&B(r or 2x4 DF -N 1800F 1.6E BOT CHORD WEBS 2x4 DF Stud/Sid REACTIONS. (lb/size) C=224/Mechanical, D=39/Mechanlcel, B=385/0-3-8 (min. 0.1-8) Max Horz B=103(LC 4) Max UpliftC--104(LC 8), 8=-102(LC 4) Max GmvC=224(LC 1), D=95(LC 3), 8=385(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown Sheathed or 5-10.8 oc pudins, except end verticals. Rigid ceiling directly applied or 10.0-0 oc bracing. 11 MTek recomrnerids that §iabllizers end required cross bracing be installed during truss erection, In accordance with Stabilizer Installation guide. _..... _—_--.__._. NOTES - 1) Wind: ASCE 7-10; Vult-115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (envelope) gable and zone; cantilever left and right exposed: Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) C=104, B=102. 6) This truss Is designed In accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSVTPI 1. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Gap between Inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Truss Truss Type 17-078604T Em GE Mompitch Structural Gable 7 fiMCWifsf IDAHOFALLSj, 1bmo FALLS, IGa3402 __- 4x5 11 2x4 = 1.5x4 II Id Scale= 1:15.6 Plate Offsets (X.Y)- rC:0-2-8.0-1-121 LOADING (psf) SPACING- 2-0-0 CSI. 1 DEFL, in (loc) Vde6 Ud PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.51 Vert(LL) -0.05 B -D >999 360 MT20 220/195 TCDL 7.0 Lumber DOL 1.15 SC 0.21 Vert(TL) -0.10 B -D >641 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C n/a n/a BCDL 7.0 Code IRC20127rP12007 (Matrix) Wind(LL) 0.00 B "'" 240 Weight: 21 lb FT=20% LUMBER- BRACING• TOP CHORD 2x4 DF 1800F 1.8E or 2x4 DF No.t&Btror 2x4 DF -N 1800F 1.6E TOP CHORD BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Blror 2x4 OF -N 1800F 1.6E BOT CHORD WEBS 2x4 OF Stud/Std REACTIONS. (Ib/size) C=224/1VIechanical, D=39/Mechanical, B=385/0-3-8 (min. 0.1-8) Max Horz 8=103(LC 4) Max Upl1ftC=-104(LC 8), B=-102(LC 4) Max Grav C=224(LC 1), D=95(LC 3), B=385(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. Sheathed or 610-8 oc purlins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing j be Installed during truss erection, In accordance with Stabilizer J Installation guide. _ NOTES - 1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCOL=4.2psf; BCDL-4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will Bt between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) C=104, B=102. 6) This truss is designed In accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSVTPI 1. 7) "Semi-rigid pltchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Gap between Inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Scale =1:15.4 2X4 = 1.5x4 ll LUMBER - TOP CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.1 &Bir or 2x4 DF -N 1800F 1.6E BOT CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.1 &Bb or 2x4 DF -N 1800F 1.6E WEBS 2x4 OF Stud/Std REACTIONS. (Ib/size) E=469/Mechanical, B=161/0.3.8 (min. 0.1 -8) Max Horz B=100(LC 4) Max UpliftE=-180(LC 5), B=-36(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD C -E=448/193 BRACING - TOP CHORD Sheathed or 3-3-12 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. rMiTek recommends that Stabilizers and required cross bracing 1. be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES - 1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. ll; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will Bl between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B except (jt=1b) E=180. 6) This truss is designed In accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used In the analysis and design of this truss. LOAD CASE(S) Standard 3-12 LOADING (psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deb L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.49 Vert(LL) -0.00 B-E >999 360 MT20 220/195 TCDL 7.0 Lumber DOL 1.15 BC 0.05 Vert(TL) -0.01 B-E >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Hoa(TL) 0.00 n/a n/a I BCDL 7.0 Code IRC2012/TPI2007 (Matrix) Wind(LL) 0.00 B "" 240 1 Weight: 16 lb FT=20% LUMBER - TOP CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.1 &Bir or 2x4 DF -N 1800F 1.6E BOT CHORD 2x4 OF 1800F 1.6E or 2x4 DF No.1 &Bb or 2x4 DF -N 1800F 1.6E WEBS 2x4 OF Stud/Std REACTIONS. (Ib/size) E=469/Mechanical, B=161/0.3.8 (min. 0.1 -8) Max Horz B=100(LC 4) Max UpliftE=-180(LC 5), B=-36(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD C -E=448/193 BRACING - TOP CHORD Sheathed or 3-3-12 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. rMiTek recommends that Stabilizers and required cross bracing 1. be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES - 1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. ll; Exp C; enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will Bl between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B except (jt=1b) E=180. 6) This truss is designed In accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used In the analysis and design of this truss. LOAD CASE(S) Standard umc rvca r lrvwru Howl. ruwty rvuw, ru aM'&1152015 mrak Inxweaes, era Thu J010510:14:262017 Page ID:QP1efQbbwf0E0dtuuhk4ibzl NpBe9gBk CQLGnb 619EFCE iFU1OYzhJQB DIM_Wz .R Scale =1:10.5 2x4 - 1.5x4 11 LOADING (psf) mss yT — DEFL. In (lac) y KARTCHNER SF3611 HUNOTON NTI 17A785U1T E03 Morroplttlr $ t B-E >999 380 TCDL 7.0 Lumber DOL 1.15 BC 0.05 Job Reference (optional) umc rvca r lrvwru Howl. ruwty rvuw, ru aM'&1152015 mrak Inxweaes, era Thu J010510:14:262017 Page ID:QP1efQbbwf0E0dtuuhk4ibzl NpBe9gBk CQLGnb 619EFCE iFU1OYzhJQB DIM_Wz .R Scale =1:10.5 2x4 - 1.5x4 11 LOADING (psf) SPACING• 2-0-0 CSI. DEFL. In (lac) I/deg L/d TCLL 35.0 Plale Grip DOL 1.15 TC 0.10 Vert(LL) -0.00 B-E >999 380 TCDL 7.0 Lumber DOL 1.15 BC 0.05 Vert(TL) -0.01 B-E >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Hoa(TL) 0.00 n/a n/a BCDL 7.0 Code IRC20121TPI2007 (Matrix) Wind(LL) 0.00 B ' " 240 LUMBER - TOP CHORD 2x4 DF 1800F 1.6E or 2x4 OF No.1&Bir or 2x4 DF -N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 OF No.1&Bir or 2x4 DF -N 1800F 1.6E WEBS 2x4 DF Stud/Std REACTIONS. (Ib/size) E=131/Mechanical, B=268/0-3-8 (min. 0-1-8) Max Hoa B=68(LC 4) Max UpliftE=48(LC 8), B=-85(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. PLATES GRIP MT20 220/195 Weight: 12 lb FT=20% BRACING - TOP CHORD Sheathed or 3-3-12 oc puriins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. rMffek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installation guide. NOTES - 1) Wind: ASCE 7.10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psh BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MW FRS (envelope) gable end zone; cantilever left and right exposed ; Lumber DOL -1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100111 uplift at)olnt(s) E, B. 6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASES) Standard 17-0786047 IE04 1 MonopltM SUppaktl Gable 33 3412 I 24 2X4 = 1.5x4 II LOADING (psf) SPACING- 2-0-0 CSI. DEFL. In (loc) I/deg Ud TCLL 35.0 Plate Grip DOL 1.15 TC 0.49 Vert(LL) 0.06 D n/r 120 TCDL 7.0 Lumber DOL 1.15 BC 0.06 Vert(TL) -0.02 D n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 7.0 Code IRC20121TPI2007 (Matrix) I LUMBER - TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.i&Btr or 2x4 DF -N 1800F 1.6E BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF -N 1800F 1.6E WEBS 2x4 DF Stud/Std REACTIONS. (Ib/size) E=477/3-3-12 (min. 0.1.8), B=155/3-3-12 (min. 0-1-8) Max Horz B=100(LC 4) Max UptiftE=-179(LC 5), B=-32(LC 4) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD C -E=455/192 Scale= 1: 16.4 PLATES GRIP MT20 220/195 Weight: 16 lb FT=20% BRACING - TOP CHORD Sheathed or 3-3.12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. MITek recomat Sta mends thbilizers and required cross bracing l be Installed during truss erection, In accordance with Stabilizer Installation guide. NOTES - 1) Wind: ASCE 7-10; Vult=115mph (3 -second gust) V(IRC2012)=91 mph; TCDL=4.2psh BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MWFRS (envelope) gable and zone; cantilever leg and right exposed ; Lumber DOL -1.33 plate grip DOL -1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load noncencument with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B except Qt=lb) E=179. 8) This truss is designed In accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPl 1. 9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used In the analysis and design of this truss. LOAD CASE(S) Standard