HomeMy WebLinkAboutRESCHECK - 17-00294 & 17-00295 - 889 & 890 Parkside Dr - New SFRCREScheck Software Version 4.6.2 �(J Compliance Certificate Project West Unit Energy Code: 2012 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 2,091 ft2 Glazing Area 8% Climate Zone: 6 (8693 HDD) Permit Date: 20 Permit Number: Construction Site: Rexburg, ID 83440 Owner/Agent: Habitat for Humanity Idaho Falls, ID Designer/Contractor: Compliance: Passes using LIA trade-off Compliance: 0.7% Better Than Code Maximum UA: 776 Your UA: 274 The % Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade -of rules, It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Ceiling 1: Flat Ceiling or scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Vinyl/Fiberglass Frame:Double Pane with Low -E Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Vinyl/Fiberglass Frame:Double Pane with Low -E Wall 3: Wood Frame, 16" o.c. Window 3: Vinyl/Fiberglass Frame:Double Pane with Low -E Door 2: Glass Wall 4: Wood Frame, 16" o.c. Door 3: Solid Floor 1: All -Wood Joist/rruss:Over Unconditioned Space Crawl 1: Solid Concrete or Masonry Wall height: 4.0' Depth below grade: 3.5' Insulation depth: 3.0' P C�_'f 1,287 0.0 50.0 0.019 24 751 21.0 0.0 0.057 38 71 0.250 18 20 0.500 10 587 21.0 0.0 0.057 31 45 0.250 11 746 21.0 0.0 0.057 37 57 0.250 14 40 0.250 10 587 21.0 0.0 0.057 32 20 0.250 5 804 38.0 0.0 0.026 21 481 0.0 10.0 0.077 23 Project Title: West Unit Report date: 05/30/17 Data filename: C:\Users\rmalm.JRWA\Desktop\Habitat\5-30-2017\west.rck Page 1 of 2 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Date Project Title: East Unit Report date: 05/30/17 Data filename: C:\Users\rmalm.jRWA\Desktop\Habitat\5-30-2017\east.rck Page 2 of 2 CREScheck Software Version 4.6.2 �(J Compliance Certificate Project East Unit Energy Code: 2012 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1,692 ft2 Glazing Area 10% Climate Zone: 6 (8693 HDD) Permit Date: 20 Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Rexburg, ID 83440 Habitat for Humanity Idaho Falls, ID Compliance: Passes using UA trade-off Compliance: 1.2% Better Than Code Maximum UA: 249 Your UA: 246 The %Better or Worse Than Code Index reflects how close to compliance the house is based on code tradeoff rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Vinyl/Fiberglass Frame:Double Pane with Low -E Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Vinyl/Fiberglass Frame:Double Pane with Low -E Wall 3: Wood Frame, 16" o.c. Window 3: Vinyl/Fiberglass Frame:Double Pane with Low -E Door 2: Glass Wall 4: Wood Frame, 16" o.c. Door 3: Solid Floor 1: All -Wood Joist/rruss:Over Unconditioned Space Crawl 1: Solid Concrete or Masonry Wall height: 4.0' Depth below grade: 3.5' Insulation depth: 3.0' Project Title: East Unit Data filename: C:\Users\rmalm.JRWA\Desktop\Habitat\5-30-2017\east.rck t�a6t 894 0.0 50.0 0.019 17 656 21.0 0.0 0.057 30 106 0.250 27 20 0.500 10 466 21.0 0.0 0.057 25 20 0.250 5 656 21.0 0.0 0.057 32 49 0.250 12 40 0.250 10 466 21.0 0.0 0.057 25 20 0.250 5 894 38.0 0.0 0.026 23 518 0.0 10.0 0.077 25 Report date: 05/30/17 Page 1 of 2 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirercentsiisted,in the REScheck Inspection Checklist. -5-- "w -.Zbr4 re Project Title: West Unit Report date: 05/30/17 Data filename: C:\Users\rmalm.JRWA\Desktop\Habitat\5-30-2017\west.rck Page 2 of 2