Loading...
HomeMy WebLinkAboutCHECKLIST - 17-00262 - 272 Mark Ave - SFR AdditionRESIDENTIAL PLAN CHECKLIST (2012 International Residential Code) Date: (Q- l! w 11 Building Permit Number: -17 —J Project: sf, k. Job Address: Q" -fa MaA Ave Zoning: 44�" Number of Stories: �_ Basement: Yes No / Fin. Unfin. (Note unfinished basements as special condition on permit) Floor Area (sf): finished, unfinished, garage. The following comments based on the 2012 edition of the International Residential Code should be resolved before a building permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International Residential Code or any federal, state, or local regulations. PLAN CHECK A. Plans To Scale Legible Plot Plan Y/N Flood Plain Floor/Foundation Plan _Section showing construction details _All Building Elevations Design Criteria (shall be identified on plans as Wind — 85 m.p.h., Snow — 35 lb. Per sq ft.) Truss Calculation Sheets & Floor Joist Details _Mechanical Design Energy Calculations (R320 & Ch 11) B. Zoning (circle one — new zoning designations adopted in 2005) LDRI 12,000 sf min. (width 80 ft. min) LLDR 8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P. RR2 21,780 sf min. (width 150 ft. min) Duplex allowed with C.U.P. Other (Verify zoning requirements) C. Use _Single Family _Duplex (LDRI only — Conditional use permit?) D. Set Backs (taken from eaves) Front set back (32 ft. from curb) _Note: 60% min of front yard green Rear set back (LDRI 25 ft. _Sides set back (6" for every ft. of building height with LDR — 7.5' min., & LDR1— 6' min.) _Building -Height (maximum 30 ft.) E. Footings _Proper Size (as per Table 403.1, use 1500 psf unless soil type is known, Table 401.4.1 for soil bearing) Rebar (244 continuous) _Building -Height (maximum 30 ft.) F. Foundation Foundation walls w/ rebar (city ordinance) 1/2" Anchor Bolts R403.1.6 with 3" x 3" x 1/4" square washers R602.11.1 (incl. interior bearing walls) Foundation Drainage (foundations on sift soil shall be designed per R405) Damp proofing/ Waterproofing to finish grade. R406.1 (fid. Extends 6" min above grade R404.1.6) Crawl space access of 18" x 24" min. R408.4 (may differ if mech appliance is in crawl space M1305.1.4 Crawl space ventilation/insulation = 1 sf. vent per 150 sf. (with moisture barrier 1 sf. Per 1500 sq. ft.) and within 3' of each corner (insulate walls vent to inside of home) R408.2 G. Frame Seismic Hold Downs and Braced Wall Panels (R602.10) _Floors joists sized as per R502.3, Wood 1 -joists sized per manufr. Joists Under Load Bearing Partitions shall be doubled. R502.4 Girders sized per R502.5 or per manufr. Tables for engineered products Cantilevers (comply with R502.3.3 or manufr instruction) Floor Sheathing (3/4" min for joists 24" oe & 5/8" for joists 16" oc) R503.2.2 _Wall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R602.3 _Headers in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7 _Stair Rise/ Run (7 3/4" max. rise & 10" min. tread, nosing req'd if <11") _Stair Width (36" min), _Stairway Headroom (6'8" min.) _Handrails (34" to 38" above stair nosing) (11311.5) _Special conditions for circular, spiral and winder stairways and bulkhead enclosures R311.5.8 _Stairway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R302.7 Guardrails complying with R312 Smoke Alarms (each bedroom and common area and one on each level) (R314) L. Energy _Homes with glazing < 15% of gross area of ext. was (Townhouses < 25%) to comply w/ Chapter 11. *Otherwise shall meet requirements of IEXX for respective building type. N1101.2 Vapor retarder on warm in winter side of walls, ceiling and floors R702.7 Duct sealing and insulation N1103.2 or IECC 403.2.2, 403.2.2.1 Plans match quantities & values on a "passing" REScheck compliance report M. Mechanical _Gas appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G2406.2 Room access 24" min width/Attic access clear opening 22" x 30"/Under floor r.o. 22xx30. M1305 _Dryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1502.4.4 _Flue chase shown on plans (13 -vents not to be inside insulated walls without insulation shield) _Radon _Roof Trusses (designed according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) _Rafter and Truss tie -downs. (R08.11) Attic Access 22" x 30" min. opening (R807) H. Exterior Covering _Masonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.2.1 I. Roof Covering and Ventilation _Roof Ventilation as per R806 _Asphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905.� J. Firewalls Garage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2 Door from Garage to House (1 3/8" solid wood or steel door, or 20 min. fire -rated door self-closing device) R302.5.1 _Two Family Dwelling Separation (1 hr fire separation) Supporting structure also rated. R302.3 _Twin homes & Townhouses (2 hr separation & 4' overburn protection or parapet) R302.2 _One hr walls parallel to and within 3 ft of property line w/ NO openings. R302 _Penetrations in previous 3 items to comply with R302.4 K. General Requirements _House Numbers R319.1 _Half Openable 3sf window or Mech. Ventilation in bathrooms, water closets, and similar rooms. R303.3 _Interior and exterior stair illumination shall comply with R303.4 _Bathroom Fixture clearances comply with R304.1 One room at least 120 s£; _Other habitable rooms 70 s£ Min w/ a min. dimension of 7 ft. R304 *areas w/ sloped ceilings less than 5 ft in height & furred ceilings less than 7 ft DO NOT comply *50% or more of the required area must be at least 7ft high in rooms w/sloped ceiling Egress clearance from window wells under cantilevered floors. R310.2 _Glazing at Hazardous Locations R308 _Emergency Egress in all sleeping rooms and basements with habitable space R310 One required Exit Door shall comply with R311.2 _Landings at top and bottom of stairways R311.7.6, and each side of each exterior door. R311.3