HomeMy WebLinkAboutFIRE ALARM REPORT - 18-00527 - 430 W 2nd S - Providence Square - ClubhouseM -F'INE NMBE ALARMS ' FIRE ALARM INSPECTION AND TESTING REPORT Testing performed in accordance with applicable NFPA 72 Standards / By NICET Certified Technicians Building occupied as0, ; � g � � �s e 1 I , s S � � � Address of Buildin r Owner /Manager: Name & Number r 2 i7 Name of Tester r{�s•. r a . - , Date of Inspection Type of Inspection Notification of Testing s, s. Control Panel Manufacturer & Model,,�,....�,.. # of Zones: SLC Loopes: t! NAC's - FACP: FCPS: Total NAC's 4-1System should be tested on Standby (battery power) for 30 min. prior to Battery Test. Rattery Insnectinn Battery Voltage FACP FCPS1 FCPS2 FCPS3 Voltage Z Amp Hour Date on Battery �42 FACP Inspection YES NO N/A # of Units Satisfactory: Satisfactory: N/A Tested Yes No YES NO N/A Key to Panel Available All circuits checked for electrical supervision Elev. Recall Shunt Dialer, Communicator. Operating Instructions at Panel Newest Record posted at Panel All functions and buttons work properly t! g .4.7 Door Holders Smoke Detectors circuit Breaker marked Red circuit Breaker Panel:, , • # A Does Alarm system meet audibility standards % Duct Detectors Trouble Signal with AC Power off System operates satisfactory on standby power at max load Control Panel checks made per manufacturer's instruction f' Flow Switches All signals oerate on AC power All interfaced equipment operates Elevators, Fans, Dampers) Tamper Switches All LED's Illuminate t Name of Monitoring Company: �, ,� (, , /� ; , Account Communication Verified: L ; 4 1 -- Equipment Tested Type of Equipment # of Units Satisfactory: Satisfactory: N/A Tested Yes No # of Units in Bldg. FCPS Power Booster Elev. Recall Primary Annucitors Elev. Recall Shunt Dialer, Communicator. Access Control Door Release (Failsafe) Horns, Strobes, Bells, Chimes, Speakers, Etc. t! g .4.7 Door Holders Smoke Detectors Heat Detectors % Duct Detectors ►{ Pull Stations f' Flow Switches Tamper Switches Low/High Air Switches Antifreeze Tamper Ansul System Problems Found: N/. Interfaced Equipment # of Units Satisfactory: Satisfactory: N/A # of Units Tested Yes No in Bldg. Ventilation Controls x Elev. Recall Primary Elev. Recall Sec Elev. Recall Shunt ,- Access Control Door Release (Failsafe) Auto Release X Door Holders Corrections Made: This is to certify that this Fire Alarm has been properly Tested and Inspected for liability to cover the items listed in this report, according to Manufacturers Recommendation. Signature of Fire Marshall:_ Date: y _ Signature of Owner or representative: `� Date: Signature of Certified TestDate:_ 4{ ,