Loading...
HomeMy WebLinkAboutINSPECTION TICKETS - 17-00662 - 902 Oak Hill Way - New SFRInspection Ticket Residential Electrical Final Inspection on 08/17/2018: PASS Permit Number: 17-00662Permit Details Building - Single Family Residence Permit Issued Date: 11/27/2017 Final Inspections Required HVAC Final Inspection Plumbing Final Inspection Residential Electrical Final Inspection Residential Building Final Plumbing Final Inspection HVAC Final Inspection Residential Building Final 902 Oak Hill Way 902 Oak Hill Way - New SFR Inspection Details bret.stoddard@rexburg.org Inspected By: Bret Stoddard Residential Electrical Final Inspection on 08/17/2018: PASS D ESCRIPTIO N CO M M EN TS STATUS Check for correction of any deficiencies noted on previous inspections. COMPLETED Positioning of boxes intended to be flush with combustible and noncombustible finished surfaces. 314.20 COMPLETED Gaps around boxes in walls. 314.21 COMPLETED Polarity of devices and luminaires. 200.10(B), 200.11, 410.23, 406.9 COMPLETED Proper use of connectors and fittings and for protection of cables. 300.15 COMPLETED Unused openings in boxes and other enclosures are closed. 110.12, 314.17(A), 312.5(A) COMPLETED Bushings or equivalent protection for cables entering boxes and other enclosures. 300.4(F), 314.17, 314.42 COMPLETED Installation of listed equipment for compliance with manufacturer’s instructions. 110.3(B) COMPLETED Disconnecting means on both permanently connected and cord- and plug-connected appliances. Article 422 Part III COMPLETED Circuits for mechanical equipment have correct conductor size and overcurrent protection. Articles 422, 424, 430, and 440 COMPLETED Spacing of receptacles for walls and countertops, including islands and peninsulas. 210.52(A) and (C) COMPLETED Countertop receptacles are provided with GFCI protection. 210.8(A)(6) COMPLETED Properly sized circuits are provided for specific kitchen appliances, such as dishwashers, disposals, ranges, cooktops, trash compactors, and the like. 210.23, 422.10 COMPLETED Page 1 of 2 (Continued) Permit Number: 17-00662 D ESCRIPTIO N CO MMEN TS STATUS Bathroom receptacles are GFCI protected. 210.8(A)(1) COMPLETED Arc-fault circuit-interrupter (AFCI) protection on bedroom circuits. 210.12 COMPLETED Clearances between luminaires and storage spaces if luminaires are installed. 410.8 COMPLETED Proper receptacle ratings based on branch-circuit ratings, including receptacles for electric dryers. 210.21, 210.24, 250.140 COMPLETED GFCI protection at laundry sink locations within 6’. 210.8(A)(7) COMPLETED At least one receptacle outlet is provided in unfinished basement areas in addition to any receptacles installed for laundry equipment and is GFCI protected. 210.52(G), 210.8(A)(5) COMPLETED Receptacle outlet is provided for servicing mechanical equipment. 210.63 COMPLETED Wall-switch-controlled lighting outlet or a lighting outlet containing a switch is provided at the entrance to equipment requiring servicing. 210.70(A)(3) COMPLETED Outdoor receptacles are GFCI protected unless they are not readily accessible and are supplied by circuits for deicing or snow-melting equipment(GFPE required otherwise with a disconnecting means-breaker lock). 210.8(A)(3), 426.28, 426.50(A) COMPLETED Proper identification of all overcurrent devices and disconnects. 110.22, 230.70(B), 408.4 COMPLETED Open spaces in panelboard fronts. 110.12 COMPLETED Approved for a Final and C.O.For a final and C.O.-items corrected from prior inspection, finished basement entirely, A/C unit installed. Two receptacles not installed on both sides of the fireplace in the kitchen/dining area, please call for a re-inspect when done. COMPLETED Page 2 of 2 Inspection Ticket Plumbing Final Inspection on 08/17/2018: FAIL Permit Number: 17-00662Permit Details Building - Single Family Residence Permit Issued Date: 11/27/2017 Final Inspections Required HVAC Final Inspection Plumbing Final Inspection Residential Electrical Final Inspection Residential Building Final Plumbing Final Inspection HVAC Final Inspection Residential Building Final 902 Oak Hill Way 902 Oak Hill Way - New SFR Inspection Details don.allen@rexburg.org Inspected By: Don Allen Plumbing Final Inspection on 08/17/2018: FAIL D ESCRIPTIO N CO M M EN TS STATUS Approved for a Final and C.O.Need access panel for the jetted tub installed FAIL Inspection Ticket HVAC Final Inspection on 08/17/2018: FAIL Permit Number: 17-00662Permit Details Building - Single Family Residence Permit Issued Date: 11/27/2017 Final Inspections Required HVAC Final Inspection Plumbing Final Inspection Residential Electrical Final Inspection Residential Building Final Plumbing Final Inspection HVAC Final Inspection Residential Building Final 902 Oak Hill Way 902 Oak Hill Way - New SFR Inspection Details don.allen@rexburg.org Inspected By: Don Allen HVAC Final Inspection on 08/17/2018: FAIL D ESCRIPTIO N CO M M EN TS STATUS Approved for a Final and C.O.Need to know what the vent behind the fireplace is for. Need to check with building code for having access to the fireplace in the garage. FAIL Inspection Ticket Residential Building Final on 08/17/2018: FAIL Permit Number: 17-00662Permit Details Building - Single Family Residence Permit Issued Date: 11/27/2017 Final Inspections Required HVAC Final Inspection Plumbing Final Inspection Residential Electrical Final Inspection Residential Building Final Plumbing Final Inspection HVAC Final Inspection Residential Building Final 902 Oak Hill Way 902 Oak Hill Way - New SFR Inspection Details larry.beesley@rexburg.org Inspected By: Larry Beesley Residential Building Final on 08/17/2018: FAIL D ESCRIPTIO N CO M M EN TS STATUS Insulation Certificate provided?NO Approved for a Final in noted levels.N/A Are As-Built Plans required?N/A Check for house number FAIL Exterior egress components (driveways, sidewalks, ramps, etc.) completed FAIL Landscaping and other exterior construction activities completed or properly separated Grading around the concrete will need to be completed when the concrete is all completed. Also drain and grading by basement walkout door in the back. FAIL mechanical, electrical, plumbing and P&Z finals are completed FAIL Approved for a Final and C.O.FAIL All egress components (ramps, landings, stairs, handrails, guardrails, etc.) meet code COMPLETED Doors are correct size, swing, and rating COMPLETED Safety glazing is provided in required locations COMPLETED Foam insulation is covered as per code COMPLETED Exterior Stucco or EIFS installed as per code COMPLETED All building construction is complete COMPLETED Adequate slope and drainage from foundation (including drainage tiles, basins, vaults, etc.) COMPLETED Page 1 of 2 (Continued) Permit Number: 17-00662 D ESCRIPTIO N CO MMEN TS STATUS Smoke detectors working properly and in right locations COMPLETED Smoke & C.O detector outside bedrooms COMPLETED Ladders in window wells (one in basement or one in each bedroom window well) COMPLETED Gas water heater have two straps: top & bottom COMPLETED Exterior landings, risers, & treads are proper size COMPLETED Garage step risers & treads are correct COMPLETED Handrails for landings & steps COMPLETED Inspector Comments The access in the garage behind the fire place is is not allowed unless it has a 26 Gage metal access door or panel covering the opening and sealed. The concrete driveway and sidewalks all need to be completed before occupancy is permitted. Adjust the self closing hinges on the garage door. Make all corrections and call for re inspections. Thanks, Larry Page 2 of 2