HomeMy WebLinkAboutINSPECTION TICKETS - 17-00662 - 902 Oak Hill Way - New SFRInspection
Ticket
Residential Electrical Final Inspection on 08/17/2018: PASS
Permit Number: 17-00662Permit Details
Building - Single Family Residence
Permit Issued Date: 11/27/2017
Final Inspections Required
HVAC Final Inspection Plumbing Final Inspection
Residential Electrical Final Inspection Residential Building Final
Plumbing Final Inspection HVAC Final Inspection
Residential Building Final
902 Oak Hill Way
902 Oak Hill Way - New SFR
Inspection Details
bret.stoddard@rexburg.org
Inspected By: Bret Stoddard
Residential Electrical Final Inspection on 08/17/2018: PASS
D ESCRIPTIO N CO M M EN TS STATUS
Check for correction of any deficiencies noted on
previous inspections.
COMPLETED
Positioning of boxes intended to be flush with
combustible and noncombustible finished
surfaces. 314.20
COMPLETED
Gaps around boxes in walls. 314.21 COMPLETED
Polarity of devices and luminaires. 200.10(B),
200.11, 410.23, 406.9
COMPLETED
Proper use of connectors and fittings and for
protection of cables. 300.15
COMPLETED
Unused openings in boxes and other enclosures
are closed. 110.12, 314.17(A), 312.5(A)
COMPLETED
Bushings or equivalent protection for cables
entering boxes and other enclosures. 300.4(F),
314.17, 314.42
COMPLETED
Installation of listed equipment for compliance
with manufacturer’s instructions. 110.3(B)
COMPLETED
Disconnecting means on both permanently
connected and cord- and plug-connected
appliances. Article 422 Part III
COMPLETED
Circuits for mechanical equipment have correct
conductor size and overcurrent protection.
Articles 422, 424, 430, and 440
COMPLETED
Spacing of receptacles for walls and countertops,
including islands and peninsulas. 210.52(A) and
(C)
COMPLETED
Countertop receptacles are provided with GFCI
protection. 210.8(A)(6)
COMPLETED
Properly sized circuits are provided for specific
kitchen appliances, such as dishwashers,
disposals, ranges, cooktops, trash compactors,
and the like. 210.23, 422.10
COMPLETED
Page 1 of 2
(Continued)
Permit Number: 17-00662
D ESCRIPTIO N CO MMEN TS STATUS
Bathroom receptacles are GFCI protected.
210.8(A)(1)
COMPLETED
Arc-fault circuit-interrupter (AFCI) protection on
bedroom circuits. 210.12
COMPLETED
Clearances between luminaires and storage
spaces if luminaires are installed. 410.8
COMPLETED
Proper receptacle ratings based on branch-circuit
ratings, including receptacles for electric dryers.
210.21, 210.24, 250.140
COMPLETED
GFCI protection at laundry sink locations within
6’. 210.8(A)(7)
COMPLETED
At least one receptacle outlet is provided in
unfinished basement areas in addition to any
receptacles installed for laundry equipment and
is GFCI protected. 210.52(G), 210.8(A)(5)
COMPLETED
Receptacle outlet is provided for servicing
mechanical equipment. 210.63
COMPLETED
Wall-switch-controlled lighting outlet or a lighting
outlet containing a switch is provided at the
entrance to equipment requiring servicing.
210.70(A)(3)
COMPLETED
Outdoor receptacles are GFCI protected unless
they are not readily accessible and are supplied
by circuits for deicing or snow-melting
equipment(GFPE required otherwise with a
disconnecting means-breaker lock). 210.8(A)(3),
426.28, 426.50(A)
COMPLETED
Proper identification of all overcurrent devices
and disconnects. 110.22, 230.70(B), 408.4
COMPLETED
Open spaces in panelboard fronts. 110.12 COMPLETED
Approved for a Final and C.O.For a final and C.O.-items corrected from prior
inspection, finished basement entirely, A/C unit
installed. Two receptacles not installed on both
sides of the fireplace in the kitchen/dining area,
please call for a re-inspect when done.
COMPLETED
Page 2 of 2
Inspection
Ticket
Plumbing Final Inspection on 08/17/2018: FAIL
Permit Number: 17-00662Permit Details
Building - Single Family Residence
Permit Issued Date: 11/27/2017
Final Inspections Required
HVAC Final Inspection Plumbing Final Inspection
Residential Electrical Final Inspection Residential Building Final
Plumbing Final Inspection HVAC Final Inspection
Residential Building Final
902 Oak Hill Way
902 Oak Hill Way - New SFR
Inspection Details
don.allen@rexburg.org
Inspected By: Don Allen
Plumbing Final Inspection on 08/17/2018: FAIL
D ESCRIPTIO N CO M M EN TS STATUS
Approved for a Final and C.O.Need access panel for the jetted tub installed FAIL
Inspection
Ticket
HVAC Final Inspection on 08/17/2018: FAIL
Permit Number: 17-00662Permit Details
Building - Single Family Residence
Permit Issued Date: 11/27/2017
Final Inspections Required
HVAC Final Inspection Plumbing Final Inspection
Residential Electrical Final Inspection Residential Building Final
Plumbing Final Inspection HVAC Final Inspection
Residential Building Final
902 Oak Hill Way
902 Oak Hill Way - New SFR
Inspection Details
don.allen@rexburg.org
Inspected By: Don Allen
HVAC Final Inspection on 08/17/2018: FAIL
D ESCRIPTIO N CO M M EN TS STATUS
Approved for a Final and C.O.Need to know what the vent behind the
fireplace is for. Need to check with building
code for having access to the fireplace in the
garage.
FAIL
Inspection
Ticket
Residential Building Final on 08/17/2018: FAIL
Permit Number: 17-00662Permit Details
Building - Single Family Residence
Permit Issued Date: 11/27/2017
Final Inspections Required
HVAC Final Inspection Plumbing Final Inspection
Residential Electrical Final Inspection Residential Building Final
Plumbing Final Inspection HVAC Final Inspection
Residential Building Final
902 Oak Hill Way
902 Oak Hill Way - New SFR
Inspection Details
larry.beesley@rexburg.org
Inspected By: Larry Beesley
Residential Building Final on 08/17/2018: FAIL
D ESCRIPTIO N CO M M EN TS STATUS
Insulation Certificate provided?NO
Approved for a Final in noted levels.N/A
Are As-Built Plans required?N/A
Check for house number FAIL
Exterior egress components (driveways,
sidewalks, ramps, etc.) completed
FAIL
Landscaping and other exterior construction
activities completed or properly separated
Grading around the concrete will need to be
completed when the concrete is all completed.
Also drain and grading by basement walkout
door in the back.
FAIL
mechanical, electrical, plumbing and P&Z finals
are completed
FAIL
Approved for a Final and C.O.FAIL
All egress components (ramps, landings, stairs,
handrails, guardrails, etc.) meet code
COMPLETED
Doors are correct size, swing, and rating COMPLETED
Safety glazing is provided in required locations COMPLETED
Foam insulation is covered as per code COMPLETED
Exterior Stucco or EIFS installed as per code COMPLETED
All building construction is complete COMPLETED
Adequate slope and drainage from foundation
(including drainage tiles, basins, vaults, etc.)
COMPLETED
Page 1 of 2
(Continued)
Permit Number: 17-00662
D ESCRIPTIO N CO MMEN TS STATUS
Smoke detectors working properly and in right
locations
COMPLETED
Smoke & C.O detector outside bedrooms COMPLETED
Ladders in window wells (one in basement or
one in each bedroom window well)
COMPLETED
Gas water heater have two straps: top & bottom COMPLETED
Exterior landings, risers, & treads are proper size COMPLETED
Garage step risers & treads are correct COMPLETED
Handrails for landings & steps COMPLETED
Inspector Comments
The access in the garage behind the fire place is is not allowed unless it has a 26 Gage metal access door or panel
covering the opening and sealed. The concrete driveway and sidewalks all need to be completed before occupancy is
permitted. Adjust the self closing hinges on the garage door. Make all corrections and call for re inspections. Thanks,
Larry
Page 2 of 2