Loading...
HomeMy WebLinkAboutINSPECTION TICKET 1 - 18-00386 - 485 N 2nd E - Mongolian Restaurant - RemodelInspection Ticket Commercial Electrical Final Inspection on 10/02/2018: FAIL Permit Number: 18-00386Permit Details Commercial Remodel Permit Issued Date: 08/03/2018 Final Inspections Required Commercial Electrical Final Inspection HVAC Final Inspection Commercial Building Final 485 N 2nd E Mongolian Restaurant - Remodel Inspection Details bret.stoddard@rexburg.org Inspected By: Bret Stoddard Commercial Electrical Final Inspection on 10/02/2018: FAIL D ESCRIPTIO N CO M M EN TS STATUS Approved for a Final and C.O.Need to provide GFCI protection for the receptacle under the kitchen hood near the grill, dishwasher not wired in and must be GFCI protected also, please call for a re-inspect when done. FAIL Receptacles have correct polarity, grounding, no open neutrals, etc. 200.10(B) COMPLETED Verify that interrupting ratings are adequate for the conditions of the installation. 110.9 COMPLETED Verify that unused openings have been effectively closed.110.12(A), 408.7 COMPLETED Check adequacy of entrance to and exit from working space in general and verify that spaces containing large equipment have at least two entrances/exits. 110.26(C), 110.26(C)(2) COMPLETED Check for identification of disconnecting means and circuit directories for panelboards, switchboards, and similar equipment.110.22, 408.4 COMPLETED Check for continuity and completeness in metal raceways and enclosures. 300.10 COMPLETED Check for adequate length of free conductors in boxes. Verify that boxes are installed at junction, splice, outlet, switch, and pull points.300.14, 300.15 COMPLETED Identify wet and damp locations and the suitability of boxes and fittings.314.15 COMPLETED Check boxes and conduit bodies for adequate space for conductors.314.16 COMPLETED Verify that raceways and cables are secured to boxes.314.17(B) and (C) COMPLETED Check for closure of unused openings.314.17(A)COMPLETED Page 1 of 2 (Continued) Permit Number: 18-00386 D ESCRIPTIO N CO MMEN TS STATUS Verify that boxes in walls and ceilings are flush with the finished surface or, if surfaces are noncombustible, within 1/4 in. of the finished surface.314.20 COMPLETED Check for excessive gaps between edges of boxes and plaster, plasterboard, or drywall surfaces.314.21 COMPLETED Verify that boxes are securely fastened and supported.314.23 COMPLETED Check for covers on boxes.314.25, 314.28(C)COMPLETED Check lighting outlet boxes for suitability.314.27(A) and (B) COMPLETED Verify that all boxes are accessible. 314.29 COMPLETED Verify that switches are located not over 6 ft 7 in. (2 m) high and that they can be operated from readily accessible places unless otherwise permitted.404.8(A), 240.24(A) COMPLETED Verify that the voltage between adjacent grouped or ganged devices is not over 300 volts or that barriers are installed .404.8(B) COMPLETED Verify that switches or receptacles in boxes have their plaster ears seated against the wall surface or the box.404.10(B), 406.4(A) and (B) COMPLETED Verify that switches and receptacles are used within their ratings.404.14, 406.2(A), 430.109 COMPLETED Check the listing and marking of any switches or receptacles used with aluminum conductors. 404.14(C),406.2(C), 110.14 COMPLETED Check receptacles in wet or damp locations for proper covers and enclosures.406.8 COMPLETED Check receptacles for proper polarity and for grounding and bonding connections. 406.3, 250.146, 200.11 COMPLETED Verify that receptacle ratings and branch-circuit ratings are compatible. 210.21, 210.24 COMPLETED Verify that wiring methods are securely fastened in place, supported independently of suspended ceilings, and not used as supports.300.11 and applicable Chapter 3 article(s) APPROVED Page 2 of 2