HomeMy WebLinkAboutBUILDING REVIEW REPORT - 18-00528 - 859 S Yellowstone Hwy - Dr Coray Office - New BuildingReview
Report
Current Building Review Status: REVISIONS
Application Number: 18-00528Permit Details
Application Received Date: 09/24/2018
Building - Commercial
Application Approved Date:
Application Approved Status: ACCEPTED
09/24/2018
859 S Yellowstone Hwy
Dr Coray Office - New Building
Status of Plan Reviews Completed
09/24/2018Electrical Review REVISIONS
09/26/2018Fire Department Review - Site Plan COMPLETED
09/27/2018Planning and Zoning Review - Site Plan REVISIONS
09/28/2018Public Works Review - Site Plan APPW/COND
10/02/2018Plumbing Review COMPLETED
10/02/2018HVAC Review COMPLETED
10/02/2018Building Review REVISIONS
Permit Review Status
Plan Reviews Still in Progress
Electrical Review
Planning and Zoning Review - Site Plan
Building Review
DESCRIPTION COMMENTS STA TUS
*Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed!
Exterior Walls and Coverings comply with IBC
Chapter 14
REVISIONSAssembly type details are missing description
notes.
*Revisions Response :
Toilets, Bathing Fac., Sinks, Kit. and Drink. Fount.
meet IBC Sec. 1109
REVISIONSGrab bar locations to match requirements of
A117.1, 604.5.
*Revisions Response :
Glass and Glazing meets the requirements of IBC
Chapter 24
REVISIONSTempered windows are not identified.
*Revisions Response :
Building complies with IECC (IBC 1301)* R-49 attic insulation (approved)
* R-22 exterior wall insulation (approved)
* Window and door U-factor shall be 0.51
maximum (not noted)
* Foundation insulation shall go extend from top
of foundation.
COMPLETED
Reviewed By: Quinton Owens
Review Date: 10/02/2018
Plan Review Details
quinton.owens@rexburg.org
Building Review Status: REVISIONS
Page 1 of 2
Approval of plans does not constitue approval of variance from code
Building Review (Continued)
D ESCRIPTIO N CO MMEN TS STATUS
Service Facilities comply with IBC 1109.12 Reception desk elevation is not identified.
* For accessibility, service/reception counters
shall be no more than 36" above floor for a
length of at least 36" (parallel approach) or 30"
(forward approach).
COMPLETED
Concealed spaces are fireblocked/draftstopped
per Section 718
Fire blocking per IBC 718 will be approved
based on inspection
COMPLETED
Exit Lighting and Exit Signs comply with IBC 1008
& 1013
Eliminate exit sign on lobby side of door going
into shell space and on shell space side of door
going into back corridor.
COMPLETED
Page 2 of 2
Approval of plans does not constitue approval of variance from code