Loading...
HomeMy WebLinkAboutBUILDING REVIEW REPORT - 18-00528 - 859 S Yellowstone Hwy - Dr Coray Office - New BuildingReview Report Current Building Review Status: REVISIONS Application Number: 18-00528Permit Details Application Received Date: 09/24/2018 Building - Commercial Application Approved Date: Application Approved Status: ACCEPTED 09/24/2018 859 S Yellowstone Hwy Dr Coray Office - New Building Status of Plan Reviews Completed 09/24/2018Electrical Review REVISIONS 09/26/2018Fire Department Review - Site Plan COMPLETED 09/27/2018Planning and Zoning Review - Site Plan REVISIONS 09/28/2018Public Works Review - Site Plan APPW/COND 10/02/2018Plumbing Review COMPLETED 10/02/2018HVAC Review COMPLETED 10/02/2018Building Review REVISIONS Permit Review Status Plan Reviews Still in Progress Electrical Review Planning and Zoning Review - Site Plan Building Review DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Exterior Walls and Coverings comply with IBC Chapter 14 REVISIONSAssembly type details are missing description notes. *Revisions Response : Toilets, Bathing Fac., Sinks, Kit. and Drink. Fount. meet IBC Sec. 1109 REVISIONSGrab bar locations to match requirements of A117.1, 604.5. *Revisions Response : Glass and Glazing meets the requirements of IBC Chapter 24 REVISIONSTempered windows are not identified. *Revisions Response : Building complies with IECC (IBC 1301)* R-49 attic insulation (approved) * R-22 exterior wall insulation (approved) * Window and door U-factor shall be 0.51 maximum (not noted) * Foundation insulation shall go extend from top of foundation. COMPLETED Reviewed By: Quinton Owens Review Date: 10/02/2018 Plan Review Details quinton.owens@rexburg.org Building Review Status: REVISIONS Page 1 of 2 Approval of plans does not constitue approval of variance from code Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Service Facilities comply with IBC 1109.12 Reception desk elevation is not identified. * For accessibility, service/reception counters shall be no more than 36" above floor for a length of at least 36" (parallel approach) or 30" (forward approach). COMPLETED Concealed spaces are fireblocked/draftstopped per Section 718 Fire blocking per IBC 718 will be approved based on inspection COMPLETED Exit Lighting and Exit Signs comply with IBC 1008 & 1013 Eliminate exit sign on lobby side of door going into shell space and on shell space side of door going into back corridor. COMPLETED Page 2 of 2 Approval of plans does not constitue approval of variance from code