Loading...
HomeMy WebLinkAboutBUILDING REVIEW REPORT - 18-00514 - 596 Angela Dr - SFR AdditionReview Report Current Residential Building Review Status: APPROVED Application Number: 18-00514Permit Details Application Received Date: 09/12/2018 Single Family Residential Addition Application Approved Date: Application Approved Status: ACCEPTED 09/12/2018 596 Angela Dr 596 Angela Dr - SFR Addition Status of Plan Reviews Completed 09/27/2018Residential Building Review COMPLETED Permit Review Status Plan Reviews Still in Progress DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Single Family Residential YESAddition on the back of the house. Duplex (LDR1 only - CUP?)YES Flood Plain NO All rebar is tied in place with proper lap?COMPLETED Rebar is correct size and spaced as per plans?COMPLETED Rebar is a minimum or 1" from forms?COMPLETED Foundation walls w/ rebar (city ordinance)COMPLETED 1/2" Anchor bolts with 3" x 3" x 1/4" square washers COMPLETED Foundation Drainage COMPLETED Crawl space access of 18" x 24" min. R408.3 COMPLETED Crawl Space Ventilation/insulation = 1 sf vent per 150 sq. ft. COMPLETED Grading slope away from house. R401.3 COMPLETED Plot Plan COMPLETED To Scale COMPLETED Reviewed By: Larry Beesley Review Date: 09/27/2018 Plan Review Details larry.beesley@rexburg.org Residential Building Review Status: APPROVED Page 1 of 3 Approval of plans does not constitue approval of variance from code Residential Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Legible Missing some things like stud sizes and insulation values. COMPLETED Floor/Foundation Plan COMPLETED Section showing construction details COMPLETED All Building Elevations COMPLETED Design Criteria (identified on plans as Wind-85 mph, Snow-35 lb./sq. ft.) COMPLETED Truss Calculation Sheets The roof is a rafter built roof. the snow load specks. COMPLETED Floor Joist Details COMPLETED Mechanical Design COMPLETED Rear set back (LDR1 25 ft. & LDR2 20 ft.)COMPLETED Proper Size (per Tbl. 403.1, use 1500 psf unless soil type is know, Tbl 401.4.1 COMPLETED Rebar (2-#4 continuous)COMPLETED Footing Depth(36" below fin. grade and 12" below undist. soil; 18" to top of sl COMPLETED Floors joists sized as per R502.3, Wood I-joists sized per manufr. COMPLETED Floor Sheathing (3/4" min for joists, 24" oc & 5/8 for joists 16") R503.2.2 COMPLETED Wall(bearing and nonbearing)stud sizes, hght & spacing per Tbl 602.3(5) R602.3 COMPLETED Headers in Bearing Wall designed as per Tables 502.5(1&2) R602.7 COMPLETED Roof Trusses (desidgned acc. R802.10.1) 35# Snow and 90 mph winds (local cond.) Provide specks on the rafters and snow loads.COMPLETED Rafter and Truss tie-downs R802.10.5 COMPLETED Attic Access 22" x 30" min. opening R807 COMPLETED Masonry & stucco:weather resistive barrier over ext. sheathing R703.2 & . . . COMPLETED Page 2 of 3 Approval of plans does not constitue approval of variance from code Residential Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Roof Ventilation as per R806 COMPLETED Asphalt Shingles(slp>2:12) w/ice protection or Other type to comply w/R905 COMPLETED Interior and exterior stair illumination shall comply with R303.6 COMPLETED Landings at top/bottom of stairway R311.7.5 & each side of each ext. door R311.3 COMPLETED Stair Rise/Run (7 3/4' max. rise & 10" min. tread, nosing req'd if <11") COMPLETED Stair width (36' min)COMPLETED Handrails (34' to 38' above stair nosing)R311.7 COMPLETED Guardrails complying with R312 COMPLETED Vapor retarder on warm in winter side of walls, ceiling and floors R601.3 COMPLETED Plans match quantities & values on a "passing" RES check compliance report I need your Insulation values.COMPLETED Additional Inspector Comments: This project was built without a permit from the beginning. I listed information that I will need before the job is completed and the C.O. is issued. Page 3 of 3 Approval of plans does not constitue approval of variance from code