Loading...
HomeMy WebLinkAboutBUILDING REVIEW REPORT - 18-00595 - 156 N 2nd E - Shelfology Office RemodelReview Report Current Building Review Status: REVISIONS Application Number: 18-00595Permit Details Application Received Date: 10/24/2018 Commercial Remodel Application Approved Date: Application Approved Status: ACCEPTED 10/24/2018 156 N 2nd E 156 N 2nd E - Shelfology office Remodel Status of Plan Reviews Completed 10/24/2018Electrical Review COMPLETED 11/01/2018Building Review REVISIONS 11/05/2018Plumbing Review COMPLETED 11/05/2018HVAC Review COMPLETED Permit Review Status Plan Reviews Still in Progress Building Review DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Checked for linked cases YES Glass and Glazing meets the requirements of IBC Chapter 24 REVISIONSAll glazing within 24 inches from doors shall be tempered. *Revisions Response : Amount of Plumbing Fixtures meets the requirements of IBC Chapter 29 REVISIONSRestroom(s) are not shown. *Revisions Response : Exit Lighting and Exit Signs comply with IBC 1008 & 1013 REVISIONSExisting exit signs and emergency lighting are not shown (if any). They will be required. *Revisions Response : Exits meet the requirements of IBC Sections 1022 and 1006 REVISIONSIdentify all exits and any interior rooms if any. *Revisions Response : Toilets, Bathing Fac., Sinks, Kit. and Drink. Fount. meet IBC Sec. 1109 REVISIONSRestrooms are not identified on plans. Accessible? *Revisions Response : Reviewed By: Quinton Owens Review Date: 11/01/2018 Plan Review Details quinton.owens@rexburg.org Building Review Status: REVISIONS Page 1 of 3 Approval of plans does not constitue approval of variance from code Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Use classification is identified as per IBC Section 302 REVISIONSOffice space (B), Warehouse (S1), Light Manufacturing (F1). Front section of building shows optional use as Furnishing store (M), Event Venue (A). See comments on fire walls and fire barriers & sprinklers. *Revisions Response : Building height and area meets the requirements of IBC Section 500 REVISIONSExisting one story building approximately 17,576 sf * The mixed occupancies in this size building require a sprinkler system unless properly separated by fire walls and fire barriers. *Revisions Response : Mixed use occupancies meet the requirements of IBC Section 508 REVISIONSNo fire rated separation is identified. Building exceeds the allowed area for any of the occupancies shown, except B, without having a sprinkler system. A fire wall will be required or identified if existing. *Revisions Response : Exterior wall openings meet the requirements of IBC Section 705.8 REVISIONSIs there already an easement on the property to the south? Also for exiting the property on the northeast corner? *Revisions Response : Fire walls meet the requirements of IBC Section 706 REVISIONSProper fire walls are required: building type and use does not meet the allowed area. *Revisions Response : Fire barriers meet the requirements of IBC Section 707 REVISIONSNo fire barriers are identified but are required without a sprinkler system. *Revisions Response : Concealed spaces are fireblocked/draftstopped per Section 718 REVISIONSAre roof trusses open? *Revisions Response : Automatic sprinklers are provided or exempted as per IBC Section 903.2 REVISIONSThe light manufacturing space, if it involves woodworking, cannot generate fine dust or a sprinkler system is required. Options are available for discussion. *Revisions Response : Stories without openings are sprinkled as per IBC Section 903.2.11.1 REVISIONSEast end building section does not have openings. Site visit needed for review of existing conditions. *Revisions Response : Page 2 of 3 Approval of plans does not constitue approval of variance from code Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Rated doors and windows comply with Section 716 REVISIONSAny doors in fire rated walls shall also be rated. *Revisions Response : Doors meet the requirements of IBC Section 1010 REVISIONSDoors for the office area egress only are approved as shown (shall meet minimum size requirements). *Revisions Response : Panic Hardware shall be installed as per IBC Section 1010.1.10 N/APanic hardware is N/A for Shelfology but is required for assembly occupancies. Ventilation is provided as per IBC Section 1203 Natural ventilation shall be provided mechanically or through exterior openings. COMPLETED Wood Fram. design. by lice. Eng. and meets. reqs. IBC Chp. 23 or Conv. Li-Frame Non-bearing partitions only to be installed. If changes are made to structural members, additional review will be required. COMPLETED Exit Access meets the requirements of IBC Section 1016 The only interior detailed plan provided is for office area. Exit access from other areas will be verified on inspection. COMPLETED Ducts and dampers meet the requirements of IBC Section 717 As shown on office area drawing, dampers are not required. Although rated wall locations have not been determined yet. COMPLETED Occupant load is identified on plans as per IBC Section 1004 Occupant load is not identified on drawings: * Manufacturing space/warehouse = 22 occupants * Office area = 15 occupants * Front section (not identified or included in this review) COMPLETED Penetrations comply with IBC Section 714 for rated assemblies Penetrations through rated assemblies shall maintain the fire rating of the assembly. COMPLETED Type of construction is identified.Not shown on plans. * Default to V-B (combustible construction) unless identified otherwise. COMPLETED Additional Inspector Comments: Office space looks good for code requirements, but in conjunction with different occupancy types, fire separation walls need to be confirmed Page 3 of 3 Approval of plans does not constitue approval of variance from code