Loading...
HomeMy WebLinkAboutLETTER - 18-00315 - Approx. 1000 N Yellowstone Hwy - The Grove at Thomson Farms - 30 Unit Bldg SALT LAKE CITY 45 West 10000 South, Ste 500 Sandy, UT 84070 P 801.255.0529 LAYTON 1485 W Hillfield Rd, Ste 204 Layton, UT 84041 P 801.547.1100 CEDAR CITY 1870 North Main Street, Ste 104 Cedar City, UT 84721 P 435.865.1453 TOOELE 169 N. Main Street, Unit 1 Tooele, UT 84074 P 435.843.3590 RICHFIELD 225 North 100 East Richfield, UT 84701 P 435.896.2983 A Value-Added Company www.ensigneng.com Aerial Technologies Civil Engineering Structural Design Land Surveying Water Design Building October 30, 2018 Joel Gray Community Development Department 35 North 1st East Rexburg, Idaho 83440 RE: The Grove at Thomson Farms – New Development Response Letter Mr. Gray, Below are Ensign Engineering’s responses to the City of Rexburg Community Development Department’s comments on The Grove at Thomson Farms project plans. 1. Sewer: Connection to mainline. 4” service must tie in ahead of manholes. Sewer connections to mainlines have been updated to connect ahead of manholes. 2. Sewer: Services to lot(s). We understand that this comment was left over and that nothing needs to be addressed on the plans. 3. Water: Connection to main line. Water line on Hwy 33 is 16”. Hot tap existing 16” not cut and install tee. Sheet C-501 and C-503 have been updated to call out existing 16” water line and note to call out Hot tap existing and connect to existing w/ 16”x10” stainless steel tapping sleeve and 10” gate valve. Sheet C-505 has been left to call out Install 16”x10” TEE with (2) 16” butterfly valves and (1) 10” gate valve per conversation with Joel on October 25th. 4. Storm: Catch basin type. Catch basin head/grate to be Neenah R-3067 in city streets. Neenah R-3067 has been added to all catch basins head/grates on public streets. 5. Storm: Infiltrators. Piping between catch basins cannot be under the curb. Pipe is not required to be RCP pipe. Storm Drain Cleanout boxes have been added to move pipes out from under curb and gutter on public streets. 6. Site Lighting: Photometric layout. No lighting on plans. City streets require lights at all intersections and not more than 400 ft between lights. This sheet has now been included. SALT LAKE CITY 45 West 10000 South, Ste 500 Sandy, UT 84070 P 801.255.0529 LAYTON 1485 W Hillfield Rd, Ste 204 Layton, UT 84041 P 801.547.1100 CEDAR CITY 1870 North Main Street, Ste 104 Cedar City, UT 84721 P 435.865.1453 TOOELE 169 N. Main Street, Unit 1 Tooele, UT 84074 P 435.843.3590 RICHFIELD 225 North 100 East Richfield, UT 84701 P 435.896.2983 Value-Added Company www.ensigneng.com Page 2 7. Water: Pipe Type. Use class 50 ductile iron not class 52. All callouts referencing class 52 ductile iron pipe have been replaced to call out class 50 ductile iron pipe. 8. Storm: On-site retention. Not piping between catch basin under curb. It was our understanding that this only applies to storm drain systems within the public right-of-way. As such we have left these unchanged. 9. Miscellaneous Review. Area at northwest corner states City doing work but should say the work is to be coordinated with City. Note has been updated to “Improvements within this area are to be coordinated with Rexburg City”. 10. Miscellaneous Review. Idaho PE Stamp not Utah Stamp. Idaho PE Stamp has replaced the incorrectly used Utah Stamp. Please contact me if you have additional questions. Sincerely, Jared Ford, P.E. jford@ensignutah.com Ensign Engineering and Land Surveying 45 West 10000 South, Suite 500 Sandy, UT 84070 Ph: 801-255-0529 • Fax:801-255-4449