HomeMy WebLinkAboutINSPECTION SUMMARY - 18-00093 - Navex GlobalPermit Inspection Summary Permit Status of (Open) as of Report Date: 10/08/2018 8:09 am Permit Details Permit Number: 18-00093 Navex Global 155 W 2nd S Commercial Tenant Finish Permit Issued Date: 04/19/2018 Permit Inspection Statistics 35Total Inspections Completed: 8Total Inspections Passed: Inspection Pass Rate: 22.86% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/22/2018PARTPASSTed DyeCommercial Insulation Inspection 05/23/2018PARTPASSTed DyeCommercial Insulation Inspection 05/24/2018PARTPASSTed DyeCommercial Sheetrock/Drywall Inspection 05/31/2018PARTPASSQuinton OwensCommercial Insulation Inspection Remaining insulation in tenant space east of lobby installed and approved to cover. Also looked at rated penetrations above west side restrooms (6 penetrations found unprotected - Failed) Inspector Comments: Restrooms at lobby on 2nd floor are shown to have one hour fire-rated walls. Penetrations above dropped ceiling are not rated yet - Do not cover. Inspector Comments: 06/01/2018PARTPASSQuinton OwensCommercial Framing/Structure Inspection Penetrations through concrete slab above in west restrooms are rated and approved for hanging dropped ceiling. Inspector Comments: 06/11/2018PARTPASSTed DyeCommercial Sheetrock/Drywall Inspection 06/11/2018PARTPASSTed DyeCommercial Framing/Structure Inspection 06/13/2018PARTPASSTed DyeCommercial Sheetrock/Drywall Inspection 06/20/2018PassTed DyeCommercial Framing/Structure Inspection Inspection of Steel stud framing and fire caulking of pipes through concrete floor in the chase. Located on the west side of the center stairs. Approved for cover. Inspector Comments: 06/21/2018PARTPASSTed DyeCommercial Sheetrock/Drywall Inspection 06/27/2018PARTPASSQuinton OwensCommercial Insulation Inspection West end shaft insulation and fireblocking in floor by exhaust fan on south wall on second floor was inspected. Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 18-00093 Navex Global 155 W 2nd S Commercial Tenant Finish Permit Status of (Open) as of Report Date: 10/08/2018 8:09 am Permit Inspection Summary 06/29/2018PARTPASSQuinton OwensCommercial Framing/Structure Inspection Inspected penetrations through rated ceiling. * One hole found unused and unprotected in northwest corner room and needs to be rated. * All other ceiling penetrations under apartments have been protected for fire rating. Inspector Comments: 07/03/2018PARTPASSQuinton OwensCommercial Insulation Inspection * South exterior wall (west side) insulated behind pop out for exhaust fan ducts. * Sleeve through floor above is rated in northwest corner room. Inspector Comments: 07/06/2018FailQuinton OwensCommercial Insulation Inspection Verify average thickness to show compliance to energy codes for ceiling insulation R-value. Inspector Comments: ceiling 2nd story lobby before putting on hard lid; AMInspector Comments: 07/13/2018PARTPASSQuinton OwensCommercial Framing/Structure Inspection Approved to hang dropped ceiling in lobby on 2nd floor.Inspector Comments: 07/13/2018PARTPASSQuinton OwensCommercial Insulation Inspection * Foam insulation approved to apply thermal barrier (east half - no ceiling grid). * Patch cutout spots for ceiling grid supports and ceiling tile to be reviewed as a thermal barrier. * Penetrations into stair enclosure above door was fire rated during inspection. Inspector Comments: 07/31/2018PARTPASSQuinton OwensSuspending Ceiling Inspection Suspended ceiling grid inspected in Navex tenant space on west side. Some offices remain to have ceiling grid installed. Inspector Comments: 08/16/2018FailQuinton OwensCommercial Building Final Re-inspection planned for Monday morning for items listed (actual tenant occupancy is planned for Tuesday). Temporary occupancy approved for installing furnishings by tenant. Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 18-00093 Navex Global 155 W 2nd S Commercial Tenant Finish Permit Status of (Open) as of Report Date: 10/08/2018 8:09 am Permit Inspection Summary Electrical Inspection Type 04/11/2018PassBret StoddardCOM & MFR Electrical Service Inspection 04/11/2018PARTPASSBret StoddardCommercial Electrical Rough-in 05/01/2018PARTPASSBret StoddardCommercial Electrical Rough-in 05/29/2018PARTPASSBret StoddardCommercial Electrical Rough-in 06/05/2018PARTPASSBret StoddardCommercial Electrical Rough-in 07/12/2018PARTPASSBret StoddardCommercial Electrical Rough-in 07/31/2018PARTPASSBret StoddardCommercial Electrical Rough-in 08/09/2018FailBret StoddardCommercial Electrical Final Inspection Mike w/Nelson Electric called in an inspection, he said he needed a final inspection, but the electrical rough-in was never inspected as well a temporary electrical service. Late PM Inspector Comments: 08/14/2018PassBret StoddardCommercial Electrical Final Inspection Fire Inspection Type 08/15/2018PassBret StoddardFire Alarm Final Inspection 08/15/2018PassDavid DavisFire Sprinkler Final Inspection Mechanical Inspection Type 05/31/2018PARTPASSDon AllenHVAC Rough-in 08/08/2018PassDon AllenHVAC Final Inspection Plumbing Inspection Type 04/13/2018PARTPASSDon AllenPlumbing Rough-in 07/12/2018PassDon AllenPlumbing Water Good to cover the water lines in the navex part of the building.Inspector Comments: 08/15/2018PassDon AllenPlumbing Final Inspection Inspections Required Fire Alarm Rough-in Electrical Underground Inspection Plumbing Rough-in Fire Department Final Inspection Commercial Sheetrock/Drywall Inspection Fire Sprinkler Rough-in Commercial Insulation Inspection Commercial Framing/Structure Inspection Suspending Ceiling Inspection Commercial Building Final Page 3 of 3