HomeMy WebLinkAboutROOF SPECS - 18-00641 - 1011 Westwood Dr - Solar ArrayNAME Wade Bowman
LOCATION Rexburg, ID, 83440
MODULE Q. Cells :Q.PEAK DUO BLK-G5 310 (32mm)
DIMENSIONS 66.34" x 39.37" x 1.26" (1,685 x 1,000 x 32mm)
DATE 2018-11-02
TOTAL MODULES 15
TOTAL WATTS 4,650
ATTACHMENT PTS 54
Load Assumptions
WIND EXPOSURE B
WIND SPEED 120 mph
GROUND SNOW LOAD 50 psf
ATTACHMENT SPACING 4.0 ft
Building Details
ROOF SLOPE 22 deg
BUILDING HEIGHT 25 ft
RISK CATEGORY I
XR100 SPAN DETAILS (Landscape)
Roof Zone Max Span Max Cantilever
1 6' 3"2' 6"
2 6' 3"2' 6"
3 6' 3"2' 6"
MAXIMUM REACTION FORCES (Landscape)
Roof Zone Down Uplift Lateral
1 202.00 -68.00 72.00
2 202.00 -138.00 72.00
3 202.00 -217.00 72.00
System Weight
TOTAL WEIGHT 862 lbs
WEIGHT/ATTACHMENT 16.0 lbs
DISTRIBUTED WEIGHT 3.1 psf
RACKING WEIGHT 244.1 lbs
Project Details
Engineering
Last updated by Thomas Simms on 2018-11-01 20:46:21 -0700 Page 1 of 8
Wade Bowman
PITCHED ROOF
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Array Details
Array Cols Rows Orientation Row Length Cantilever Violations Provided Rails Attachments Clamps Splices
A 1 3 LANDSCAPE 5' 8.3"10"None 84'[6 x 14']12 12 0
9' 10"
5' 8"
Last updated by Thomas Simms on 2018-11-01 20:46:21 -0700 Page 2 of 8
Wade Bowman
PITCHED ROOF
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Array Cols Rows Orientation Row Length Cantilever Violations Provided Rails Attachments Clamps Splices
B 1 4 LANDSCAPE 5' 8.3"10"None 112'[8 x 14']16 16 0
13' 2"
5' 8"
Last updated by Thomas Simms on 2018-11-01 20:46:21 -0700 Page 3 of 8
Wade Bowman
PITCHED ROOF
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Array Cols Rows Orientation Row Length Cantilever Violations Provided Rails Attachments Clamps Splices
C 3 2 LANDSCAPE 16' 9.8"5"None 68'[4 x 17']20 16 0
C 2 1 LANDSCAPE 11' 3.1"1' 8"None 28'[2 x 14']6 6 0
9' 10"
16' 10"
Last updated by Thomas Simms on 2018-11-01 20:46:21 -0700 Page 4 of 8
Wade Bowman
PITCHED ROOF
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Note: The images displayed in this report are meant to represent one portion of the array. The use of a break line indicates that the array may continue on beyond that point.
Last updated by Thomas Simms on 2018-11-01 20:46:21 -0700 Page 5 of 8
Wade Bowman
PITCHED ROOF
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Splice Detail
XR100
SIDE-FACING SLOT
INTERNAL SPLICE
TOP-FACING SLOT
Splice Connection
INTERNAL SPLICE
RAIL
SELF-DRIVING SCREW
Clamp Detail
Mid Clamp, Plan
UNIVERSAL FASTENING OBJECT
PV MODULE FRAME
Mid Clamp, Front
RAIL
PV MODULEFRAME
UNIVERSALFASTENINGOBJECT
End Clamp, Plan
STOPPERSLEEVE
UNIVERSALFASTENINGOBJECT
PV MODULEFRAME
RAIL
1”
End Clamp, Front
PV MODULEFRAME
RAIL
UNIVERSALFASTENINGOBJECT
STOPPERSLEEVE1”
Last updated by Thomas Simms on 2018-11-01 20:46:21 -0700 Page 6 of 8
Wade Bowman
PITCHED ROOF
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Grounding Diagram
UFO Grounding Lug Minimum 10 AWGCopper Wire
Fault Current Ground Path
Bonded Splice (Rail Connection)
**
*Grounding Lugs and wire are not required in systems using certain Enphase microinverters or certain Sunpower modules. Equipment grounding is achieved with the Engage cable for Enphase or the AC module cable system for Sunpower via their integrated EGC.
CAMO orUFO orCAMO
Last updated by Thomas Simms on 2018-11-01 20:46:21 -0700 Page 7 of 8
Wade Bowman
PITCHED ROOF
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545
Bill of Materials
GROUP PART DESCRIPTION TOTAL QTY
RAILS & SPLICES XR-100-168B XR100, Rail 168" (14 Feet) Black 16
XR-100-204B XR100, Rail 204" (17 Feet) Black 4
CLAMPS & GROUNDING UFO-CL-01-B1 Universal Module Clamp, Black 50
UFO-STP-32MM-B1 Stopper Sleeve, 32MM, Black 40
XR-LUG-03-A1 Grounding Lug, Low Profile 10
ATTACHMENTS LFT-03-B1 Slotted L-Foot, Black 54
BHW-TB-02-A1 T-Bolt Bonding Hardware 54
ACCESSORIES XR-100-CAP Kit, End Cap XR100 (10 sets per bag)2
29-4000-077 Wire Clips, Molded PVC Black, Polybag 20 2
BHW-MI-01-A1 Microinverter Bonding Hardware, T-Bolt 15
Last updated by Thomas Simms on 2018-11-01 20:46:21 -0700 Page 8 of 8
Wade Bowman
PITCHED ROOF
28357 INDUSTRIAL BLVD., HAYWARD, CA 94545