HomeMy WebLinkAboutQ-CELL DUO - 18-00641 - 1011 Westwood Dr - Solar ArrayWade Bowman 1011 Wesrwood Drive Rexburg, ID 83440 Valuation $19,763 1P. Manufacturer:QCELL Duo 310 Model:SolarEdge SE5000 Bus Rating:200amp # Of Modules In Series:15 Module:310 Max power output @ STC:5000 Main Breaker:200amp Total # of Strings 1 Rated AC Volatage:240 Service type:Underground Total # Of Modules Per Inverter:15 Solar Breaker or fuses size 30 Sevice Upgrade NO Ratted Power Output @ STC:5000 1 12/2 MC cable with ground (3)#8 THWN (1)#10 Ground 3/4" EMT or 3/4" Ridge or 3/4" Seal-Tight #6 Solid copper ground #10 PV Wire 3/4" EMT (2) #10 Thwn and (1) #10 ground Wade Bowman 1011 Wesrwood Drive Rexburg, ID 83440 2P.PV Modules STC Details@ STC:Inverter UL Approved Rattings @ STC Existing Electrical Conditions: Wade Bowman PV System Over Values 1. existing meter main with 200A rated bussing 1.1 . Interconnection will be made with a 30A 2-pole breaker placed in the furthest available position 2.30A Eaton DG322URB Safety Switch, 240V, 2Pole Sevice Rated, NEMA 3R Or Equal , Fused with 30A fuses 3. SE5000 Inverter equipped with rapid shutdown 4. Hoffman A6R66 Enclosure, NEMA 3R,Screw Cover, 6" x 6" x 6", Painted, Kos 5.Sola Deck 0783-41 PV Roof-Mount Enclosure 6.1 Strings of solar QCELL Duo 310 modules with (1 P-320 optimizer per panel ) 1.123456 1 LEGEND 4" long 4" long WARNING ! WARNING ELECTRIC SHOCK HAZARD ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED,2"2"DO NOT TOUCH TERMINALS NORMALLY GROUNDED CONDUCTORS tall tall TERMINALS ON BOTH LINE AND MAY BE UNGROUNDED AND ENERGIZED LOAD SIDES MAY BE ENERGIZED WARNING: PHOTOVOLTAIC IN THE OPEN POSITION POWER SOURCE PLACED ON THE INVERTER, OR PLACED NEAR PLACED ON OR ADJACENT TO PLACED EVERY 10' ON CONDUIT THE GROUND-FAULT INDICATOR AT A VISIBLE LOCATION THE DISCONNECTING MEANS 4"long 3 1/4" long 4"long MAIN PHOTOVOLTAIC 1" PHOTOVOLTAIC SYSTEM AC DISCONNECT 1"RAPID SHUTDOWN SYSTEM AC DISCONNECT COMBINED OPERATING RATING: 21A 1"tall DISCONNECT SWITCH AMPS RATED OUTPUT VOLTAGE: 240 VAC tall LOCATED ON THE DC DISCONNECT LOCATED ON THE AC DISCONNECT LOCATED ON MAIN SERVICE PANEL PORTION OF THE INVERTER 3 1/4" long 4 1/2" long PHOTOVOLTAIC SYSTEM DC DISCONNECT WARNING INVERTER OUTPUT CONNECTION RATED MPP CURRENT: 13.5ADC DO NOT RELOCATE THIS OVERCURRENT DEVICE RATED MPP VOLTAGE: 350 VDC 1 1/2" MAXIMUM SYSTEM VOLTAGE: 480.1VDC Tall PLACED NEXT TO THE SOLAR BREAKER SHORT CIRCUIT CURRENT: 45 ADC LOCATED ON INVERTER PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID 2 1/4" SHUTDOWN Tall 6 3/4" long Wade Bowman 1011 Wesrwood Drive Rexburg, ID 83440 P.3 Existing 200 amp Meter & Subpanel New Disconnect SE5000 Wade Bowman 1011 Wesrwood Drive Rexburg, ID 83440 Clearance P.4 3' & 18" Fire Wade Bowman 1011 Wesrwood Drive Rexburg, ID 83440 5P. Wade Bowman 1011 Wesrwood Drive Rexburg, ID 83440 P.6