Loading...
HomeMy WebLinkAboutMATERIAL INFO - 18-00558 - 1376 Stone Dr - New SFR23'7" 23'7" 1 Hanger (MIU3.56/11 (Min))2 Hanger (MIU3.56/11 (Max)) 3 1/2" 11 7/8" 1 Client:Sunroc Building Materials Project: Address: Date:7/6/2018 Designer:Reeve & Associates, Inc. (801.621.3100) Job Name:Lot 3 Sky Meadows Project #: Level: LevelFJ 23.7 SS RFPI 90 11.875"-PASSED EWP Studio Version 18.32.085 Powered by iStruct Member Information Type:Joist Spacing:12" o.c. Moisture Condition:Dry Deflection LL:480 Deflection TL:240 Importance: Normal Temperature: Temp <= 100°F Application:Floor Design Method:ASD Building Code:IBC/IRC 2015 Load Sharing: No Deck:3/4 APA Rated Sturd-I- FloorOSB Nailed and Glued Ceiling:Gypsum 1/2" Reactions UNPATTERNED lb (Uplift) Brg Live Dead Snow Wind Const 1 472 177 0 0 0 2 472 177 0 0 0 Analysis Results Analysis Actual Location Allowed Capacity Comb.Case Moment 3730 ft-lb 11'9 1/2"10145 ft-lb 0.368 (37%)D+L L Shear 641 lb 1 3/4"2050 lb 0.312 (31%)D+L L LL Defl inch 0.398 (L/702)11'9 9/16"0.582 (L/480)0.680 (68%)L L TL Defl inch 0.547 (L/511)11'9 9/16"1.165 (L/240)0.470 (47%)D+L L Bearings Bearing Length Cap.React D/L lb Total Ld. Case Ld. Comb. 1 - Hanger 2.500"42%177 / 472 649 L D+L 2 - Hanger 2.500"42%177 / 472 649 L D+L Design Notes 1 Fill all hanger nailing holes. ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments 1 Uniform 1-0-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF EWP StudioSimpson Strong-Tie®Component Solutions Roseburg Forest Products 4500 Riddle By-pass Rd Riddle, OR 97469 (541) 784-4005www.roseburg.comAPA: PR-L259, ICC-ES: ESR-1251 Manufacturer InfoNotes Calculated Structured Designs is responsible only of the structural adequacy of this component based on the design criteria and loadings shown. It is the responsibility of the customer and/or the contractor to ensure the component suitability of the intended application, and to verify the dimensions and loads. Lumber 1.2.Dry service conditions, unless noted otherwiseIJoist not to be treated with fire retardant or corrosive chemicals Handling & Installation 1.2. 3.4. IJoist flanges must not be cut or drilledRefer to latest copy of the IJoist product information details for framing details, stiffener tables, web hole chart, bridging details, multi-ply fastening details and handling/erection detailsDamaged IJoists must not be usedDesign assumes top flange to be laterally restrained by attached sheathing or as specified in engineering notes. 5. 6. 7. Provide lateral support at bearing points to avoid lateral displacement and rotationWeb stiffeners for point load as shown Minimum point load bearing length>= 3.5 inchesFor flat roofs provide proper drainage to prevent ponding Page 1 of 1