Loading...
HomeMy WebLinkAboutPRODUCT DATA - SPRINKLER HEADS UPRIGHT - 18-00176 - 220 S 2nd W - Arbor Cove - Bldg (C) #2 - 32 Units - New Dormitory Housingwww.reliablesprinkler.com Product Description Model J112 and JL112 series sprinklers are cULus Listed extended coverage spray sprinklers intended for installation in accordance with NFPA 13. The sprinklers also have cU- Lus Listed Specific Application Criteria for installation under concrete tee construction in accordance with the require- ments documented in this bulletin. Coverage areas up to 400 ft2 (37 m2) per sprinkler with a maximum spacing of up to 20 ft by 20 ft (6.1 m by 6.1 m) are permitted for both Light Hazard and Ordinary Hazard occupancies. Listed flows and pressures for each hazard classification and sprinkler spac- ing are provided in this bulletin. Model J112 and JL112 se- ries sprinkler are cULus Listed as quick-response sprinklers for Light Hazard occupancies. When used in the Ordinary Hazard occupancies, Model J112 and JL112 series sprin- klers are cULus Listed as quick-response for spacings up to 14 ft by 14 ft (4.3 m by 4.3 m) and standard-response for other listed spacings up to 20 ft by 20 ft (6.1 m by 6.1 m). Model J112 Pendent and J112 Upright sprinklers use a glass bulb operating element and are cULus Listed as Corrosion Resistant Sprinklers when ordered with White Polyester, Black Polyester, or Electroless Nickel PTFE (ENT) finish. Model JL112 Pendent and JL112 Upright sprinklers use a fusible link operating element. Model J112 Pendent and Model JL112 Pendent sprinklers are cULus Listed for use with the Model F2 and Model FP recessed escutch- eons, which provide up to ½ inch (13 mm) of adjustment. In addition, for Ordinary Hazard occupancies, the Model J112 Pendent and Model JL112 Pendent sprinklers are cULus Listed for use with the Model F1 recessed escutcheon that provides up to ¾ inch (19 mm) of adjustment. Application Model J112 and JL112 series sprinklers are intended for installation in Light Hazard and Ordinary Hazard occupan- cies in accordance with NFPA 13. The sprinklers must be installed in accordance with the requirements of NFPA 13 for extended coverage spray sprinklers and the require- ments identified in this bulletin. In addition to the installation requirements of NFPA 13, cULus Listed Specific Application Criteria for installation under concrete tee construction is provided in this bulletin. Model J112 and JL112 Sprinklers Bulletin 172 Rev. G June 2018 cULus Listed K11.2 (160 metric)Extended Coverage Sprinklers for Light Hazard and Ordinary Hazard Model J112 UprightModel JL112 Upright Model J112 PendentModel JL112 Pendent Model J112 and JL112 Series Sprinkler Summary Model Orientation Operating Element Sprinkler Identification Number (SIN) J112 Pendent Glass Bulb RA7216 JL112 Pendent Fusible Link R7216 J112 Upright Glass Bulb RA7326 JL112 Upright Fusible Link R7326 Table A FP Recessed EscutcheonF1/F2 Recessed Escutcheon Bulletin 172 Rev. G June 2018 Page 2 of 7 www.reliablesprinkler.com Model J112 Pendent Sprinkler SIN RA7216 Technical Specifications Style: Extended Coverage Pendent Threads: 3/4” NPT or ISO 7-1R3/4 Nominal K-Factor: 11.2 (160 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Glass Bulb Cup: Bronze Alloy Frame: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Kick Spring: Steel Alloy Deflector: Brass Alloy Sprinkler Wrench Model J1 Model RJ (recessed) Finishes (See Table G) Sensitivity (See Table B) Temperature Ratings 155°F (68°C) 200°F (93°C) Recessed Escutcheons F1-3/4” (19mm) adjustment (Ordinary Hazard only) F2-1/2” (13mm) adjustment FP-1/2” (13mm) adjustment Listings and Approvals cULus Listed cULus Listed as Corrosion Resistant with White Polyester, Black Polyester, and ENT finish only Max. Spacing ft. x ft.(m x m) Light Hazard Ordinary Hazard Group 1 Ordinary Hazard Group 2 Flow gpm (l/m)Pressure psi (bar)Flow gpm (l/m)Pressure psi (bar)Flow gpm (l/m)Pressure psi (bar) 12 x 12 (3.7 x 3.7) 30 (114) QR 7.2 (0.50) QR 30 (114) QR 7.2 (0.50) QR 39 (148) QR 12.1 (0.8) QR 14 x 14(4.3 x 4.3)30 (114)QR 7.2 (0.50)QR 30 (114)QR 7.2 (0.50)QR 39 (148)QR 12.1 (0.8)QR 16 x 16 (4.9 x 4.9) 30 (114) QR 7.2 (0.50) QR 39 (148) SR 12.1 (0.8) SR 51 (193) SR 20.7 (1.4) SR 18 x 18(5.5 x 5.5)33 (125)QR 8.7 (0.60)QR 49 (186)SR 19.1 (1.3)SR 65 (246)SR 33.7 (2.3)SR 20 x 20 (6.1 x 6.1) 40 (152) QR 12.8 (0.88) QR 60 (227) SR 28.7 (2.0) SR 80 (303) SR 51.0 (3.5) SR Table B QR = Quick-response SR = Standard-response Listed Design Criteria and Sensitivity Model J112 Pendent Sprinkler Components Figure 1 Bulletin 172 Rev. G June 2018 Page 3 of 7 www.reliablesprinkler.com Model JL112 Pendent Sprinkler SIN R7216 Technical Specifications Style: Extended Coverage Pendent Threads: 3/4” NPT or ISO 7-1R3/4 Nominal K-Factor: 11.2 (160 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Frame: Brass Alloy Levers: Brass Alloy Cap: Bronze Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Brass Alloy Strut: Copper Alloy Sprinkler Wrench Model J1 Model RJ (recessed) Finishes (See Table G) Sensitivity (See Table C) Temperature Rating* 165°F (74°C) 212°F (100°C) Recessed Escutcheons F1-3/4” (19mm) adjustment (Ordinary Hazard only) F2-1/2” (13mm) adjustment FP-1/2” (13mm) adjustment Listings and Approvals cULus Listed *Chrome and white polyester finish is supplied with white link regardless of temperature rating Max. Spacing ft. x ft.(m x m) Light Hazard Ordinary Hazard Group 1 Ordinary Hazard Group 2 Flow gpm (l/m) Pressure psi (bar) Flow gpm (l/m) Pressure psi (bar) Flow gpm (l/m) Pressure psi (bar) 12 x 12 (3.7 x 3.7) 30 (114) QR 7.2 (0.50) QR 30 (114) QR 7.2 (0.50) QR 39 (148) QR 12.1 (0.8) QR 14 x 14(4.3 x 4.3)30 (114)QR 7.2 (0.50)QR 30 (114)QR 7.2 (0.50)QR 39 (148)QR 12.1 (0.8)QR 16 x 16 (4.9 x 4.9) 30 (114) QR 7.2 (0.50) QR 39 (148) SR 12.1 (0.8) SR 51 (193) SR 20.7 (1.4) SR 18 x 18(5.5 x 5.5)33 (125)QR 8.7 (0.60)QR 49 (186)SR 19.1 (1.3)SR 65 (246)SR 33.7 (2.3)SR 20 x 20 (6.1 x 6.1) 40 (152) QR 12.8 (0.88) QR 60 (227) SR 28.7 (2.0) SR 80 (303) SR 51.0 (3.5) SR Table C QR = Quick-response SR = Standard-response Listed Design Criteria and Sensitivity Model J112 Pendent Sprinkler Components Figure 2 Bulletin 172 Rev. G June 2018 Page 4 of 7 www.reliablesprinkler.com Model J112 Upright Sprinkler SIN RA7326 Technical Specifications Style: Extended Coverage Upright Threads: 3/4” NPT or ISO 7-1 R3/4 Nominal K-Factor: 11.2 (160 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Glass Bulb Cup: Bronze Alloy Frame: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Kick Spring: Steel Alloy Deflector: Brass Alloy Finishes (See Table G) Sensitivity (See Table D) Temperature Rating 155°F (68°C) 200°F (93°C) Sprinkler Wrench Model J1 Listings and Approvals cULus Listed cULus Listed as Corrosion Resistant with White Polyester, Black Polyester, and ENT finish only Max. Spacing ft. x ft.(m x m) Light Hazard Ordinary Hazard Group 1 Ordinary Hazard Group 2 Flow gpm (l/m) Pressure psi (bar) Flow gpm (l/m) Pressure psi (bar) Flow gpm (l/m) Pressure psi (bar) 12 x 12 (3.7 x 3.7) 30 (114) QR 7.2 (0.50) QR 30 (114) QR 7.2 (0.50) QR 39 (148) QR 12.1 (0.8) QR 14 x 14(4.3 x 4.3)30 (114)QR 7.2 (0.50)QR 30 (114)QR 7.2 (0.50)QR 39 (148)QR 12.1 (0.8)QR 16 x 16 (4.9 x 4.9) 30 (114) QR 7.2 (0.50) QR 39 (148) SR 12.1 (0.8) SR 51 (193) SR 20.7 (1.4) SR 18 x 18(5.5 x 5.5)33 (125)QR 8.7 (0.60)QR 49 (186)SR 19.1 (1.3)SR 65 (246)SR 33.7 (2.3)SR 20 x 20 (6.1 x 6.1) 40 (152) QR 12.8 (0.88) QR 60 (227) SR 28.7 (2.0) SR 80 (303) SR 51.0 (3.5) SR Table D QR = Quick-response SR = Standard-response Listed Design Criteria and Sensitivity Model J112 Upright Sprinkler Components Figure 3 Bulletin 172 Rev. GJune 2018 Page 5 of 7www.reliablesprinkler.com Model JL112 Upright Sprinkler SIN R7326 Technical Specifications Style: Extended Coverage Upright Threads: 3/4” NPT or ISO 7-1 R3/4 Nominal K-Factor: 11.2 (160 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Frame: Brass Alloy Levers: Brass Alloy Strut: Brass Alloy Cap: Bronze Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Brass Alloy Finishes (See Table G) Sensitivity (See Table E) Temperature Rating* 165°F (74°C) 212°F (100°C) Sprinkler Wrench Model J1 Listings and Approvals cULus Listed *Chrome and white polyester finish is supplied with white link regardless of temperature rating Max. Spacing ft. x ft. (m x m) Light Hazard Ordinary Hazard Group 1 Ordinary Hazard Group 2 Flow gpm (l/m) Pressure psi (bar) Flow gpm (l/m) Pressure psi (bar) Flow gpm (l/m) Pressure psi (bar) 12 x 12 (3.7 x 3.7) 30 (114) QR 7.2 (0.50) QR 30 (114) QR 7.2 (0.50) QR 39 (148) QR 12.1 (0.8) QR 14 x 14 (4.3 x 4.3) 30 (114) QR 7.2 (0.50) QR 30 (114) QR 7.2 (0.50) QR 39 (148) QR 12.1 (0.8) QR 16 x 16 (4.9 x 4.9) 30 (114) QR 7.2 (0.50) QR 39 (148) SR 12.1 (0.8) SR 51 (193) SR 20.7 (1.4) SR 18 x 18 (5.5 x 5.5) 33 (125) QR 8.7 (0.60) QR 49 (186) SR 19.1 (1.3) SR 65 (246) SR 33.7 (2.3) SR 20 x 20 (6.1 x 6.1) 40 (152) QR 12.8 (0.88) QR 60 (227) SR 28.7 (2.0) SR 80 (303) SR 51.0 (3.5) SR Table E QR = Quick-response SR = Standard-response Listed Design Criteria and Sensitivity Model JL112 Upright Sprinkler Components Figure 4 Note: The Model FP, F1, or F2 may be used for ordinary hazard occupancies. For light hazard occupancies, the Model FP or F2 recessed escutcheon must be used. Model J112 and JL112 sprinklers with Model F1 recessed escutcheon are not listed for use in light hazard occupancies. Bulletin 172 Rev. GJune 2018 Page 6 of 7www.reliablesprinkler.com The Model J112 and JL112 pendent and upright sprinklers are cULus Listed for installation under concrete tee construction in ac- cordance with the following specific application criteria: • Max. Tee Depth: 2’- 6” (0.8m) • Max. Tee Stem Spacing: 7’- 6” (2.3m) • Min. Tee Stem Spacing: 3’- 0” (0.9m) • Max. Tee Length: 32’- 0” (9.8m) or baffles not less than the depth of the tees must be installed so that the longitudinal space between baffles does not exceed 32ft (9.8m) in length. • Max. Deflector distance below Tee: 1” (25mm) • Comply with obstructions to the Sprinkler Discharge Pattern Development requirements of the NFPA13 where deflector is lo- cated above bottom of tee. Model J112 and JL112 Specific Application Criteria for Use Under Concrete Tee Construction cULus Listed Figure 7Model F1/F2 Escutcheon Installation DimensionsFigure 6Model FP Escutcheon Installation Dimensions Figure 5Application and Installation for Use Under Concrete Tee 1” (25mm) max. 1” (25mm) max. 2’-6” (0.8m) max. 7’-6” (2.3m) max.3’-0” (0.9m) min. P / N 9 9 9 9 9 7 0 3 1 0 Bulletin 172 Rev. G June 2018 Page 7 of 7 www.reliablesprinkler.com Installation Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. Re- liable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb pro- tector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protec- tors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Models J112 and JL112 series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this bulletin. Any other wrench may damage the sprinkler. Recom- mended installation torque is 14 to 20 lb.ft (19 to 27 N.m). Do not tighten sprinklers over the maximum recommended installa- tion torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed pendent sprinklers are to be installed as shown in Fig. 6 or Fig 7., as applicable to the specific model being in- stalled. Models J112 and JL112 series recessed pendent sprin- klers may only be installed with the Reliable Model F1, Model F2, or Model FP recessed escutcheon. The use of any other recessed escutcheon will void all approvals and negate all war- ranties. The Reliable Model FP escutcheon may not be used in ceilings having positive pressure with respect to the space below. Ensure that the openings in the Model FP escutcheon/ can assembly are unobstructed following installation. Maintenance Models J112 and JL112 series sprinklers should be inspect- ed and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammo- nia or any other cleaning fluids. Remove dust by gentle vacu- uming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging un- til used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. J1 Wrench RJ Wrench Table G Sprinkler Finishes Special Application Sprinkler Finishes Sprinkler F1, F2, & FP(3) Escutcheons Sprinkler F1, F2, & FP(3) Escutcheons Bronze Chrome Plated White Polyester (2) Brass Chrome Plated White Polyester Bright Brass Dull Chrome Black Polyester (2) Custom Color Polyester Electroless Nickel PTFE (2) (4) Bright Brass Dull Chrome Black Polyester Custom Color Polyester Type 316 Stainless Steel Sprinkler & Escutcheon Finishes (1) Notes: (1) Paint or any other coating applied over the factory finish will void all approvals and warranties. (2) cULus Listed Corrosion Resistant when ordered with Model J112 Pendent (RA7216) or Model J112 Upright (RA7326). (3) The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. (4) Available with Model J112 Pendent (RA7216) and Model J112 Upright (RA7326) only. Listings and Approvals Listed by Underwriters Laboratories, Inc. and certified by Underwriters Laboratories of Canada (cULus) UL Listing Category Sprinklers, Automatic and Open Extended Coverage Sprinklers UL Guide Number – VNIV. Ordering Information Specify: 1. Sprinkler Model: [J112 Pendent] [JL112 Pendent] [J112 Upright] [JL112 Upright] 2. Temperature Rating: J112: [155°F (68°C)] [200°F (93°C)] JL112: [165°F (74°C)] [212°F (100°C)] 3. Finish: (See Table G) 4. Escutcheon (Pendent Only; for 3/4” threads) Model F1 (Ordinary Hazard Only) Model F2 Model FP