Loading...
HomeMy WebLinkAboutPRODUCT DATA - HANGING MATERIAL ANVIL LONGITUDINAL CLAMP - 18-00176 - 220 S 2nd W - Arbor Cove - Bldg (C) #2 - 32 Units - New Dormitory HousingPROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: SEISMIC BRACES PH-1.18 q Fig. AF411 (Formerly Afcon Fig. 411) Longitudinal Seismic Clamp q Fig. AF074 (Formerly Afcon Fig. 074) Brace Attachment Fitting q Fig. AF078 (Formerly Afcon Fig. 078) Brace Attachment Fitting Size Range: Service Pipe: 1" through 10" Carbon Steel Brace Pipe: 1" through 2" Sch. 40 Material: Carbon Steel (AF074 Only: Ductile Iron Brace Socket) Finish: q Plain or q Electro-Galvanized per ASTM B633 Service: Designed to rigidly brace piping systems subjected to longitudinal seismic loads. The Fig. AF411 may be installed with Fig. AF074 or AF078 Brace Attachment Fittings. Approvals: cULus Listed (UL 203a) and FM Approved (FM 1950-10 & FM 1950-13). Complies with the hanging and bracing requirements listed in NFPA 13. Features: Visual indication of assembly when the clamp ears make metal-to-metal contact. Installation Instructions: • Mount the Fig. AF074 or AF078 on the outside of the outside of the Fig. AF411 clamps ears. • Position the clamp at the desired location on the service pipe and hand tighten the hex bolts. • Insert brace pipe into the AF074 or AF078 socket and torque the set screw until the head bottoms out on the AF074 or AF078. Brace pipe must extend 1/2" past the end of the brace socket. • Ensure the brace pipe is set to the desired installation brace angle. • Tighten the clamp bolts and nuts equally and alternately until metal-to-metal contact is achieved and the nuts are wrench tight. • Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes. Ordering: AF411: Specify service pipe size, figure number, finish, and description. AF074 & AF078: Specify brace pipe size, figure number, finish, and description. AF411, AF074, & AF078 all sold separately. Fig. AF411 Fig. AF074 Fig. AF078 Notes: Anvil International® brand bracing components are designed to be compatible ONLY with other Anvil International® brand bracing components, resulting in a Listed seismic bracing assembly. Updated UL listing information may be viewed at www.ul.com and updated FM approval information may be viewed at www.approvalguide.com. Disclaimer: Anvil International (“Anvil”) does not provide any warranties and specifically disclaims any liability whatsoever with respect to Anvil bracing products and components that are used in combination with products, parts or systems not manufactured or sold by Anvil. In no event shall Anvil be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non-Anvil bracing components have been, or are used. SeisBrace® Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com SEISMIC BRACES PH-1.18 Fig. AF411 (Formerly Afcon Fig. 411) Longitudinal Seismic ClampFig. AF074 (Formerly Afcon Fig. 074) Brace Attachment FittingFig. AF078 (Formerly Afcon Fig. 078) Brace Attachment Fitting FIG. AF411 cULus MAX SEISMIC LONGITUDINAL LOADS: DIMENSIONS (IN) • LOADS (LBS) ServicePipe size BraceAttachment Fitting BracePipe Size Max Seismic Brace Load Sch. 10 Sch. 40 1 AF074 1 – 2 ––2015 AF078 1 – 11/4 ––1000 11/4 – 4 AF074 1 – 2 2015 2015 AF078 1 – 11/4 1000 1000 6 – 8 AF074 1 – 2 2015 2015 Fig. AF411 Fig. AF074 Fig AF078 Service Pipe Brace Pipe Fig AF411 & AF074 Installation Fig AF411 & AF078 Installation FIG. AF411: DIMENSIONS (IN) • WEIGHT (LBS) ServicePipe Size A B Weight 1 55⁄8 21⁄8 1.75 11⁄4 6 21⁄4 1.90 11⁄2 61⁄8 21⁄4 2.00 2 63⁄4 21⁄2 2.15 21⁄2 73⁄8 27⁄8 2.40 3 77⁄8 31⁄8 2.60 4 9 37⁄8 3.10 6 111⁄2 47⁄8 4.50 8 131⁄2 57⁄8 5.50 FIG. AF074 & AF078: DIMENSIONS (IN) • WEIGHT (LBS) BracePipe AF074 AF078 C D Weight C D Weight 1 23⁄16 17⁄16 0.97 25⁄16 11⁄8 0.38 11⁄4 1.07 0.54 11⁄2 1.17 2 1.31 A B C D C D SEISMIC BRACES PH-1.18 Fig. AF411 (Formerly Afcon Fig. 411) Longitudinal Seismic ClampFig. AF074 (Formerly Afcon Fig. 074) Brace Attachment FittingFig. AF078 (Formerly Afcon Fig. 078) Brace Attachment Fitting FIG. AF411 FM MAX SEISMIC LONGITUDINAL ASD LOADS***: DIMENSIONS (IN) • LOADS (LBS) • ANGLES (DEG) ServicePipe Size PipeSchedules BraceAttachment Fitting BracePipe Size Max Seismic Brace Load at Brace Pipe Angle** 30-44 45-59 60-74 75-90 1 – 11/2 Sch. 10 – Sch. 40 AF074 1 – 2 1070 420 510 570 AF078 1 – 11/4 430 420 510 570 2 LW – Sch. 40 AF074 1 – 2 1410 1900 1730 1930 AF078 1 – 11/4 430 620 760 840 21/2 – 3 LW – Sch. 40 AF074 1 – 2 1000 860 1030 1150 AF078 1 – 11/4 430 620 760 840 4 LW AF074 1 – 2 1000 860 1030 1150 AF078 1 – 11/4 430 620 760 840 Sch. 10 – Sch. 40 AF074 1 – 2 1000 950 1150 1280 AF078 1 – 11/4 430 620 760 840 6 LW – Sch. 40 AF074 1 – 2 1410 2000 2450 2740 AF078 1 – 11/4 430 620 760 840 8 Sch. 10 – Sch. 40 AF074 1 – 2 1410 1250 1510 1690 AF078 1 – 11/4 430 620 760 840 * Load rating for LW above refers to FM Approved Lightwall pipe, commonly referred to as Sch.7 and Flow Pipe. See FM Approval Guide for approved Lightwall pipe. ** Brace Pipe Angles are determined from vertical. *** The allowable FM approved capacity of brace subassemblies are listed in Allowable Stress Design (ASD). For Load Resistance Factor Design (LRFD) capacities, the above values will need to be multiplied by 1.5.