HomeMy WebLinkAboutPRODUCT DATA - SPRINKLER HEADS CORRIDOR - 18-00176 - 220 S 2nd W - Arbor Cove - Bldg (C) #2 - 32 Units - New Dormitory HousingModel LT56 Series Special Sprinklers Designed specifically for corridors and hallways K5.6 (80 Metric) cULus Listed Bulletin 058 Rev. B November 2016 Model LT56C Models LT56 & LT56-300 Models LT56L & LT56L-300 Product Features • 28 ft x 10 ft (8.5 m x 3 m) max. coverage area • cULus Listed for Light Hazard occupancies • Increased spacing and reduced water demand in corridors compared with traditional extended coverage sprinklers Product Description Model LT56 series sprinklers are cULus Listed Specific Ap- plication sprinklers designed for installation in accordance with NFPA 13. The sprinklers produce a spray pattern that is specifically designed to cover long narrow spaces, such as corridors and hallways, with fewer sprinklers and less wa- ter demand compared with traditional extended coverage sprinklers. Model LT56 series sprinklers are quick-response sprinklers for use in Light Hazard occupancies only. Model LT56 and Model LT56-300 sprinklers have a glass bulb operating ele- ment. Model LT56L, LT56L-300, and LT56C sprinklers have a fusible link operating element. Model LT56, LT56-300, LT56L, and LT56L-300 sprinklers are available with Model FV recessed escutcheons, Model FP recessed escutch- eons, or Model CCP concealed cover plates. Model LT56C sprinklers require a Model G4 flat concealed cover plate. Sprinkler Model Operating Element Max. Working Pressure psi (bar) Styles Coverage Areas Sprinkler Identification Number (SIN) LT56 Glass Bulb 250 (17.2) Pendent, Recessed Pendent or Conical Concealed Pendent Table B RA5814 LT56L Fusible Link 250 (17.2)Table C R5814 LT56-300 Glass Bulb 300 (21)Table D RA5914 LT56L-300 Fusible Link 300 (21)Table E R5914 LT56C Fusible Link 175 (12)Flat Concealed Table F RA5994 Table A www.reliablesprinkler.com Model LT56C Sprinkler with Model G4 Flat Cover Plate Model FV EscutcheonModel FV Escutcheon Model FP Escutcheon Model FP Escutcheon Model CCP Cover Plate Bulletin 058 Rev. B November 2016 Page 2 of 10 www.reliablesprinkler.com Model LT56 Specific Application Sprinkler SIN RA5814 Technical Specifications Style: Pendent, Recessed Pendent, or Conical Concealed Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 250 psi (17.2 bar) Min. Spacing: 14 ft. (4.3 m) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Sprinkler Finishes (See Table H) Sensitivity Quick-response Temperature Ratings 155°F (68°C) 200°F (93°C) Recessed Escutcheons/Cover Plates Model FV recessed escutcheon Model FP recessed escutcheon Model CCP cover plate Sprinkler Wrenches Model D (pendent) Model GFR2 (recessed and concealed) Listings and Approvals cULus Listed Model LT56 Sprinkler Components and Dimensions Figure 1 Model LT56 Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure Max. Coverage Area ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 28 x 8 (8.5 x 2.4) 23 (87) 16.9 (1.17) 28 x 10 (8.5 x 3.0) 28 (106) 25.0 (1.72) Note: For coverage area dimensions less than or between those listed above, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Bulletin 058 Rev. B November 2016 Page 3 of 10 www.reliablesprinkler.com Model LT56L Specific Application Sprinkler SIN R5814 Technical Specifications Style: Pendent, Recessed Pendent, or Conical Concealed Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 250 psi (17.2 bar) Min. Spacing: 14 ft. (4.3 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Sprinkler Finishes (See Table H) Sensitivity Quick-response Temperature Ratings 165°F (74°C) 212°F (100°C) Recessed Escutcheons/Cover Plates Model FV recessed escutcheon Model FP recessed escutcheon Model CCP cover plate Sprinkler Wrenches Model D (pendent) Model GFR2 (recessed and concealed) Listings and Approvals cULus Listed Model LT56L Sprinkler Components and Dimensions Figure 2 Model LT56L Sprinkler Hydraulic Design Criteria Table C Minimum Flow and Residual Pressure Max. Coverage Area ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 28 x 8 (8.5 x 2.4) 23 (87) 16.9 (1.17) 28 x 10 (8.5 x 3.0) 28 (106) 25.0 (1.72) Note: For coverage area dimensions less than or between those listed above, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Model LT56-300 Specific Application Sprinkler SIN RA5914 Technical Specifications Style: Pendent, Recessed Pendent, or Conical Concealed Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 300 psi (21 bar) Min. Spacing: 14 ft. (4.3 m) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Sprinkler Finishes (See Table H) Sensitivity Quick-response Temperature Ratings 155°F (68°C) 200°F (93°C) Recessed Escutcheons/Cover Plates Model FV recessed escutcheon Model FP recessed escutcheon Model CCP cover plate Sprinkler Wrenches Model D (pendent) Model GFR2 (recessed and concealed) Listings and Approvals cULus Listed Model LT56-300 Sprinkler Components and Dimensions Figure 3 Model LT56-300 Sprinkler Hydraulic Design Criteria Table D Minimum Flow and Residual Pressure Max. Coverage Area ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 28 x 8 (8.5 x 2.4) 23 (87) 16.9 (1.17) 28 x 10 (8.5 x 3.0) 28 (106) 25.0 (1.72) Note: For coverage area dimensions less than or between those listed above, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Bulletin 058 Rev. B November 2016 Page 4 of 10 www.reliablesprinkler.com Model LT56L-300 Specific Application Sprinkler SIN R5914 Technical Specifications Style: Pendent, Recessed Pendent, or Conical Concealed Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 300 psi (21 bar) Min. Spacing: 14 ft. (4.3 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Sprinkler Finishes (See Table H) Sensitivity Quick-response Temperature Ratings 165°F (74°C) 212°F (100°C) Recessed Escutcheons/Cover Plates Model FV recessed escutcheon Model FP recessed escutcheon Model CCP cover plate Sprinkler Wrenches Model D (pendent) Model GFR2 (recessed and concealed) Listings and Approvals cULus Listed Model LT56L-300 Sprinkler Components and Dimensions Figure 4 Model LT56L-300 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure Max. Coverage Area ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 28 x 8 (8.5 x 2.4) 23 (87) 16.9 (1.17) 28 x 10 (8.5 x 3.0) 28 (106) 25.0 (1.72) Note: For coverage area dimensions less than or between those listed above, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Bulletin 058 Rev. B November 2016 Page 5 of 10 www.reliablesprinkler.com Model LT56C Specific Application Sprinkler SIN RA5994 Technical Specifications Style: Flat Cover Plate Concealed Pendent Threads: 1/2” NPT or ISO 7-1 R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 14 ft. (4.3 m) Material SpecificationsThermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFELoad Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sprinkler Finishes (See Table H) Sensitivity Quick-response Temperature Ratings 165°F (74°C) 212°F (100°C) Cover Plate Model G4 Sprinkler Wrench Model FC Listings and Approvals cULus Listed Model LT56C Sprinkler Components and Dimensions Figure 5 Model LT56C Sprinkler Hydraulic Design Criteria Table F Minimum Flow and Residual Pressure Max. Coverage Area ft. x ft. (m x m) Flow gpm (l/min) Pressure psi (bar) 28 x 8 (8.5 x 2.4) 24 (91) 18.4 (1.27) 28 x 10 (8.5 x 3.0) 28 (106) 25.0 (1.72) Note: For coverage area dimensions less than or between those listed above, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Bulletin 058 Rev. B November 2016 Page 6 of 10 www.reliablesprinkler.com Type Adjustment Inch (mm) Maximum Face of Fitting to Ceiling(1) Inch (mm) Minimum Face of Fitting to Ceiling(1) Inch (mm) Maximum Deflector Distance Below Ceiling Inch (mm) Minimum Deflector Distance Below Ceiling Inch (mm) Cover Plate Temperature °F (°C) FV 1/2 (12) 7/8 (22) 3/8 (10) 1-3/4 (44) 1-1/4 (32)N/A FP 1/2 (12) 1-1/2 (38) 1 (25) 1 (25) 1/2 (12)N/A CCP 135 1/2 (12) 1-1/2 (38) 1 (25) 1 (25) 1/2 (12) 135°F(2) (57°C) CCP 165 1/2 (12) 1-1/2 (38) 1 (25) 1 (25) 1/2 (12) 165°F(3) (74°C) G4 135 3/4 (19) 2-1/4 (57) 1-1/2 (38) 1 (25) 1/4 (6) 135°F(2) (57°C) G4 165 3/4 (19) 2-1/4 (57) 1-1/2 (38) 1 (25) 1/4 (6) 165°F(3) (74°C) Table GRecessed Escutcheon and Conical Concealed Cover Plate Dimensions Notes: 1. Face of fitting to ceiling dimensions are based on nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. 2. For use with 155°F (68°C) and 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). 3. For use with 200°F (93°C) and 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (66°C). Bulletin 058 Rev. B November 2016 Page 7 of 10 www.reliablesprinkler.com Recessed Escutcheon and Concealed Cover Plate Diagrams Figure 6 Standard Finishes Special Application Finishes Sprinkler(1)FV, FP(4) Escutcheons CCP, G4 Cover Plate Sprinkler FV, FP(3) Escutcheons CCP, G4 Cover Plate Bronze Brass Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Chrome Dull White Polyester(3)White Polyester White Paint Black Polyester(3)Black Polyester Black Paint Custom Color Polyester Custom Color Polyester Custom Color Paint Electroless Nickel PTFE(3) Electroless Nickel PTFE Notes: 1. Model LT56, LT56L, LT56-300, and LT56L-300 only. 2. Paint or any other coating applied over the factory finish will void all approvals and warranties. 3. cULus Listed Corrosion Resistant, Models LT56 (RA5814) and LT56-300 (RA5914) only. 4. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Sprinkler, Escutcheon, & Cover Plate Finishes(2) Table H Application Model LT56 series sprinklers are cULus Listed Specific Applica- tion sprinklers for use in Light Hazard corridors and hallways in accordance with NFPA 13. The sprinklers are classified as Spe- cial Sprinklers based on the maximum and minimum allowable spacing, but shall otherwise be designed in accordance with the requirements of NFPA 13 for Extended Coverage Pendent Spray sprinklers. Model LT56 series sprinklers are quick-response sprin- klers for use in Light Hazard occupancies only. The sprinklers must be hydraulically designed using the minimum flow and pressure specified in the Hydraulic Design Criteria ta- bles in this Bulletin. Figure 7 outlines the maximum coverage area of Model LT56 series sprinklers. Figure 8 identifies the sprinklers that can be located adjacent to Model LT56 series sprinklers; note that LT56 series sprinkler are not permitted to be installed with the short coverage length oriented towards the short coverage length of an adjacent LT56 series sprinkler. An example layout of Model LT56 series sprinklers is illustrated in Figure 9. escutcheons, and Model CCP cover plate, are the only recessed escutcheons and concealed cover plate to be used with Mod- el LT56, LT56L, LT56-300 and LT56L-300 sprinklers. The Model G4 cover plate is the only concealed cover plate permitted for use with the Model LT56C sprinkler. Use of any other recessed escutcheon or cover plate will void all approvals and warranties. Do not install Model FV and FP escutcheons or Model CCP and G4 cover plates in ceilings that are positively pressurized with respect to the occupied space below. When installing Model LT56, LT56L, LT56-300, and LT56L-300 sprinklers use only the Model D wrench for pendent installations and the Model GFR2 wrench for recessed pendent and concealed installation. The Model LT56C sprinkler must be installed with the Model FC wrench. Use of wrenches other than those specified may damage these sprinklers. Model LT56 series sprinklers must be installed with the frame arms or towers perpendicular to the length of the corridor or hallway. The deflector is marked with “<-28 FT->” to indicate the direction of the 28 ft. (8.5 m) coverage length. Model LT56 series sprinklers need not be installed with the frame arms or towers parallel to the sprinkler pipe. Recommended installation torque is 8-18 ft-lbs (11 – 24 N-m). Do not tighten sprinklers over the maximum recommended torque. Exceeding the maximum recommended torque may cause leak- age or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove the bulb protector at the time the sprinkler system is placed in service for fire protection. Removal of the bulb protectors before this time may leave the bulb vulnerable to damage. The required sprinkler wrenches are designed to install sprinklers with bulb protectors in place. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove the bulb protectors. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) UL Listing Category Sprinklers, Automatic and Open UL Guide Number VNIV Installation Model LT56 series sprinklers must be installed in accordance with the requirements of the MFPA 13 for pendent sprinklers and may also be installed as a recessed sprinkler or concealed sprinkler as shown in Figure 6. The Model FV and FP recessed Bulletin 058 Rev. BNovember 2016 Page 8 of 10www.reliablesprinkler.com Coverage Area Figure 7 Adjacent Sprinklers Figure 8 Example Sprinkler Layout Figure 9 Bulletin 058 Rev. B November 2016 Page 9 of 10 www.reliablesprinkler.com Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Patent Pending Ordering Information Specify the following when ordering. Sprinkler • Model (LT56, LT56L, LT56-300, LT56L-300, LT56C) • Temperature Rating • Threads (1/2” NPT or ISO 7-1 R1/2) • Finish (See Table H) Escutcheon or Cover Plate • Type (None, FV, FP, CCP, G4) • Finish (See Table H) Sprinkler Wrench • Model D (LT56, LT56L, LT56-300, LT56L-300 Pen dent) • GFR2 (LT56, LT56L, LT56-300, LT56L-300 Re- cessed or Conical Concealed) • FC (LT56C Flat Concealed) Maintenance Reliable Model LT56 series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdic- tion. Prior to installation, sprinklers should remain in the original car- tons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than facto- ry applied). Properly installed Model CCP and Model G4 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Model FV and FP escutcheons as well as Model CCP and Model G4 cover plates have holes in the ring or cup that must remain unobstructed. Replace any sprinkler which has been damaged, cracked the glass bulb, or has lost liquid from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Bulletin 058 Rev. B November 2016 Page 10 of 10 www.reliablesprinkler.com Model LT56, LT56L, LT56-300 and LT56L-300 Sprinklers Model LT56C Sprinklers P/ N 9 9 9 9 9 7 0 4 9 3 Wrench Options Model D Model GRF2 Model FC