HomeMy WebLinkAboutPRODUCT DATA - PIPE & FITTINGS VICTAULIC NO FLEX COUPLING - 18-00176 - 220 S 2nd W - Arbor Cove - Bldg (C) #2 - 32 Units - New Dormitory HousingThe unique angle-pad design of the Zero-Flex® Style 07 coupling adjusts to standard pipe and roll or cut groove tolerances, positively clamping the pipe to resist flexural and torsional loads. The wider key section fills more of the groove area. Style 07 couplings are rated up to 750 psi/5175 kPa, dependant on size, for 1 – 12"/25 – 300 mm piping systems. Style 07 couplings provide rigidity for valve connections, machinery rooms, fire mains, and long straight runs. Support and hanging requirements correspond to ASME B31.1 Power Piping Code, ASME B31.9 Building Services Code and NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/ bolt and scissoring housing over gasket. This reduces the number of components to handle during assembly, speeds and eases installation. For 14 – 24"/350 – 600 mm sizes Victaulic offers the Advanced Groove System (AGS) line of products. Request publication 20.02 for information on the rigid W07 AGS coupling. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel. • Optional: Hot dipped galvanized and others. Coupling Gasket: (specify choice‡) • Grade “E” EPDM (All other sizes) EPDM (Green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade “T” nitrile Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. ‡ Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. 06.02_1 Zero-Flex® Rigid Coupling STYLE 07 06.02IPS CARBON STEEL PIPE – GROOVED COUPLINGS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________ Submitted By ________________________ Spec Sect ____________ Para __________ Location ____________________________ Date ________________________________ Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I Exaggerated for clarity SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS DIMENSIONS Size Max. Work Pressure * Max. End Load * Allow. Pipe End Sep. † Bolt/Nut@ No – Size Dimensions – Inches/mm Approx. Wgt. Each Nominal Size Inches mm Actual Outside Diameter Inches mm psi kPa Lbs. N Inches mmInchesXYZ Lbs. kg 11.3157506500.052 – 3⁄8 x 2 2.36 4.22 1.84 1.6 25 33.7 5175 2890 1.2 60 107 47 0.7 1 ¼ 1.660 750 1,620 0.05 2 – 3⁄8 x 2 2.69 4.62 1.84 1.6 32 42.4 5175 7210 1.2 68 117 47 0.7 1 ½ 1.900 750 2,130 0.05 2 – 3⁄8 x 2 2.94 5.81 1.84 1.6 40 48.3 5175 9480 1.2 75 148 47 0.7 2 2.375 750 3,320 0.07 2 – ½ x 2 ½ 3.35 5.78 1.84 2.3 50 60.3 5175 14775 1.7 85 147 47 1.0 2 ½ 2.875 750 4,875 0.07 2 – ½ x 2 ¾ 3.88 6.38 1.84 2.6 65 73.0 5175 21695 1.7 98 162 47 1.2 76.1 mm 3.000 750 5,300 0.07 2 – 12 x 70.0 4.21 6.61 1.84 3.6 76.1 5175 23585 1.7 107 168 47 1.6 33.5007507,2150.072 – ½ x 2 ½ 4.54 6.81 1.84 3.0 80 88.9 5175 32105 1.7 115 173 47 1.4 44.50075011,9250.162 – ½ x 2 ¾ 5.81 8.21 2.07 5.3 100 114.3 5175 53065 4.1 148 209 53 2.4 108.0 mm 4.250 750 10,635 0.16 2 – 12 x 70.0 5.56 7.98 2.07 5.2 108.0 5175 47325 4.1 141 203 53 2.4 55.56375018,2250.162 – 5⁄8 x 3 ¼ 7.03 9.89 2.07 7.4 125 141.3 5175 81100 4.1 179 251 53 3.4 133.0 mm 5.250 700 15,145 0.16 2 – 16 x 82.5 6.69 9.60 2.07 7.4 133.0 4825 67395 4.1 170 244 53 3.4 139.7 mm 5.500 700 16,625 0.16 2 – 16 x 82.5 6.94 9.82 2.07 7.6 139.7 4825 73980 4.1 176 249 53 3.4 66.62570024,1300.162 – 5⁄8 x 3 ¼ 8.26 10.83 2.07 8.3 150 168.3 4825 107380 4.1 210 275 53 3.8 159.0 mm 6.250 700 21,465 0.16 2 – 16 x 82.5 7.84 10.54 2.07 9.2 159.0 4825 95520 4.1 199 268 53 4.2 165.1 mm 6.500 700 23,225 0.16 2 – 5⁄8 x 3 ¼ 8.13 10.84 2.07 8.3 165.1 4825 103305 4.1 207 275 53 3.8 8 § 8.625 600 35,000 0.19 2 – ¾ x 4 ¼ 10.54 13.74 2.51 15.1 200 219.1 4130 155750 4.8 268 349 64 6.8 10 § 10.750 500 45,400 0.13 2 – 7⁄8 x 6 ½ 12.86 16.98 2.56 23.5 250 273.0 3450 202030 3.3 327 431 65 10.7 12 § 12.750 400 51,000 0.13 2 – 7⁄8 x 6 ½ 14.86 18.88 2.56 28.2 300 323.9 2750 226950 3.3 377 480 65 12.8 14 – 24 350 – 600 For 14 – 24"/350 – 600 mm sizes Victaulic offers the Advanced Groove System (AGS) line of products. Request publication 20.02 for information on the rigid W07 AGS coupling. § Couplings 8, 10, 12"/200, 250, 300 mm sizes available to JIS standard. Refer to section 06.17 for details. * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1½ times the figures shown. † For field installation only on roll grooved pipe or cut grooved pipe. Zero-Flex Style 07 couplings are essentially rigid and do not permit expansion/contraction. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. Style 07 couplings must not be used to join PVC pipe. TMTM Z X Y TYPICAL 1 – 12" 06.02_2 Zero-Flex® Rigid Coupling STYLE 07 06.02IPS CARBON STEEL PIPE – GROOVED COUPLINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. 06.02_3 Zero-Flex® Rigid Coupling STYLE 07 06.02IPS CARBON STEEL PIPE – GROOVED COUPLINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_I WCAS-6ENLLX 06.02 Zero-Flex® Rigid Coupling STYLE 07 IPS CARBON STEEL PIPE – GROOVED COUPLINGS 06.02 1482 REV I UPDATED 11/2006 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 06.02