Loading...
HomeMy WebLinkAboutELEVATIONS - 17-00264 - 1220 Franklin Dr - SFRCo p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 8:12 Main & 10:12 Pitch Front 9' & 10' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP Front Elevation Right Elevation Rear Elevation Left Elevation A1 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO A5 of 03-18-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M ST E V E N S HO M E S TOTAL SQ. FTG.= 4238 MAIN FLOOR=2141 BASEMENT =2097/1881 LIVING COLD STORAGE=50 GARAGE =1175 12 10 12 8 Stucco Vertical Siding Shakes Faux Stone Scale: 1/4" & 1/8" =1'-0" on 36" x 24" Paper Elevations Scale: 1/8" & 1/16"=1'-0" on 17" x 11" Paper DE S I G N + BU I L D P. O . B o x 2 7 5 9 I d a h o F a l l s , I D 8 3 4 0 3 2 0 8 . 2 0 6 . 1 9 1 9 VA L L E Y V I E W 2 ww w . s t e v e n s h o m e s . c o m Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 9' & 10' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP Foundation Plan Scale: 1/4"=1'-0" D Size Paper Scale: 1/8"=1'-0" B Size Paper Ventilation R408.1 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1 2" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & ROUND plate Washer 2 1/2 Ø x1 4" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2012 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2012 IRC Section R106.1 over Undisturbed Soil Window Well System: 2012 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. J Ventilation R408.1 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Smoke Alarms 2012 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms SD Carbon Monoxide Alarms 2012 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM A2A2 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO A5 of 03-18-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M ST E V E N S HO M E S TOTAL SQ. FTG.= 4238 MAIN FLOOR=2141 BASEMENT =2097/1881 LIVING COLD STORAGE=50 GARAGE =1175 DE S I G N + BU I L D P. O . B o x 2 7 5 9 I d a h o F a l l s , I D 8 3 4 0 3 2 0 8 . 2 0 6 . 1 9 1 9 VA L L E Y V I E W 2 ww w . s t e v e n s h o m e s . c o m H1 Room Mechanical FD o Family Area 10 cfm fresh air Theater Room SD 10 cfm fresh air Bedroom FAN 50cfm Bath 10 cfm Fresh Air Living Areas Bedroom SD 10 cfm fresh air 4'-6"7'4'-6"8'24'-3"12'-3" 24'36'-6" 73'-6" 3' - 1 0 " 1' - 6 " 5' 7' - 1 " 7' 14 ' - 1 " 4' - 2 " 6' - 6 " 3' - 1 0 " 12 ' - 9 " 41 ' - 4 " 22 ' - 2 " 63 ' - 6 " 11'10' 8'-6" 29'-6" 1'-10"4'-2" 6' 2' - 4 " 4' - 4 " 2' 4' 11' 3' - 1 0 " 11'-5" 30'-6" 7' - 8 " 16'8' 1' 11 ' - 6 " 22 ' - 8 " 6' - 8 " 28 ' - 8 " 24 ' - 8 " 2' 24 ' - 8 " 17'14' 44'29'-6" 73'-6" 24 ' - 2 " 2468 2868 WH WS Furn. 2668 2868 2668 Linen 2668 26682668 Beam w/ Trim 2868 2668 Cut for 3068 Ext. Door Cut for 9' OH Garage Door 3068 3' - 6 " 3' - 6 " 4' 2' - 3 " 19 ' - 5 " 7' - 6 " 3' - 6 " 4' 7' - 5 " 2' - 8 " 3' - 6 " 4' 3' - 1 0 " 6' - 6 " 13 ' - 1 " 16 ' - 7 " 3' - 1 0 " 8'-5"3'-10"3'-10"19'-11" 8'-5"3'-6" 3'-11"3'-4"9'-9"6'-4"6'-2"4'-2"14'-11" 2868 6'-11"5'3'-10"3'-5"7'-8"3'-10"5'-4" 8'-10" 11 ' 10'-10" 12 ' - 1 0 " 10'-10" 12 ' - 9 " 23'-9" 18 ' - 9 " 13'-10" 2x 6 W a l l 6'-6"6'-6" 13' Cut for 9' OH Garage Door 13' 26 ' - 2 " 6' 30 6 8 4050 SV 4050 SV 4050 SV 9' TRIPLE CAR GARAGE 4" CONCRETE SLAB SLOPE CONC. FLOOR TO DRAIN TO GARAGE DOOR HOLDDOWN: H1 SIMPSON STRONG TIE STHD14-INSTALLED & NAILED AS PER MANUFACTURERS RECOMMENDATIONS CONCRETE TO WOOD CONNECTION 4050 SV 8'-4"7'-8" 6'-5"6'-6"6'5'-4" 8' - 2 " 5'-9"6'-6" 30 6 8 Storage Cold Storage 4050 SV J Exercise Room 26 6 8 CM Unfinished Basement 19'-1" 8'-11" 2" S t o n e Le d g e 2" S t o n e Le d g e 2" S t o n e Le d g e 9' 27 ' - 1 " 7' Game Room 4'-11" 5' - 7 " 3' 2' - 7 " 1/2 Bath Floor Joist Direction Floor Joist Direction Fl o o r J o i s t D i r e c t i o n Fl o o r J o i s t D i r e c t i o n Fl o o r J o i s t D i r e c t i o n Fl o o r J o i s t D i r e c t i o n Fl o o r J o i s t D i r e c t i o n 3' - 1 0 " 22 ' - 4 " H1 9' Basement F. Walls H1 H1H1 H1 H1 H1 11 ' - 2 " T-Wall SD Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 9' & 10' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP Main Floor Scale: 1/4"=1'-0" D Size Paper Scale: 1/8"=1'-0" B Size Paper Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2012 IRC, Section R106 and R311.6 Saftey Glazing 2012 IRC, Sections R106 and R308.4.5 Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Furnace: Location of furnace and water heater 2012 IRC, Section R106, and M1305 Elevate all sources of ignition in the garage a min. of 18" above the floor 2012 IRC, Sections R106, and M1307.3 Provide a protection post in the garage to prevent vehicle damage to furnace and water heater. 2012 IRC, Section R106, M1307.3.1 Crawl Space: Through Floor min 18"x24" or through perimeter wall min 16"x24" required crawl space opening. If applicable, refer to mechanical code for access requirements where mechanical equipment is located under floors. 2012 IRC, Section R106, R408.4 M1305.1.4 Smoke Alarms 2012 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms SD Carbon Monoxide Alarms 2012 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM 4' Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 4' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2012 IRC, Section R106 and R311.6 Saftey Glazing 2012 IRC, Sections R106 and R308.4.5 Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. A3 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO A5 of 03-18-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M ST E V E N S HO M E S TOTAL SQ. FTG.= 4238 MAIN FLOOR=2141 BASEMENT =2097/1881 LIVING COLD STORAGE=50 GARAGE =1175 DE S I G N + BU I L D P. O . B o x 2 7 5 9 I d a h o F a l l s , I D 8 3 4 0 3 2 0 8 . 2 0 6 . 1 9 1 9 VA L L E Y V I E W 2 ww w . s t e v e n s h o m e s . c o m Deck Bath WIC SD SD FAN 50cfm Utility Kitchen FAN 100cfm 20min Fire Rated 1-3/8" Solid Door or Equal 10 cfm fresh air Master Bedroom SD FAN 50cfm Porch Room Dining Entry Bedroom 1 SD 10 cfm fresh air Bedroom 2 SD 10 cfm fresh air Family Area 10 cfm Fresh Air Living Areas Dining Formal Office or Bath FAN 50cfm 4'-6"7'4'-6"8'2'-7"2'-6"2'-6"2'-1"5'-2"5' 10'-2"2'-8"4'-7"4'5'-1" 36'-6"24' 60'-6" 2' - 1 " 4' - 3 " 13 ' - 1 0 " 5' - 4 " 6' - 4 " 2' - 8 " 12 ' - 1 0 " 2' 41 ' 2' - 4 " 20 ' - 2 " 65 ' - 6 " 6'-6"6'-6"3'3'2'-3"2'-3" 13'6'11' 30' 4' 2' 4' - 4 " 3' - 4 " 1' 24 ' - 6 " 3' - 8 " 14' 3'-8"1'-10" 11' 6' - 1 " 3' - 8 " 6' 12 ' - 1 1 " 6' 6' - 8 " 26 ' 22 ' - 1 0 " 63 ' - 6 " 17'14' 31'29'-6" 73'-6" 2' 2' 4'4' 4'4'2'2'8'2'2' 16'8' 5' 2' - 8 " 7' - 8 " SD 2050 SH 6068 Fr Dr 2050 SH (2) 2030 SH DW Ref 2868 2468 2468 3068 2868 Rail 2668 Arch 2068 2068 2868 2668 2668 P 2030 SH 2668 2668 2868 2668 2668 5050 SV2650 Fix2650 Fix 5050 SV 3068 GFP 2868 Arch 2668 2668 10' Ceiling 12'3'-10"2'-8"8'-6"2'-8" 18' 2'-8"3'-8"6'-6" 6'-6"3'-8"2'-8" 7' - 6 " 6' - 4 " 5' - 4 " 4' 5' 8' - 1 0 " 6'-6"3'-8"2'-8"6'-4"10'-8"2' 9'-2"5'-2"3'-7"2'-3"4'4'-6" 8' - 5 " 3' - 1 0 " 3' - 6 " 11 ' - 1 1 " 1' - 8 " 6' - 9 " 3' - 1 0 " 3' - 6 " 4' - 4 " 3' - 6 " 23 ' - 5 " 1' 2' 2'2'2' 10' x 11'-3" 12' x 12'-4" 9'-8" x 13'-4" 18' x 22'-7" 9'-3" x 10'-7" 15' x 14'-1" 13'-2" x 5'-7" 13'-6" x 14'-1" 18 x 8 O H G a r a g e D o o r 9x8 OH Garage Door 6' 3'-6" 2468 Desk 3' - 4 " 2' 40 4 0 4'-9" 13 ' 9' - 6 " 2' - 4 " 18 ' 2' - 6 " 2'9'2' 13' 5'-6" Lo c k e r s 24 6 8 DO 2650 26502650 10' 2'-3"2'-9"2'-9"2'-3" 2050 3'-3"3'-3" 1' - 4 " 1' 2020 T 2020 T 2020 T DN 12 26502650 2650 2650 2650 10' Ceiling 3'-9"3'-9"4'-9"5'-3"3'-6"5'-3" 20502050 4' 3068 3 Car Garage 1237 Square Feet Contractor to locate exact location of req'd 22" x 30" Attic Access Point Min. 30" Vert. Head Room Clearance (2009-R807.1) Pantry 30'-6" 2x 6 W a l l 2x 6 W a l l IBWP 5 5' - 3 " 4' - 1 0 " 28 ' - 8 " IBWP 5 IB W P 5 3' - 6 " Vault into 10' Flat 9' Flat 9' Flat 9' Flat Vaulted Va u l t Va u l t 9' Flat Vaulted Vaulted CMCM SD Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Cross Section Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e Decking System: (if applicable) 2012 IRC, Section R106.1, R311.5, R502.3.1(1), R502.3.1 (2),R507, R703.8 Req. handrail at ext. steps over 2x4 floor decking with Required Spacing over 2x8 Deck Joist Stingers connected to house 2x10 rim-board with angle bolt 2 bolts need to be in top 4 1 2" of Ledger board over 2x10 ledger boards connected by Simpson Joist Hanger anchor over 8Ø x 24" deep conc. pier over 8x16x16 conc. footing with req. horizontal and vertical rebar over undisturbed soil. K Taped and Prep'd for Interior Finishes over 1/2" Sheetrock on Ceiling Side Foundation Wall System: Min. (2) Anchor Bolts per Sill Plate w/nut & Max. 12" from all Corners or Splices with 1/2" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded ROUND Plate Washer 2 1/2Ø x1/4" Min. for ea. Bolt over Concrete Foundation Wall Consistant w/2012 IRC R401-403 with Asphalt Emulsion on Exterior Side Consistant w/2012 IRC Section R106.1 over Continuous Concrete Footings connected to Rim Joist, spliced using gal. metal ties over Undisturbed Soil 2x6 Treated Sill Plate over Foam Sill Sealer fastened w/6 16d nails ea. side not less than .058" x 1.5" wide G 2012 IRC, Section R106 and R308.4.5 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field Taped Prep'd for Interior Finishes Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) over 11-7/8 TJI Engineered Floor Joist 3/4" T&G OSB Sub-floor Glued & Nailed 2012 IRC Code R106.1 2x4 Stud framed @ 24" O.C. Floor System: 2012 IRC Code with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides with min. R-21 Batt Insulation 2012 IRC Code Interior Walls: with 1/2" Sheetrock Inside Occupancy separation between with (1) 2x6 Bottom Plate with (2) 2x6 Top Plates 2x6 Stud framed @ 24" O.C. UNO 2x6 Fascia Board with 3" Continuous Soffit Venting with add'l 2x4 Support as Required Exterior Walls: with 3/8" Soffit Sheeting with style "D" Metal Drip Edge 2012 IRC Code Soffit System: A C E D B Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 15 23 12 12 17 12 12 16 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Smoke Alarms 2012 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms S Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Carbon Monoxide Alarms 2012 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fastners for Preservative treated wood Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasterners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the front line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Ventilation 2012 IRC, Section R408.1, R408.2, and R408.3 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 300 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Taped Prep'd for Interior Finishes CM between house, attic, and garage Window Well System: 2012 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. J with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes Basement Furring: with 6-Mill Poly Vapor Barrier with (2) 2x4 Top Plates 2x4 Stud Framed @ 24" O.C. with Baring Walls @ 16" O.C. with R-13 Batt Insulation with (1) 2x4 Bottom Plate F 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Max. Wall Height 8' 9' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 Cross Section Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper Fasten sheathing to header w 8d common or gal. box nails in 3" grid pattern as shown Header to jack-stud strap per table R602.10.6.4 on both sides of opening opposite side of sheathing Min. Length of panel per Table R602.10.5 Min. double 2x4 framing covered w min. 7 16" thick wood structual panel sheathing w 8d common or gal. box nails at 3" o.c. in framing (studs and sills) as shown. typ. Min. (2) 4200 LB Tie-Down Device (Embedded into Concrete and Nailed into Framing) (1) 5 8" Ø Anchor Bolts R403.1.6 with 2"x2"x316" plate washer Min. Double 2x4 Post Typical Portal Frame Construction If needed, panel splice edges shall occur over & be nailed to common blocking w/in middle 24" of wall mid-height. One row of 3" o.c. nailing is req. in ea. panel edgeMin. 1000LB Tie down Device Extent of Header Single Portal Frame (One Braced Wall Panel) Extent of Header Double Portal Frame (Two Braced Wall Panels) Ma x H e i g h t 1 0 ' - 0 " MIN. WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS Table R602.10.6.1 Seismic Design Category and Windspeed Tie-Down Force (lb.) 8 ft. 2'-4" 9 ft. 2'-8" 10 ft. 2'-8" 11 ft. 3'-2" 12 ft. 3'-6" SDC A,B, and C Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 1800 3000 2000 3300 2200 3600 SDC D,D, and D Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 1800 3000 - - 0 1 2 2'-8"2'-8"2'-8"Note a Note a - - Height of Braced Wall Panel Sheathed Width Sheathed Width Alternate Braced Wall Panel Garage Portal Design Figure R602.10.6.4 11" Min Run on Conc. Step into house Max Rise 7 3/4" Concrete Steps into House Decking System: (if applicable) 2012 IRC, Section R106.1, R311.5, R502.3.1(1), R502.3.1 (2),R507, R703.8 Req. handrail at ext. steps over 2x4 floor decking with Required Spacing over 2x8 Deck Joist Stingers connected to house 2x10 rim-board with angle bolt 2 bolts need to be in top 4 1 2" of Ledger board over 2x10 ledger boards connected by Simpson Joist Hanger anchor over 8Ø x 24" deep conc. pier over 8x16x16 conc. footing with req. horizontal and vertical rebar over undisturbed soil. K Taped and Prep'd for Interior Finishes over 1/2" Sheetrock on Ceiling Side Foundation Wall System: Min. (2) Anchor Bolts per Sill Plate w/nut & Max. 12" from all Corners or Splices with 1/2" Anchor Bolts @ 72" O.C. 10" Long over Concrete Foundation Wall Consistant w/2012 IRC R401-403 with Asphalt Emulsion on Exterior Side Consistant w/2012 IRC Section R106.1 over Continuous Concrete Footings connected to Rim Joist, spliced using gal. metal ties over Undisturbed Soil 2x6 Treated Sill Plate over Foam Sill Sealer fastened w/6 16d nails ea. side not less than .058" x 1.5" wide G Roof System: 2012 IRC Code Architectural Grade, 25 year Asphalt Shingles over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 8:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2012 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall Taped Prep'd for Interior Finishes Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) over 11-7/8 TJI Engineered Floor Joist 3/4" T&G OSB Sub-floor Glued & Nailed 2x4 Stud framed @ 24" O.C. Floor System: 2012 IRC Code with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides 2012 IRC Code Interior Walls: 2x6 Fascia Board with 3" Continuous Soffit Venting with add'l 2x4 Support as Required with 3/8" Soffit Sheeting with style "D" Metal Drip Edge 2012 IRC Code Soffit System: A E D B Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 12 16 12 12 12 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Smoke Alarms 2012 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms S Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Carbon Monoxide Alarms 2012 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fastners for Preservative treated wood Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasterners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the front line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Ventilation 2012 IRC, Section R408.1, R408.2, and R408.3 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 300 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. CM with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes Basement Furring: with 6-Mill Poly Vapor Barrier with (2) 2x4 Top Plates 2x4 Stud Framed @ 24" O.C. with Baring Walls @ 16" O.C. with R-13 Batt Insulation with (1) 2x4 Bottom Plate F Min. 3"x11 14" net header (Steel header prohibited) Ma x T o t a l W a l l H e i g h t 1 2 ' - 0 " Table R602.10.5 MIN. LENGTH OF BRACED WALL PANELS Min. reinforcing of foundation, (1) #4 bar top & bottom of footing. Lap bars 15" min.Min. Footing under opening is 12"x12" 2'-18" finished width for single or double portal Wall height 8ft 9ft 10ft 16" 18" 20"CS - P F Stair System: 2012 IRC R106, R302.7, 311.7.2, R311.7.5, R311.7.8 Eq. Stair Risers 7 3/4" Max. height Eq. Stair Treads 10" Min. depth over (3) 11.5" MIN. Stair Stringers securely mounted to framing. with Cont. Handrail System mounted 36"above stair plane. with Handrail return to wall. with a Min. 6'-8" Head Clearance above stair plane. with all other Railing System to be min. 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 1 2" Gypsum Board under stairs H 2012 IRC, Section R106 and R308.4.5 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field 2012 IRC Code R106.1 with 1/2" Sheetrock Inside Occupancy separation between Vinyl Siding, Stucco and Faux Stone over Weather Resistive Barrier with (1) 2x6 Bottom Plate with (2) 2x6 Top Plates 2x6 Stud framed @ 24" O.C. UNO Exterior Walls: C Taped Prep'd for Interior Finishes between house, attic, and garage Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Max. Wall Height 8' 9' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 8' - 9 " 6' - 8 " 3' 35 ° 15' - 1 1 1 / 2 " H Scale: 1/4"=1'-0" H e a d r o o m H e i g h t H a n d r a i l H e i g h t 10 1/2" 7 3 / 8 " 8" 9' 1' - 2 " A4 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO A5 of 03-18-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M ST E V E N S HO M E S TOTAL SQ. FTG.= 4238 MAIN FLOOR=2141 BASEMENT =2097/1881 LIVING COLD STORAGE=50 GARAGE =1175 DE S I G N + BU I L D P. O . B o x 2 7 5 9 I d a h o F a l l s , I D 8 3 4 0 3 2 0 8 . 2 0 6 . 1 9 1 9 VA L L E Y V I E W 2 ww w . s t e v e n s h o m e s . c o m (2) #4 Horiz. w/in 12" of top of Concrete 8 12 Pitch Main 10 12 Pitch Front Gables and Sides (2) #4 Rebar Horiz. Cont. 5" Dining Room B CD E FG 2' - 1 0 " 8' - 9 1 / 2 " 1' - 0 1 / 2 " 9' (2) #4 Rebar Horiz. Cont. (2) #4 Rebar Horiz. Cont. 8" 12 8 A Family Area (2) #4 Rebar Horiz. Cont. Storage Family Area 13 ' - 1 1 1 / 2 " 13 ' - 1 1 1 / 2 " 19 ' - 2 " 36 ' - 3 " 2' - 6 " 5" 12 4 10 ' Plot Plan Scale: 1/8" =1'-0" D Size Paper Valley View Subdivision Block No. 8, Lot No. 4 City of Rexburg, Madison County Idaho Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Scale: 1/16"=1'-0" B Size Paper A5 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO A5 of 03-18-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M ST E V E N S HO M E S TOTAL SQ. FTG.= 4238 MAIN FLOOR=2141 BASEMENT =2097/1881 LIVING COLD STORAGE=50 GARAGE =1175 DE S I G N + BU I L D P. O . B o x 2 7 5 9 I d a h o F a l l s , I D 8 3 4 0 3 2 0 8 . 2 0 6 . 1 9 1 9 VA L L E Y V I E W 2 ww w . s t e v e n s h o m e s . c o m N O R T H Frankli n D r i v e R=236' L=77.21' 1 3 5 . 0 7 ' N 7 7 ˚ 3 0 ' 2 8 " E 101.69' N 1 2 ˚ 0 9 ' 3 2 " E 10.42' N44˚45'26"E 13 5 . 0 7 ' N 7 7 ˚ 3 0 ' 2 8 " E 72.17' S 1 2 ˚ 0 9 ' 3 2 " W 63 ' - 6 " 73'-6" 32 ' 10' 30 ' 10' Lin e s o f S e t b a c k 3 8 ' - 7 3 / 4 " 56'-4 7/16" 21'-8" Lines of S e t b a c k L i n e s o f S e t b a c k 21'-8" Location of New Construction 97'-1 9 / 1 6 " 9 7 ' - 1 9 / 1 6 " 39 ' - 7 5 / 8 " 63 ' - 6 " 14' 17' 13' 8'-6" 10' 11' 24 ' - 4 " 36'-6" 12 ' - 8 " 26 ' - 2 " 24 ' - 8 " 24' 13' 41 ' - 2 " 22 ' - 4 1 / 1 6 "