Loading...
HomeMy WebLinkAboutINSPECTION TICKET - 18-00468 - 50 Mill Race Rd - Attached DeckInspection Ticket Residential Framing/Structure Inspection on 09/26/2018: PASS Permit Number: 18-00468Permit Details Residential Accessory Use Permit Issued Date: 09/04/2018 Final Inspections Required Residential Building Final 50 Mill Race Rd 50 Mill Race Rd - Attached Deck Inspection Details larry.beesley@rexburg.org Inspected By: Larry Beesley Residential Framing/Structure Inspection on 09/26/2018: PASS D ESCRIPTIO N CO M M EN TS STATUS Floor joists are sized and spaced as per plans.COMPLETED Floor joists are free from major defects such as checks, large knots, cracks, and cuts. COMPLETED Floor joists are blocked as per plans (including 'squash blocks' for additional loads). COMPLETED Stairs are correct width and constructed properly (max 7 3/4" rise and min 11" tread). COMPLETED Beams, girders, and headers are properly sized with proper bearing. COMPLETED All wooden framing is nailed as per code.Your lag bolts in the ledger board should be 1/2" lags staggered every 12". Please go back through and put some 1/2" lags in along with the ones that you have already installed. COMPLETED Inspector Comments The framing looks good. The only concern that I have is the size of lag screws you put in the ledger board. I would recommend that you add some 1/2" lags along with the 5/16" ones that you have already installed. Thanks, Larry