HomeMy WebLinkAboutREVIEW PW 7/16/2018 - 18-00034 - 1160 Bond Ave - Dish One Satellite - New BuildingReview
Report
Current Public Works Review - Site Plan Status: REVISIONS
Application Number: 18-00034Permit Details
Application Received Date: 01/22/2018
Building - Commercial
Application Approved Date:
Application Approved Status: ACCEPTED
01/22/2018
1152 Bond Ave
Dish One Satellite - New Building
Status of Plan Reviews Completed
01/23/2018Plumbing Review REVISIONS
01/23/2018HVAC Review COMPLETED
01/24/2018Electrical Review COMPLETED
01/25/2018Public Works Review - Site Plan REVISIONS
02/22/2018Building Review APPW/COND
02/22/2018Planning and Zoning Review - Site Plan COMPLETED
03/07/2018Plumbing Review COMPLETED
03/08/2018Fire Department Review - Site Plan REVISIONS
03/12/2018Public Works Review - Site Plan REVISIONS
06/12/2018Fire Department Review - Site Plan COMPLETED
07/02/2018Planning and Zoning Review - Site Plan REVISIONS
07/16/2018Public Works Review - Site Plan REVISIONS
Permit Review Status
Plan Reviews Still in Progress
Building Review
Planning and Zoning Review - Site Plan
Public Works Review - Site Plan
DESCRIPTION COMMENTS STA TUS
*Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed!
Checked for linked cases YES
Plans are approved for a footing/foundation
ONLY permit?
YES
Miscellaneous Review REVISIONSPlans between trades do not match.
*Revisions Response :
Street : Sidewalk setback/continuos REVISIONSNo sidewalks on plans. 5 ft sidewalk required
along all right of way.
Sidewalk on North side of building to be 6 ft or
have wheel stops.
*Revisions Response :
Site Lighting : Photometric layout N/ANo lighting on plans.
Sewer: Connection to mainline N/AUsing existing utility stubs.
Reviewed By: Joel Gray
Review Date: 07/16/2018
Plan Review Details
joel.gray@rexburg.org
Public Works Review - Site Plan Status: REVISIONS
Page 1 of 2
Approval of plans does not constitue approval of variance from code
Public Works Review - Site Plan (Continued)
D ESCRIPTIO N CO MMEN TS STATUS
Water : Connection to main line N/AUsing existing utility stub. Stub on East side is
likely a 1" line only.
Hot tap to be done not a tee inserted on water
line on West side for fire hydrant.
Miscellaneous Review N/AUtility Easement problem needs to be
addressed.
Miscellaneous N/ASeveral storm retention notes need to be
reviewed for clarity.
Perimeter grading to allow no runoff onto
adjacent parcels.
No utility boxes in right of way?N/A
Dumpsters: 1 per 20 Units (non-dorm) or 1 per
50 beds (Dorm)?
COMPLETED
Storm : Drainage calcs COMPLETED
Storm : On-site retention COMPLETED
Parking Lot : Drainage COMPLETED
Parking Lot: Accessibility/layout Parking lot layout does not meet requirements
of Development Code Chapter 5.
How are deliveries made?
COMPLETED
Street : Entrance placement COMPLETED
Page 2 of 2
Approval of plans does not constitue approval of variance from code