HomeMy WebLinkAboutPLANS - 17-00662 - 902 Oak Hill Way - New SFRElevations Scale: 1/4" & 1/8" =1'-0" on 36" x 24" Paper Scale: 1/8" & 1/16"=1'-0" on 17" x 11" Paper Front Elevation Back Elevation Right ElevationLeft Elevation A1 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Fu l l e r R e s i d e n c e 90 2 O a k H i l l W a y A5 of 03-21-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO 7:12 Pitch-Main 8:12 Pitch Front and Sides 9' & 10' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP TOTAL SQ. FTG.= 4542 MAIN FLOOR=2268 BASEMENT =2274 GARAGE =1158 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 04-27-17 09-25-17 8 12 12 8 12 7 CRICKET Faux Stone Stucco Horizontal Siding 12 7 Foundation Plan Scale: 1/4"=1'-0" D Size Paper Scale: 1/8"=1'-0" B Size Paper Ventilation R408.1 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1 2" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & ROUND plate Washer 2 1/2 Ø x1 4" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2012 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2012 IRC Section R106.1 over Undisturbed Soil Window Well System: 2012 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. J Ventilation R408.1 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. A2A2 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Fu l l e r R e s i d e n c e 90 2 O a k H i l l W a y A5 of 03-21-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO Smoke Alarms 2012 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2012 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM 9' & 10' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP TOTAL SQ. FTG.= 4542 MAIN FLOOR=2268 BASEMENT =2274 GARAGE =1158 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M T-Wall 04-27-17 Fl o o r T r u s s D i r e c t i o n TRIPLE CAR GARAGE 4" CONCRETE SLAB SLOPE CONC. FLOOR TO DRAIN TO GARAGE DOOR HOLDDOWN: H1 SIMPSON STRONG TIE STHD8-INSTALLED & NAILED AS PER MANUFACTURERS RECOMMENDATIONS CONCRETE TO WOOD CONNECTION H1 4 14 3 2 1 26 6 8 Storage Theater Room Exercise Room Bedroom 3 Bedroom 4 Family Room Game Area H1 H1 H1 9' Basement F. Walls up to main 3 0 6 8 Beam3060 Temp 26 6 8 3068 W e t B a r Walk-Out Portion 84' 4040 SV 4040 SV 3060 Temp 4 0 5 0 S V 40 5 0 26 6 8 4'14'4' 16' 14'27' 63'17'4' 2'-6"4'-6"2'-6"4'-6" 13 ' - 7 " 14 ' 13 ' - 2 " 5' 9' 7' - 3 " 5' - 1 1 " 42 ' - 2 " 8'-8"8'13' 11' 2' 2' 42' 12'-4" 12'12'-6" 24'-6" 11 ' - 2 " 7'7' 14' 31 ' 3' - 2 " 4' 20 ' 5' 2' 60 ' - 2 " 9'-6"7'-6" Cu t f o r 6 ' D o o r Op e n i n g w i t h Re q u i r e d B l o c k i n g Retaining Wal S S S 2' - 1 0 " 6' 10 CFM Fresh Air 10 CFM Fresh Air 10 CFM Fresh Air 10 CFM Fresh Air 10 CFM Fresh Air WH WH seimic straps Furnance 8' - 3 " 5 ' - 8 " 5'- 8 " 34'-4" H1 H1 3'-1 0 " 1 0 ' - 8 1 / 2 " 8' - 1 0 1 / 2 " 6' - 2 " 2' 27 ' 7'-2"13'-10" 22 ' - 2 " H1 H1 H1 H1H1 H1 H1 H1 11'-8"11'11'-8" 4x4 Post over 16x16x8 Footer (4)TYP H1 H1H1 J Da y l i g h t 2668 3' - 2 " 2' - 1 0 " 10 ' - 1 1 " 6' - 6 " 7' - 7 " Cut for 18' Garage Opening with Required Blocking 11 ' Cu t f o r 1 0 ' G a r a g e O p e n i n g wi t h R e q u i r e d B l o c k i n g 4'-10" 4050 40 5 0 4050 3'3'-2" 1'-4" 11 ' - 3 " 1' J Daylight UP CM LN 3' Clearance in front of Furnance Seismic Straps around WH Mechanical 24 6 8 2668 24 6 8 2468 2- 2 6 6 8 S CM Bath 50 CFM 12'-6" 14'-7" Bath 50 CFM 6" S t e p Do w n 7' Under Stair Access 4' - 4 " 3'-6" 3' - 3 " 8'-7" 3' - 3 " 24 6 8 P Built-in Bunks Built-in Bunks 30 6 8 24 6 8 24 6 8 WS 2- 2 6 6 8 Beam 09-25-17 2668 Trunk Line 3' - 4 " 2x 6 W a l l C e n t e r o f F o o t i n g 5' - 8 " 5'-5" 3' - 1 0 " Trunk Line 5' 6' - 1 1 " 2x 6 W a l l 6' - 0 " 2 x 6 W o o d F r a m e W a l l ov e r 3 ' - 0 " C o n c . F D N W a l l Fl o o r T r u s s D i r e c t i o n Step Down Concrete Step Down Concrete 2'- 1 0 " 2'- 1 0 " 6' 2' - 1 0 " 40 5 0 2' - 1 0 " 5' - 1 0 " 3' - 1 " 11'-6" 2' - 1 " 2' - 1 0 " 3' C e n t e r o f F o o t i n g 15 ' 3' - 1 0 " 1'-10" 4' - 8 " 1' - 5 " 3' - 5 " 4' - 9 " 5' - 1 0 " 10'-1"3'-2"16'-8" 3' - 5 " 4'-10" 3'-8"4'-9" 5' 2' - 1 0 " 31'-2" 8'-10" 14'-7" Beam 4' Center of Beam 10 ' - 9 " Center of Footing Center of Footing 2' - 6 " Center of Footing 10 ' - 4 " 8' - 5 " Day Light Basement earth backfill @ 2'-6" 2' - 1 1 / 2 " 3'3' Foundation Wall with 6' 4' 6' - 8 " Bedroom AA Section A-A Scale: 1/8"=1'-0" B Size Paper 9' 8' - 9 1 / 2 " 8" Scale: 1/4"=1'-0" D Size Paper H1H1 H1 3' - 9 " 2" R o c k Le d g e 2" R o c k Le d g e 2" R o c k Le d g e 2" R o c k Le d g e 2" R o c k Le d g e 2" R o c k Le d g e 4' - 7 " 1'-10 1/2" 5'-6" 5' 8'-7" 4'- 2 " 3'- 6 1 / 2 " 4'-2" Duct Chase H1 H1 3' 6' - 1 1 / 2 " 2' 7' - 1 1 / 2 " A-A B-B D-D D Stepping Concrete 6" Lower than FF Stepping Concrete 12" Lower than FF H1 Foo t e r 1' 8' - 1 1 / 2 " C-C BB C C 6" S t e p Do w n 16 ' - 3 " D H1H1 16x1 6 x 8 H1 18 ' - 1 0 " Foote r 24 x 2 4 x 8 Main Floor Scale: 1/4"=1'-0" D Size Paper Scale: 1/8"=1'-0" B Size Paper Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2012 IRC, Section R106 and R311.6 Saftey Glazing 2012 IRC, Sections R106 and R308.4.5 Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Furnace: Location of furnace and water heater 2012 IRC, Section R106, and M1305 Elevate all sources of ignition in the garage a min. of 18" above the floor 2012 IRC, Sections R106, and M1307.3 Provide a protection post in the garage to prevent vehicle damage to furnace and water heater. 2012 IRC, Section R106, M1307.3.1 Crawl Space: Through Floor min 18"x24" or through perimeter wall min 16"x24" required crawl space opening. If applicable, refer to mechanical code for access requirements where mechanical equipment is located under floors. 2012 IRC, Section R106, R408.4 M1305.1.4 Smoke Alarms 2012 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2012 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM 4' Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 4' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r IBWP 3 Interior Braced Wall Panel IBWP 2012 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSB Nailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 5 1/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2012 IRC, Section R106 and R311.6 Saftey Glazing 2012 IRC, Sections R106 and R308.4.5 A3 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Fu l l e r R e s i d e n c e 90 2 O a k H i l l W a y A5 of 03-21-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO 9' & 10' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP TOTAL SQ. FTG.= 4542 MAIN FLOOR=2268 BASEMENT =2274 GARAGE =1158 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 04-27-17 32 ' 3'-6 " 40 4 0 T LN Bench 31 ' 5' 22 ' 2' 2'10'2' 24'-6" 13'8'12'-4"8'-8" 3050 12'-6"12' 5050 5060 2' 6' Family RoomDining Kitchen Utility Mudd Bedroom 2 Sitting Room Master Bedroom M. Bath WIC Entry Office 3060 SH 3060 SH 5050 50603060 3060 3068 30 6 8 24 6 8 30 6 8 2668 26 6 8 2 6 6 8 Linen Bath 26 6 8 26 6 8 2468 3068 w 18" SLS 3068 17' 4'14'4'14' 4' 15 ' 14 ' 13 ' 2' 4' 2' - 6 " 8' - 4 " 15 ' 9'4' 4' 27' 4' - 6 " 10 ' 4' 2' - 1 0 " 84' 12 DW V a u l t 10' Flat Ceiling 10' Box Ceiling Box Tray Ceiling 10' Flat Ceiling Lockers 4'-6"4'-2"5'-5"6'-11" 1'-6"8'1'-6" 4'4'6'-6"6'-6" 3' - 4 " 2' - 8 " 9' Flat Ceiling 9' Wall 10' x 8' OH Garage Door S S S S 4050 2'-8"4'-6"4'-6"2'-4" 11 ' - 1 " 2' - 1 1 " 6'6'6'-3"6'-3" 14' 6'-6"6'4'-2"4'-6"4'-6"9'-6"4'-4" 42 ' 63' 6' - 2 " 41'-6" 10 CFM Fresh Air 10 CFM Fresh Air 10 CFM Fresh Air 10 CFM Fresh Air 10 CFM Fresh Air 50 CFM 80 WHF 50 CFM 50 CFM 100 CFM 2' 4' - 6 " 1' - 6 " 2' 7'-2" 2' 13'-10" Covered Deck 20 ' 8' - 4 " 15 ' 3010 1/4 Rnd 6010 1/4 Rnd 5010 1/4 Rnd BWP BWPBWP BWPBWP BWP BWPBWP BWP BWP BWP BWP V a u l t 10'-8" x 14'-8"19'-4"x 14'-6" OC G a s F P 4' - 8 " 3' - 6 " 8' - 9 1 / 2 " 7'-8" x 10' 12' x 11'-10" 13 1'-4" 1 1 ' - 1 0 " 2'-4 " 4'-1 0 " 2'- 1 1 1 / 2 " 5'-11 1/2"4'-10" 17' x 14'-8" 9' Flat Ceiling 4'-2"5'-4"6'2'-4" 7' 1' - 6 1 / 2 " 4' - 6 " 6 ' - 4 " 3' - 4 1 / 2 " 4' - 9 " 7' - 2 " 2' - 1 0 " 5'- 7 1 / 2 " 9' - 6 " 3' - 1 0 " 11 ' 9' 12' x 11'-7" 6'- 7 " 5'-10" 2'- 1 0 " 12'- x 12' 9' Flat Ceiling 9' Flat Ceiling 9' Flat Ceiling 4' 6' 3'-2" Pantry WIC 60 ' 5' 5' 23'-10" 23 ' - 8 " 4' 4 ' 11 " M i n . 11" Min. 6'x6' Rollup Door Lo c k e r s 4068 Slider DO 305 0 S H 5050 2 8 6 8 9'-2 1/2"8'-3 1/2" WIS 5'- 8 " 2' Plant Shelf Plant Shelf 9' Cap Plate 11'-10" 301030103010301050105010 4'-6" 2'- 1 0 " 5'-10" 5' - 8 " 2' - 1 0 " 2' - 1 0 " 1 0 ' 3 Car Garage 1158 Square Feet Contractor to locate exact location of req'd 22" x 30" Attic Access Point Min. 30" Vert. Head Room Clearance (2009-R807.1) 20min Fire Rated 1-3/8" Solid Door or Equal DN CM Deck Covered Porch 5050 SV Recess in Wall Size DBT 18 x 8 O H G a r a g e D o o r 8' - 5 " 5050 SV 30 3 0 5050 SV 6" 09-25-17 9' Flat Ceiling 9' Flat Ceiling 18 ' 15 ' - 6 " 15 ' - 6 " 8'-2" 1' - 1 0 " 3'-7" 2 ' 3' - 7 " 3'- 2 " 2' - 1 1 " 1'-2" 3' - 7 " 2' 3' - 7 " 2' - 6 " 6' - 2 " 8'-6" 9' 34'-4"13'-4"15'-4" 11'-10"2'-2" 2' 2'- 6 " 3'- 1 0 " 3'-8 1 / 2 " 3'-9 1/2" 10 ' - 5 1 / 2 " 3'-4 1/2" IBWP 5 (4' B.S.) 2' - 6 " 1hr Firewall No Penetrations 4' - 1 " 6' - 9 " 3 " 10 ' - 5 1 / 2 " 3' - 2 " Duct 3' 10 " H2 IB W P 5 ( 4 ' B . S . ) 2x6 Wall 2x6 Wall H2 2x6 Wall 3' HOLDDOWN: H2 SIMPSON STRONG TIE STHD8-INSTALLED & NAILED AS PER MANUFACTURERS RECOMMENDATIONS WOOD TO WOOD CONNECTION Chase H2 H2 H2 H2H2 H2 H2 5' - 8 " 2' - 1 0 " 8' - 5 " 2'-4" 4'-6"1'-6" Se e G a r a g e P o r t a l D e s i g n ( p a g e A 5 ) See Garage Portal Design (page A5) BW P BW P BWP Cross Section Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e Decking System: (if applicable) 2012 IRC, Section R106.1, R311.5, R502.3.1(1), R502.3.1 (2),R507, R703.8 Req. handrail at ext. steps over 2x4 floor decking with Required Spacing over 2x8 Deck Joist Stingers connected to house 2x10 rim-board with angle bolt 2 bolts need to be in top 4 12" of Ledger board over 2x10 ledger boards connected by Simpson Joist Hanger anchor over 8Ø x 24" deep conc. pier over 8x16x16 conc. footing with req. horizontal and vertical rebar over undisturbed soil. K Taped and Prep'd for Interior Finishes over 1/2" Sheetrock on Ceiling Side Foundation Wall System: Min. (2) Anchor Bolts per Sill Plate w/nut & Max. 12" from all Corners or Splices with 1/2" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded ROUND Plate Washer 2 1/2Ø x1/4" Min. for ea. Bolt over Concrete Foundation Wall Consistant w/2012 IRC R401-403 with Asphalt Emulsion on Exterior Side Consistant w/2012 IRC Section R106.1 over Continuous Concrete Footings connected to Rim Joist, spliced using gal. metal ties over Undisturbed Soil 2x6 Treated Sill Plate over Foam Sill Sealer fastened w/6 16d nails ea. side not less than .058" x 1.5" wide G 2012 IRC, Section R106 and R308.4.5 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field Taped Prep'd for Interior Finishes Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) over 11-7/8 TJI Engineered Floor Joist 3/4" T&G OSB Sub-floor Glued & Nailed 2012 IRC Code R106.1 2x4 Stud framed @ 24" O.C. Floor System: 2012 IRC Code with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides with min. R-21 Batt Insulation 2012 IRC Code Interior Walls: with 1/2" Sheetrock Inside Occupancy separation between with (1) 2x6 Bottom Plate with (2) 2x6 Top Plates 2x6 Stud framed @ 24" O.C. UNO 2x6 Fascia Board with 3" Continuous Soffit Venting with add'l 2x4 Support as Required Exterior Walls: with 3/8" Soffit Sheeting with style "D" Metal Drip Edge 2012 IRC Code Soffit System: A C E D B Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 15 23 12 12 17 12 12 16 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Smoke Alarms 2012 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms S Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Carbon Monoxide Alarms 2012 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fastners for Preservative treated wood Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasterners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the front line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Ventilation 2012 IRC, Section R408.1, R408.2, and R408.3 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 300 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Taped Prep'd for Interior Finishes CM between house, attic, and garage Window Well System: 2012 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. J with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes Basement Furring: with 6-Mill Poly Vapor Barrier with (2) 2x4 Top Plates 2x4 Stud Framed @ 24" O.C. with Baring Walls @ 16" O.C. with R-13 Batt Insulation with (1) 2x4 Bottom Plate F 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Max. Wall Height 8' 9' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 Cross Section Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper Fasten sheathing to header w 8d common or gal. box nails in 3" grid pattern as shown Header to jack-stud strap per table R602.10.6.4 on both sides of opening opposite side of sheathing Min. Length of panel per Table R602.10.5 Min. double 2x4 framing covered w min. 716" thick wood structual panel sheathing w 8d common or gal. box nails at 3" o.c. in framing (studs and sills) as shown. typ. Min. (2) 4200 LB Tie-Down Device (Embedded into Concrete and Nailed into Framing) (1) 5 8" Ø Anchor Bolts R403.1.6 with 2"x2"x316" plate washer Min. Double 2x4 Post Typical Portal Frame Construction If needed, panel splice edges shall occur over & be nailed to common blocking w/in middle 24" of wall mid-height. One row of 3" o.c. nailing is req. in ea. panel edgeMin. 1000LB Tie down Device Extent of Header Single Portal Frame (One Braced Wall Panel) Extent of Header Double Portal Frame (Two Braced Wall Panels) Ma x H e i g h t 1 0 ' - 0 " MIN. WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS Table R602.10.6.1 Seismic Design Category and Windspeed Tie-Down Force (lb.) 8 ft. 2'-4" 9 ft. 2'-8" 10 ft. 2'-8" 11 ft. 3'-2" 12 ft. 3'-6" SDC A,B, and C Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 1800 3000 2000 3300 2200 3600 SDC D,D, and D Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 1800 3000 - - 012 2'-8"2'-8"2'-8"Note aNote a - - Height of Braced Wall Panel Sheathed Width Sheathed Width Alternate Braced Wall Panel Garage Portal Design Figure R602.10.6.4 11" Min Run on Conc. Step into house Max Rise 7 3/4" Concrete Steps into House Decking System: (if applicable) 2012 IRC, Section R106.1, R311.5, R502.3.1(1), R502.3.1 (2),R507, R703.8 Req. handrail at ext. steps over 2x4 floor decking with Required Spacing over 2x8 Deck Joist Stingers connected to house 2x10 rim-board with angle bolt 2 bolts need to be in top 4 12" of Ledger board over 2x10 ledger boards connected by Simpson Joist Hanger anchor over 8Ø x 24" deep conc. pier over 8x16x16 conc. footing with req. horizontal and vertical rebar over undisturbed soil. K Taped and Prep'd for Interior Finishes over 1/2" Sheetrock on Ceiling Side Foundation Wall System: Min. (2) Anchor Bolts per Sill Plate w/nut & Max. 12" from all Corners or Splices with 1/2" Anchor Bolts @ 72" O.C. 10" Long over Concrete Foundation Wall Consistant w/2012 IRC R401-403 with Asphalt Emulsion on Exterior Side Consistant w/2012 IRC Section R106.1 over Continuous Concrete Footings connected to Rim Joist, spliced using gal. metal ties over Undisturbed Soil 2x6 Treated Sill Plate over Foam Sill Sealer fastened w/6 16d nails ea. side not less than .058" x 1.5" wide G Roof System: 2012 IRC Code Architectural Grade, 25 year Asphalt Shingles over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 7 & 8:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2012 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall Taped Prep'd for Interior Finishes Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) over 11-7/8 TJI Engineered Floor Joist 3/4" T&G OSB Sub-floor Glued & Nailed 2x4 Stud framed @ 24" O.C. Floor System: 2012 IRC Code with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides 2012 IRC Code Interior Walls: 2x6 Fascia Board with 3" Continuous Soffit Venting with add'l 2x4 Support as Required with 3/8" Soffit Sheeting with style "D" Metal Drip Edge 2012 IRC Code Soffit System: A E D B Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 12 16 12 12 12 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Smoke Alarms 2012 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms S Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Carbon Monoxide Alarms 2012 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fastners for Preservative treated wood Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasterners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the front line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Ventilation 2012 IRC, Section R408.1, R408.2, and R408.3 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 300 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. CM with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes Basement Furring: with 6-Mill Poly Vapor Barrier with (2) 2x4 Top Plates 2x4 Stud Framed @ 24" O.C. with Baring Walls @ 16" O.C. with R-13 Batt Insulation with (1) 2x4 Bottom Plate F Min. 3"x11 14" net header (Steel header prohibited) Ma x T o t a l W a l l H e i g h t 1 2 ' - 0 " Min. reinforcing of foundation, (1) #4 bar top & bottom of footing. Lap bars 15" min. Min. Footing under opening is 12"x12" 2'-18" finished width for single or double portal Stair System: 2012 IRC R106, R302.7, 311.7.2, R311.7.5, R311.7.8 Eq. Stair Risers 7 3/4" Max. height Eq. Stair Treads 10" Min. depth over (3) 11.5" MIN. Stair Stringers securely mounted to framing. with Cont. Handrail System mounted 36"above stair plane. with Handrail return to wall. with a Min. 6'-8" Head Clearance above stair plane. with all other Railing System to be min. 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 12" Gypsum Board under stairs H 2012 IRC, Section R106 and R308.4.5 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field 2012 IRC Code R106.1 with 1/2" Sheetrock Inside Occupancy separation between Stucco, Vinyl Siding and Faux Stone over Weather Resistive Barrier with (1) 2x6 Bottom Plate with (2) 2x6 Top Plates 2x6 Stud framed @ 24" O.C. UNO Exterior Walls: C Taped Prep'd for Interior Finishes between house, attic, and garage Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Max. Wall Height 8' 9' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 8' - 9 " 6' - 8 " 3' 35 ° 1 5 ' - 1 1 1 / 2 " H Scale: 1/4"=1'-0" H e a d r o o m H e i g h t H a n d r a i l H e i g h t 10 1/2" 7 3 / 8 " 8" 9' 1' - 2 " A4 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Fu l l e r R e s i d e n c e 90 2 O a k H i l l W a y A5 of 03-21-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO TOTAL SQ. FTG.= 4542 MAIN FLOOR=2268 BASEMENT =2274 GARAGE =1158 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 04-27-17 09-25-17 3' Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 3' 8'x8' Shear Panel on Single Side 48.5" to c n t r IBWP 3 Interior Braced Wall Panel IBWP 2012 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSB Nailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 5 1/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. (2) #4 Rebar Horiz. Cont. Master Bedroom Bathroom Bedroom 2 D BathWICBedroom 8" 9' 1' - 2 " 9' 12 ' - 1 1 / 2 " 31 ' - 1 1 1 / 2 " 31 ' - 3 1 / 2 " 23 ' - 3 1 / 2 " 22 ' - 3 1 / 2 " Storage Hall B C E F G J (2) #4 Rebar Horiz. Cont. (2) #4 Rebar Horiz. Cont. (2) #4 Rebar Horiz. Cont. Wa l k - o u t 7 12 AA 3' 6' - 1 1 / 2 " 2' 7' - 1 1 / 2 " A-A B-B 1' 8' - 1 1 / 2 " C-C D-D Stepping Down Conc. (See A2 for Location) 13 ' - 6 1 / 2 " 3.5 12Family R o o m V a u l t i n f o r e g r o u n d Plot Plan Scale: 1/8" =1'-0" D Size Paper Scale: 1/16"=1'-0" B Size Paper Pine Brook Estates Div. 2, Block 5, Lot 4 902 Oak Hill Way City of Rexburg Madison County, ID NORTH A5 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Fu l l e r R e s i d e n c e 90 2 O a k H i l l W a y A5 of 03-21-17 Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 1 7 Copyright Sundance Drafting and Design 2017 Copyright Sundance Drafting and Design 2017 1/8"=1'-0" UNO TOTAL SQ. FTG.= 4542 MAIN FLOOR=2268 BASEMENT =2274 GARAGE =1158 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 04-27-17 10.24' S00˚00'21"W Lines of Setback 60 ' 4' 15 ' 14'4' 13 ' 32'-5" 45 ' 55' - 1 1 " 55 ' - 7 " 15 1 . 4 5 ' S 0 ˚ 0 0 ' 2 1 " W 14 0 . 7 5 ' S 0 0 ˚ 1 4 ' 5 8 " E Oak Hill Way 64' S89˚54'46"E 11' Li n e s o f S e t b a c k 22' 35 ' - 1 1 1 / 2 " 5 5 ' - 9 " 10'-10" 27' 14 ' 31 ' 7'-6" 85.48' S89˚36'39"E 7'-6" 150.1' N89˚59'39"W 25 ' Li n e s o f S e t b a c k 5' 84' 12'-6"8'-8" 17' 12'11' 18 ' 14' 24 ' 46 ' - 5 " 45 ' Location of New Construction Deck Lines of Setback 09-25-1730' 1 0 3 ' - 3 " 33'-4" 5 7 ' - 2 1 / 2 " 103 ' - 3 " 32'-3" 30' 5 ' - 8 " 6' 14' 6' 5'- 8 " 2' 6' 2' 6' 7'-2" 2' 13'-10" 2' 22 ' 20 ' 68 ' - 8 " 6 8 ' - 7 1 / 2 " 44 ' - 1 1 1 / 2 " 60 ' 46 ' - 6 " 32 ' 33'-3"