LOAD SHORT FORM - 18-00496 - 876 Larch Dr - New SFR
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:31 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 1 ...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Load Short Form 9/1/18Date:AH1 Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) Semi-tightConstruction quality7570Inside db (°F) 0Fireplaces1476Design TD (°F) H-Daily range 5050Inside humidity (%) -3162Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model ML195UH070XP36B-*Cond 14ACX-030-230A** AHRI ref 4805339 Coil C(R,S,T)30B34+SLP98UH090XV48C*+TDR AHRI ref 9851131 Efficiency 95 AFUE Efficiency 12.4 EER, 16 SEER Heating input Btuh66000 Sensible cooling Btuh18200 Heating output Btuh64000 Latent cooling Btuh7800 Temperature rise °F80 Total cooling Btuh26000 Actual air flow cfm867 Actual air flow cfm867 Air flow factor cfm/Btuh0.026 Air flow factor cfm/Btuh0.111 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room2 36 467 45 12 5 Room4 306 3768 1250 97 139 Room5 162 1256 594 32 66 Room6 192 2953 980 76 109 Room7 84 695 123 18 14 Room8 60 610 112 16 12 Room9 168 3029 603 78 67 Room10 207 2397 577 62 64 Room11 439 4054 829 105 92 Room1 1106 14346 2673 370 298 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:31 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 2 ...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N AH1 d 2760 33574 7787 867 867 Other equip loads 0 0 Equip. @ 0.94 RSM 7319 Latent cooling 0 TOTALS 2760 33574 7319 867 867 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:31 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 3 ...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Load Short Form 9/1/18Date:basement AH Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) Semi-tightConstruction quality7570Inside db (°F) 0Fireplaces1476Design TD (°F) H-Daily range 5050Inside humidity (%) -3162Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Goodman Mfg. Trade LENNOX Trade GOODMAN; JANITROL; AMANA DISTI... Model ML195UH045XP36B-*Cond GSX160181F AHRI ref 4805338 Coil CAPT3131C4A AHRI ref 7365915 Efficiency 95 AFUE Efficiency 12.5 EER, 15 SEER Heating input Btuh44000 Sensible cooling Btuh11900 Heating output Btuh42000 Latent cooling Btuh5100 Temperature rise °F80 Total cooling Btuh17000 Actual air flow cfm567 Actual air flow cfm567 Air flow factor cfm/Btuh0.059 Air flow factor cfm/Btuh0.357 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room17 215 1963 411 115 147 Room15 631 4201 1050 247 375 Room13 96 1078 48 63 17 Room12 247 2418 78 142 28 basement AH d 1189 9660 1588 567 567 Other equip loads 0 0 Equip. @ 0.94 RSM 1493 Latent cooling 0 TOTALS 1189 9660 1493 567 567 2018-Sep-01 09:11:31 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 1...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Building Analysis 9/1/18Date:AH1 Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor:7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation:5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F)SimplifiedMethod)H(34-Daily range (°F) Semi-tightConstruction quality60-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing DoorsCeilings Floors Infiltration % of loadBtuhBtuh/ft²Component 39.5132544.9Walls 14.5485824.3Glazing 2.894411.4Doors 7.324591.5Ceilings 3.210902.12.1Floors 32.7109703.7Infiltration 00Ducts00Piping00Humidification00Ventilation0Adjustments100.033574Total Cooling Walls Glazing Doors Ceilings Floors Infiltration % of loadBtuhBtuh/ft²Component 16.312730.5Walls 47.4368718.5Glazing 3.02302.8Doors 17.513590.8Ceilings 2.21740.3Floors 13.710640.4Infiltration 00Ducts00Ventilation00Internal gains 00Blower0Adjustments100.07787Total Latent Cooling Load = 0 BtuhOverall U-value = 0.059 Btuh/ft²-°F Data entries checked. 2018-Sep-01 09:11:31 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 2...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Building Analysis 9/1/18Date:basement AH Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor:7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation:5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F)SimplifiedMethod)H(34-Daily range (°F) Semi-tightConstruction quality60-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Floors Infiltration % of loadBtuhBtuh/ft²Component 51.349533.8Walls 12.1116724.3Glazing 000Doors1.61521.5Ceilings 20.619871.71.7Floors 14.514013.7Infiltration 00Ducts00Piping00Humidification00Ventilation0Adjustments100.09660Total Cooling Walls Glazing Ceilings Infiltration % of loadBtuhBtuh/ft²Component 3.7590.0Walls 82.4130927.3Glazing 000Doors5.3840.8Ceilings 000Floors8.61360.4Infiltration 00Ducts00Ventilation00Internal gains 00Blower0Adjustments100.01588Total Latent Cooling Load = 0 BtuhOverall U-value = 0.038 Btuh/ft²-°F WARNING: window to floor area ratio = 4.0% - less than 5%. 2018-Sep-01 09:11:31Right-Suite® Universal 2018 18.0.19 RSU20477 Page 1...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Component Constructions 9/1/18Date:basement AH Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F) SimplifiedMethod)H(34-Daily range (°F) Semi-tightConstruction quality60-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B19-0wc-6: Bg wall, heavy dry or light damp soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh 140.0510653.8219.00.043279n 170.0513403.8219.00.043351e 130.0412923.6919.00.043351s 150.0412563.7519.00.043335w 590.0549533.7619.00.0431316all Partitions (none) Windows 61C: 61C; 6.67 ft head ht 60418.977824.300.32032s 55134.438924.300.32016w 115524.1116724.300.32048all Doors(none) Ceilings16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 840.841521.5250.00.020100 Floors 21A-28c: Bg floor, heavy dry or light damp soil, 6.5' depth, carpet flr fnsh 0019871.6700.0221189 2018-Sep-01 09:11:31Right-Suite® Universal 2018 18.0.19 RSU20477 Page 2...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Component Constructions 9/1/18Date:AH1 Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F) SimplifiedMethod)H(34-Daily range (°F) Semi-tightConstruction quality60-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 3230.4733594.9422.00.065680n 3320.4734574.9422.00.065700e 2860.4729814.9422.00.065603s 3320.4734574.9422.00.065700w 12730.47132544.9422.00.0652683all Partitions (none) Windows 61C: 61C; 6.67 ft head ht 92910.6214024.300.32088n 210918.9271824.300.320112s 303815.2485824.300.320200all Doorsmetal: Door, mtl pur core type 1172.7847911.410.50.15042n 1132.7846511.410.50.15041s 2302.7794411.410.50.15083all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 13590.8424591.5250.00.0201618 Floors 19A-30bscp: Part floor, carpet flr fnsh, r-30 ins, frm flr, 12" thkns, 5/8" gypsum board int fnsh 1740.409442.1730.00.034435 21A-24c: Bg floor, heavy dry or light damp soil, 6' depth, carpet flr fnsh 01451.9000.02577 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 1...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Project Summary 9/1/18Date:AH1 Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F70 Inside db °F75Design TD °F76 Design TD °F14Daily range HRelative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh33574 Structure Btuh7787DuctsBtuh0DuctsBtuh0Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0(none)(none)Humidification Btuh0 Blower Btuh0PipingBtuh0Equipment load Btuh33574 Use manufacturer's data nRate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh7319 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Semi-tight0Fireplaces Structure Btuh-1478Ducts Btuh0Central vent (0 cfm)Btuh0CoolingHeating(none)27602760Area (ft²)Equipment latent load Btuh02483924839Volume (ft³)Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh7319Equiv. AVF (cfm)82156 Req. total capacity at 0.70 SHR ton0.9 Heating Equipment Summary Cooling Equipment Summary Make Lennox Make LennoxTradeLENNOXTradeLENNOXModelML195UH070XP36B-*Cond 14ACX-030-230A**AHRI ref 4805339 Coil C(R,S,T)30B34+SLP98UH090XV48C*+TDRAHRI ref 9851131Efficiency95 AFUE Efficiency 12.4 EER, 16 SEERHeating input Btuh66000 Sensible cooling Btuh18200Heating output Btuh64000 Latent cooling Btuh7800Temperature rise °F80 Total cooling Btuh26000Actual air flow cfm867 Actual air flow cfm867Air flow factor cfm/Btuh0.026 Air flow factor cfm/Btuh0.111Static pressure in H2O0.70 Static pressure in H2O0.70Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 2...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Project Summary 9/1/18Date:basement AH Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F70 Inside db °F75Design TD °F76 Design TD °F14Daily range HRelative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh9660 Structure Btuh1588DuctsBtuh0DuctsBtuh0Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0(none)(none)Humidification Btuh0 Blower Btuh0PipingBtuh0Equipment load Btuh9660 Use manufacturer's data nRate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh1493 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Semi-tight0Fireplaces Structure Btuh-189Ducts Btuh0Central vent (0 cfm)Btuh0CoolingHeating(none)11891189Area (ft²)Equipment latent load Btuh029712971Volume (ft³)Air changes/hour 0.210.40 Equipment Total Load (Sen+Lat)Btuh1493Equiv. AVF (cfm)1020 Req. total capacity at 0.70 SHR ton0.2 Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Goodman Mfg.Trade LENNOX Trade GOODMAN; JANITROL; AMANA DISTI...Model ML195UH045XP36B-*Cond GSX160181FAHRI ref 4805338 Coil CAPT3131C4AAHRI ref 7365915Efficiency95 AFUE Efficiency 12.5 EER, 15 SEERHeating input Btuh44000 Sensible cooling Btuh11900Heating output Btuh42000 Latent cooling Btuh5100Temperature rise °F80 Total cooling Btuh17000Actual air flow cfm567 Actual air flow cfm567Air flow factor cfm/Btuh0.059 Air flow factor cfm/Btuh0.357Static pressure in H2O0.70 Static pressure in H2O0.70Space thermostat Load sensible heat ratio 1.00 2018-Sep-01 09:11:32 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 1 ...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:AED Assessment 9/1/18Date:AH1 Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F))H(34-Daily range (°F) 60-Wet bulb (°F)7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gla z i n g l o a d ( B t u h ) Hour of Day 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 45.4%. Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 649 Btuh (PFG - 1.3*AFG) 2018-Sep-01 09:11:32 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 2 ...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:AED Assessment 9/1/18Date:basement AH Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F))H(34-Daily range (°F) 60-Wet bulb (°F)7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gla z i n g l o a d ( B t u h ) Hour of Day 0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 41.4%. Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 154 Btuh (PFG - 1.3*AFG) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 1...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Right-J® Worksheet 9/1/18Date:AH1 Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name AH1 Room2 2 Exposed wall 329.5 ft 6.0 ft3Room height 9.0 dft 9.0 heat/coolft 4 Room dimensions ft6.0x6.0 5 Room area 2759.9 ft²36.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 810 680 3359 323 54 54 267 26.GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 88 0 2140 929 0 0 0 0 .DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 42 42 479 117 0 0 0 0 11 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 700 700 3457 332 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 756 603 2981 286 0 0 0 0GG61C61C0.3200.320 ss 24.3224.32 18.8818.88 112 0 2718 2109 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 41 41 465 113 0 0 0 0WW15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 700 700 3457 332 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 1618 1618 2459 1359 0 0 0 0 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 435 435 944 174 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 77 77 145 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 649 0 Envelope loss/gain 22604 6723 267 26 12 a)Infiltration 10970 1064 200 19 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)33574 7787 467 45 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal33574778746745 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 33574 7787 467 45 Air required (cfm)Air required (cfm)867 867 12 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 2...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Right-J® Worksheet 9/1/18Date:AH1 Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room4 Room5 2 Exposed wall 35.0 ft 9.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft18.0x17.0 ft18.0x9.0 5 Room area 306.0 ft²162.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0.GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 11 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 153 123 608 58 81 65 321 31GG61C61C0.3200.320 ss 24.3224.32 18.8818.88 30 0 730 566 16 0 389 302 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0WW15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 162 162 800 77 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 306 306 465 257 162 162 246 136 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 179 96 Envelope loss/gain 2603 1137 956 564 12 a)Infiltration 1165 113 300 29 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)3768 1250 1256 594 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal376812501256594 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 3768 1250 1256 594 Air required (cfm)Air required (cfm)97 139 32 66 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 3...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Right-J® Worksheet 9/1/18Date:AH1 Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room6 Room7 2 Exposed wall 28.0 ft 7.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft12.0x16.0 ft7.0x12.0 5 Room area 192.0 ft²84.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 0 0 0 0.GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 11 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 108 108 534 51 63 63 311 30 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 144 119 588 56 0 0 0 0GG61C61C0.3200.320 ss 24.3224.32 18.8818.88 25 0 608 472 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0WW15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 192 192 292 161 84 84 128 71 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 12 12 23 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 149 0 Envelope loss/gain 2021 890 462 100 12 a)Infiltration 932 90 233 23 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2953 980 695 123 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal2953980695123 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2953 980 695 123 Air required (cfm)Air required (cfm)76 109 18 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 4...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Right-J® Worksheet 9/1/18Date:AH1 Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room8 Room9 2 Exposed wall 5.0 ft 26.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.0x12.0 ft14.0x12.0 5 Room area 60.0 ft²168.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 0 0 0 0 108 88 435 42.GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 0 0 0 0 20 0 486 211 .DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 11 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 45 45 222 21 126 126 622 60 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0WW15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 0 0 0 0 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 60 60 91 50 168 168 255 141 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 60 60 130 24 168 168 364 67 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 -1 Envelope loss/gain 444 95 2163 519 12 a)Infiltration 166 16 866 84 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)610 112 3029 603 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal6101123029603 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 610 112 3029 603 Air required (cfm)Air required (cfm)16 12 78 67 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 5...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Right-J® Worksheet 9/1/18Date:AH1 Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room10 Room11 2 Exposed wall 16.0 ft 37.5 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft207.4x1.0 ft438.5x1.0 5 Room area 207.4 ft²438.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 4.944.94 0.470.47 113 93 457 44 158 140 689 66.GG 61C61C 0.3200.320 nn 24.3224.32 10.5610.56 20 0 486 211 18 0 438 190 .DD metalmetal 0.1500.150 nn 11.4011.40 2.782.78 0 0 0 0 0 0 0 0 11 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 4.944.94 0.470.47 16 16 78 7 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 4.944.94 0.470.47 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ss 24.3224.32 18.8818.88 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 11.4011.40 2.782.78 0 0 0 0 0 0 0 0WW15B19-0wc-615B19-0wc-6 0.0690.069 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 4.944.94 0.470.47 16 16 78 7 180 180 889 85CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 207 207 315 174 439 439 667 368 FF 19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 207 207 450 83 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --1.901.90 0.000.00 0 0 0 0 65 65 123 0 FF 21A-28c21A-28c 0.0220.022 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 -2 Envelope loss/gain 1864 526 2805 708 12 a)Infiltration 533 52 1248 121 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2397 577 4054 829 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal23975774054829 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2397 577 4054 829 Air required (cfm)Air required (cfm)62 64 105 92 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 6...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Right-J® Worksheet 9/1/18Date:AH1 Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room1 2 Exposed wall 160.0 ft3Room height 9.0 heat/coolft 4 Room dimensions ft1106.0x1.0 5 Room area 1106.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-0wc-6 0.069 n 0.00 0.00 0 0 0 0.W Frm wall, vnl ext, 3 0.065 n 4.94 0.47 378 306 1512 145.G 61C 0.320 n 24.32 10.56 30 0 730 317 .D metal 0.150 n 11.40 2.78 42 42 479 117 11 W 15B19-0wc-6 0.069 e 0.00 0.00 0 0 0 0 W Frm wall, vnl ext, 3 0.065 e 4.94 0.47 342 342 1689 162 W 15B19-0wc-6 0.069 s 0.00 0.00 0 0 0 0G61C0.320 s 0.00 0.00 0 0 0 0 W Frm wall, vnl ext, 3 0.065 s 4.94 0.47 378 296 1464 141G61C0.320 s 24.32 18.88 41 0 991 769 D metal 0.150 s 11.40 2.78 41 41 465 113W15B19-0wc-6 0.069 w 0.00 0.00 0 0 0 0G61C0.320 w 0.00 0.00 0 0 0 0 W Frm wall, vnl ext, 3 0.065 w 4.94 0.47 342 342 1689 162C16B-50ad 0.020 -1.52 0.84 0 0 0 0 F 19A-30bscp 0.034 -2.17 0.40 0 0 0 0 F 21A-24c 0.025 -1.90 0.00 0 0 0 0 F 21A-28c 0.022 -0.00 0.00 0 0 0 0 6 c) AED excursion 231 Envelope loss/gain 9020 2157 12 a)Infiltration 5327 516 b)Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)14346 2673 Less external load 0 0 Less transfer 0 0Redistribution0014Subtotal143462673 15 Duct loads -0%0%0 0 Total room load 14346 2673 Air required (cfm)370 298 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 7...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Right-J® Worksheet 9/1/18Date:basement AH Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name basement AH Room17 2 Exposed wall 151.5 ft 29.5 ft3Room height 9.0 dft 9.0 heat/coolft 4 Room dimensions ft13.0x16.5 5 Room area 1188.5 ft²214.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 3.823.82 0.050.05 279 279 1065 14 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 3.823.82 0.050.05 351 351 1340 17 117 117 447 6 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 3.693.69 0.040.04 383 351 1292 13 149 133 483 5GG61C61C0.3200.320 ss 24.3224.32 18.8818.88 32 0 778 604 16 0 389 302 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW15B19-0wc-615B19-0wc-6 0.0690.069 ww 3.753.75 0.040.04 351 335 1256 15 0 0 0 0GG61C61C0.3200.320 ww 24.3224.32 34.4234.42 16 0 389 551 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 100 100 152 84 8 8 13 7 FF 19A-30bscp19A-30bscp 0.0340.034 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.671.67 0.000.00 1189 1189 1987 0 215 215 359 0 6 c) AED excursion 154 66 Envelope loss/gain 8259 1452 1690 385 12 a)Infiltration 1401 136 273 26 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)9660 1588 1963 411 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal966015881963411 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 9660 1588 1963 411 Air required (cfm)Air required (cfm)567 567 115 147 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 8...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Right-J® Worksheet 9/1/18Date:basement AH Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room15 Room13 2 Exposed wall 57.0 ft 20.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft631.0x1.0 ft8.0x12.0 5 Room area 631.0 ft²96.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B19-0wc-615B19-0wc-6 0.0690.069 nn 3.823.82 0.050.05 0 0 0 0 108 108 412 5.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG 61C61C 0.3200.320 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .DD metalmetal 0.1500.150 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ee 3.823.82 0.050.05 45 45 172 2 72 72 275 4 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 15B19-0wc-615B19-0wc-6 0.0690.069 ss 3.693.69 0.040.04 234 218 809 9 0 0 0 0GG61C61C0.3200.320 ss 24.3224.32 18.8818.88 16 0 389 302 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GG61C61C0.3200.320 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD metalmetal 0.1500.150 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW15B19-0wc-615B19-0wc-6 0.0690.069 ww 3.753.75 0.040.04 234 218 809 9 0 0 0 0GG61C61C0.3200.320 ww 24.3224.32 34.4234.42 16 0 389 551 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 33 33 51 28 30 30 46 25 FF 19A-30bscp19A-30bscp 0.0340.034 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-24c21A-24c 0.0250.025 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF 21A-28c21A-28c 0.0220.022 --1.671.67 0.000.00 631 631 1055 0 96 96 161 0 6 c) AED excursion 98 -4 Envelope loss/gain 3674 999 893 30 12 a)Infiltration 527 51 185 18 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)4201 1050 1078 48 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal42011050107848 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 4201 1050 1078 48 Air required (cfm)Air required (cfm)247 375 63 17 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Sep-01 09:11:32Right-Suite® Universal 2018 18.0.19 RSU20477 Page 9...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Right-J® Worksheet 9/1/18Date:basement AH Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name Room12 2 Exposed wall 45.0 ft3Room height 9.0 heat/coolft 4 Room dimensions ft13.0x19.0 5 Room area 247.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-0wc-6 0.069 n 3.82 0.05 171 171 653 9.W Frm wall, vnl ext, 3 0.065 n 0.00 0.00 0 0 0 0.G 61C 0.320 n 0.00 0.00 0 0 0 0 .D metal 0.150 n 0.00 0.00 0 0 0 0 11 W 15B19-0wc-6 0.069 e 3.82 0.05 117 117 447 6 W Frm wall, vnl ext, 3 0.065 e 0.00 0.00 0 0 0 0 W 15B19-0wc-6 0.069 s 3.69 0.04 0 0 0 0G61C0.320 s 24.32 18.88 0 0 0 0 W Frm wall, vnl ext, 3 0.065 s 0.00 0.00 0 0 0 0G61C0.320 s 0.00 0.00 0 0 0 0 D metal 0.150 s 0.00 0.00 0 0 0 0W15B19-0wc-6 0.069 w 3.75 0.04 117 117 447 6G61C0.320 w 24.32 34.42 0 0 0 0 W Frm wall, vnl ext, 3 0.065 w 0.00 0.00 0 0 0 0C16B-50ad 0.020 -1.52 0.84 28 28 43 24 F 19A-30bscp 0.034 -0.00 0.00 0 0 0 0 F 21A-24c 0.025 -0.00 0.00 0 0 0 0 F 21A-28c 0.022 -1.67 0.00 247 247 413 0 6 c) AED excursion -6 Envelope loss/gain 2002 38 12 a)Infiltration 416 40 b)Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)2418 78 Less external load 0 0 Less transfer 0 0Redistribution0014Subtotal241878 15 Duct loads -0%0%0 0 Total room load 2418 78 Air required (cfm)142 28 Job #: SI307 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 78 Page 1 Right-Suite® Universal 2018 18.0.19 RSU20477 2018-Sep-01 09:11:46 ...\SI307 ashland with basement.rup N 2nd Story Room4Room5 Room6 Room7 Room8 Room9 Room10 Room11 139 cfm 298 cfm 66 cfm 64 cfm 267 cfm 109 cfm 105 cfm 18 cfm 16 cfm 78 cfm Job #: SI307 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 78 Page 2 Right-Suite® Universal 2018 18.0.19 RSU20477 2018-Sep-01 09:11:46 ...\SI307 ashland with basement.rup N Main Floor Room1Room2Room3 53 cfm53 cfm 53 cfm 53 cfm 53 cfm 53 cfm 53 cfm 106 cfm 159 cfm 118 cfm 6 "6 " 6 "6 " 6 " 8 " 6 " 7 " 2-14x3.25 6 " 6 " 2-14x3.25 7 " 6 " 6 " 7 "6 " 6 " 6 "12 cfm 6 "16 x 812 x 8 16 x 8 Job #: SI307 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com Scale: 1 : 78 Page 3 Right-Suite® Universal 2018 18.0.19 RSU20477 2018-Sep-01 09:11:46 ...\SI307 ashland with basement.rup N basement Room12 Room13 Room14 Room15 Room17 147 cfm 125 cfm125 cfm 142 cfm 71 cfm 63 cfm 125 cfm 392 cfm 71 cfm 6 "6 " 6 " 7 " 6 " 5 x 8 10 x 8 7 " 73 cfm 6 x 8 6 " 73 cfm 6 " 6 "2-14x3.25 2018-Sep-01 09:11:33 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 1 ...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Duct System Summary 9/1/18Date:AH1 Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.30in H2O0.30 Available static pressure in H2O0.40in H2O0.40 Supply / return available pressure 0.218 / 0.182 in H2O in H2O0.218 / 0.182 Lowest friction rate in/100ft0.078in/100ft0.078 Actual air flow cfm867cfm867 Total effective length (TEL)ft513 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk 00ShMt0x0004353382hRoom1 st4230.034.3ShMt0x06.00.08243532049hRoom1-A st3160.015.8ShMt0x06.00.12443532049hRoom1-B st4200.040.3ShMt0x06.00.09143532049hRoom1-C st4175.03.3ShMt0x06.00.12243532049hRoom1-D st4210.045.8ShMt0x06.00.08543532049hRoom1-E st4245.034.3ShMt0x06.00.07843532049hRoom1-F st4160.030.3ShMt0x06.00.1156462577cRoom10 st4220.042.8ShMt0x07.00.083921054054hRoom11 st4240.08.8ShMt0x06.00.088512467hRoom2-A st4235.030.8ShMt0x07.00.082139971250cRoom4 st4240.014.3ShMt0x06.00.0866632594cRoom5 st3205.017.8ShMt0x07.00.09810976980cRoom6 st3215.05.3ShMt0x06.00.0991418695hRoom7 st3160.09.3ShMt0x06.00.1291216610hRoom8 st3195.027.3ShMt0x06.00.09867783029hRoom9 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 241 245 0.098 367 8.2 12x8 ShtMetl st4 Peak AVF 573 580 0.078 652 11.8 16x8 ShtMetl 2018-Sep-01 09:11:33 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 2 ...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb15 0x 1060 85 134.8 0.135 539 6.0 x0 0 ShMt rt3 rb18 0x 2340 298 152.3 0.120 471 8.4 2-3.25x14 2-10x18 SJSp rt3 rb19 0x 2500 267 182.8 0.100 422 8.4 2-3.25x14 2-10x18 SJSp rb16 0x 1590 128 233.3 0.078 455 8.0 x0 0 ShMt rt3 rb17 0x 1180 90 84.8 0.215 600 6.0 x0 0 ShMt rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt3 Peak AVF 617 600 0.078 694 12.1 16x8 ShtMetl 2018-Sep-01 09:11:33 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 3 ...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N SI307Job:Duct System Summary 9/1/18Date:basement AH Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.30in H2O0.30 Available static pressure in H2O0.40in H2O0.40 Supply / return available pressure 0.263 / 0.137 in H2O in H2O0.263 / 0.137 Lowest friction rate in/100ft0.086in/100ft0.086 Actual air flow cfm567cfm567 Total effective length (TEL)ft464 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st2175.045.5ShMt0x06.00.11914711209hRoom12 st2140.033.5ShMt0x06.00.15114711209hRoom12-A st1290.014.5ShMt0x06.00.08617631078hRoom13 st2175.045.0ShMt0x07.00.11912582350cRoom15 st2140.033.5ShMt0x06.00.15112582350cRoom15-A st2150.023.5ShMt0x06.00.15112582350cRoom15-B st1225.025.5ShMt0x06.00.1057358206cRoom17 st1160.022.0ShMt0x06.00.1447358206cRoom17-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 178 164 0.086 535 7.5 6x8 ShtMetl st2 Peak AVF 389 403 0.119 725 9.5 10x8 ShtMetl 2018-Sep-01 09:11:33 Right-Suite® Universal 2018 18.0.19 RSU20477 Page 4 ...tware\Kartchner\SI307 ashland with basement.rup Calc = MJ8 House faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 3100 392 63.6 0.216 621 8.3 2-3.25x14 2-10x18 SJSp rb14 0x 1420 28 159.0 0.086 511 6.8 x8 5 ShMt rb11 0x 1150 147 66.0 0.208 550 7.0 x0 0 ShMt