Loading...
HomeMy WebLinkAboutUTILITY PLANS - 18-00469 - Thomson Farms the Grove - ClubhouseEE GV WV WV WV WV WV x x x x x x x x x x x x x x x x x x x ss ohp x gggg g g g g g w w w w w w w w w w w w w w w w W W W W W W WWWWW W W W W WV G G G G G WV WV WV WV W W W WWWWWV WV WV WV WV WV WV WV WV WV WV WV WV WV WV WV W WV WV WV WV WV WV WV W V W V W V W W W H YD HYD H YD HYD HYD G G G G G G G G G G G G G G G G G G G G G GGGG G G G G G G G WV WV H Y D W W WVWV WV H YD WV H YD HYD WV WWWWWWWW W W W W G G G W W W W W W W W W W W W W W W W W W W W W W WVWV WV WV W W W W W W W W WV W V GV WV WV WV WV WV WV WV WV WV WVWV WV HYD HYD H YD G G G G G G G G W V WV HYD HYD HYD HYD WV WV WV W G G G G G G G G G H Y D W W W W W W W W W W W W W W W WV WV WV WVWV W V W W W W W W W W W FF=4876.40 HYD SS SS SS WW SS SS W SS W W W SS W SS W W W W W W S S S S W W W WWWWW W W W W W W W G G G G G G G G G G G G G G FF=4876.00 FF=4876.12 FF=4877.45 FF=4875.90 FF=4876.25 FF=4876.45 FF=4876.85 FF=4876.60 FF=4876.65 FF=4877.94 FF=4876.80 POOL & HOT TUB CLUBHOUSE LINDEN: BUILDING 11 TYPE-A (30 UNITS) ALDERWOOD: BUILDING 1 TYPE-A (30 UNITS) PONDERODSA: BUILDING 2 TYPE-A (30 UNITS) WHITEPINE: BUILDING 3 TYPE-B (20 UNITS) MAPLEWOOD: BUILDING 9 TYPE-A (30 UNITS) BIRCHWOOD: BUILDING 10 TYPE-A (30 UNITS) HAWTHORN: BUILDING 7 TYPE-A (30 UNITS) HAZELWOOD: BUILDING 4 TYPE-B (20 UNITS) HEMLOCK: BUILDING 8 TYPE-A (30 UNITS) BLACKOAK: BUILDING 5 TYPE-B (20 UNITS) HICKORY: BUILDING 6 TYPE-A (30 UNITS) CO BARN SS SS SS S S S S CO SS CO CO CO CO CO CO CO CO CO CO CO FF=4876.40 HYD HYD WV WV WV WV WV WV WV WV HYD HYD H YD WV H YDWV HYD W V SS WV OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OH P OH P FUTURE DEVELOPMENT FUTURE DEVELOPMENT FUTURE DEVELOPMENT SS CO WW FDC FDC FDC FDC FDC FDC FDC FDC FDC FDC FDC W V HYD S S S S S S S S S S S S S S S S S S S S S ss ss ss ss ss ss ss ss ss ss ss ss ssssss SSSS SS SS SS SS SS SS ssssss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uite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 WWW.ENSIGNENG.CO E N S I G N THE STANDARD IN ENGINEERING 7835A TH E G R O V E A T T H O M S O N F A R M S 47 2 N O R T H Y E L L O W S T O N E H W Y RE X B U R G , I D A H O REXBURG DEVELOPMENT 160 WEST CANYON ESTATE DRIVE ALPINE, UTAH 84004 PAUL BRINHURST 385-321-1403 J. FORD J. FORDD. COWLEY 8/31/18 2018-05-23 FOR REVIEW CALL DIGLINE @ 811 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.Know what'sbelow. before you dig.Call R FOUND MONUMENT AT THE SOUTHEAST QUARTER OF SECTION 17,T6N, R40E, BOISE B&M ELEVATION = 4875.15 BENCHMARK HORIZONTAL GRAPHIC SCALE 0 ( IN FEET ) HORZ: 1 inch = ft.80 80 40 80 160 C-500 OVERALL UTILITY PLAN WV WV WV x x x x x x x x x x x x x x x x x x x x x ss ohpx x x ggggggggggggg w w w w w w w w w w w w w w w w w W W W W W W W W W V WV WV W W W W W G G G G G H Y D OHP OHP OH P OHP OH P OH P OH P OH P OHP OH P OHP S D S ss ss ss ss ss ss ss ssssssssssssssss EXIST. SSMH #104EX RIM=4875.04 FL(OUT-SW)=4862.72 FL(IN-E)=4862.72 EXIST. 12" SAN SWR 402.93 L.F. @ 0.24% SLOPE EXIST. 8" SAN SWR 369.01 L.F. @ 0.68% SLOPE D S D SD SD EXIST 12" WATER LINE EXIST 12" WATER LINE INSTALL 10" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE INSTALL 45° BEND INSTALL 11.25° BEND INSTALL 12"x10" TEE WITH (2) 12" BUTTERFLY VALVES AND (1) 10" GATE VALVE CONNECT TO EXISTING WATER LINE INSTALL 11.25° BEND INSTALL 22.5° BEND 8 4 10 10 10 OLD U . S . H I G H W A Y 1 9 1 ST E G E L M E I E R L A N E PH A S E 3 PH A S E 1 PHASE 3 FUTU R E SD 1.ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2.EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'S FAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION IN THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THE CONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TO REMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE. 3.ALL SANITARY SEWER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 4.ALL WATER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 6.DEFLECT OR LOOP ALL WATERLINES TO AVOID CONFLICTS WITH OTHER UTILITIES PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 7.PROJECT SHALL COMPLY WITH ALL IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION DRINKING WATER RULES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO, THOSE PERTAINING TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. 8.THE CONTRACTOR IS TO COORDINATE ALL UTILITIES WITH MECHANICAL/PLUMBING PLANS. 9.NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING UTILITY STRUCTURES OR PIPES. 10.THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 11.THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC. UNLESS OTHERWISE NOTED ON THESE PLANS. 12.SEE LANDSCAPE/MECHANICAL PLANS FOR IRRIGATION POINT OF CONNECTION LOCATIONS. GENERAL NOTES SCOPE OF WORK: PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 6" SDR-35 PVC SANITARY SEWER LATERAL, INCLUDING CLEANOUTS. CONNECT TO EXISTING SEWER MAIN PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2" POLY LATERAL WITH 2" CULINARY WATER METER. 2 1/2" LATERAL EXTENDING FROM METER TO BUILDING PER REXBURG STANDARDS. FIRE HYDRANT ASSEMBLY COMPLETE PER ISPWC STANDARD DRAWING SD-404. 4" CL-52 D.I. FIRE LINE. ENSURE (1) FULL PIPE LENGTH IS INSTALLED BEYOND VALVE. STUB, CAP AND MARK FOR FUTURE WATER LINE CONNECTION. INSTALL TEMPORARY BLOW-OFF/WASHOUT VALVE. SEE MECHANICAL PLANS FOR CONTINUATION. GAS LINE PER INTERMOUNTAIN GAS STANDARDS (SHOWN FOR REFERENCE ONLY). BLIND FLANGE ON VALVE FOR FUTURE CONNECTION. RELOCATED POWER POLE AND OVERHEAD POWER LINE BY LOCAL POWER COMPANY. ROTATE MANHOLE LID TO FURTHEST POSITION FROM CURB AND GUTTER FLOW LINE (EITHER DIRECTION). FIRE DEPARTMENT CONNECTION (SEE PLUMMING DRAWINGS). 7 8 9 1 2 3 4 5 6 10 11 12 CHECKED BYDRAWN BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: SALT LAKE CITY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 WWW.ENSIGNENG.CO E N S I G N THE STANDARD IN ENGINEERING 7835A TH E G R O V E A T T H O M S O N F A R M S 47 2 N O R T H Y E L L O W S T O N E H W Y RE X B U R G , I D A H O REXBURG DEVELOPMENT 160 WEST CANYON ESTATE DRIVE ALPINE, UTAH 84004 PAUL BRINHURST 385-321-1403 J. FORD J. FORDD. COWLEY 8/31/18 2018-05-23 FOR REVIEW CALL DIGLINE @ 811 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.Know what'sbelow. before you dig.Call R FOUND MONUMENT AT THE SOUTHEAST QUARTER OF SECTION 17,T6N, R40E, BOISE B&M ELEVATION = 4875.15 BENCHMARK HORIZONTAL GRAPHIC SCALE 0 ( IN FEET ) HORZ: 1 inch = ft.20 20 10 20 40 C-501 UTILITY PLAN SEE DRAWING C-503SEE DRAWING C-503 SE E D R A W I N G C - 5 0 2 SE E D R A W I N G C - 5 0 2 KEYMAP NOT TO SCALE EE GV x x x x x x x g gggggg g g g g g g g g g g g g g g g EXIST BLG EXIST BLG EXIST BLG EXIST BLG EXIST BLG G G W W W W W W W W W W W W W W W W W W W W W W W W W WVWV WV W W W W W W W W W W W W WV W V GV H Y D G G G G G G G W W W W W WV WVWV W V SS SS SS SS SS SS SS SS W W W W W W W W W S S S S S S S S S S S S S S W W W W W W G G G G G G G G G G G G G G G G G G CO W H Y D WV H Y D W V WV SD SD SD SD SD SD SD S D D SD F D C FDC DD D D SD SD SD SD SD SD SD SD SD SD S S S S ssssssssssssssssssssssssssssssssssssssss S S S S S S S S S S S S SS SS SS SS SS INSTALL 4' SSMH #122 RIM=4875.15 FL(OUT-E)=4866.46 EXIST. SSMH #105EX RIM=4874.84 FL(IN-E)=4865.24 FL(OUT-W)=4865.24 FL(IN-S)=4865.74 INSTALL 5' SSMH #121 RIM=4874.88 FL(OUT-N)=4866.10 FL(IN-W)=4866.20 INSTALL 5' SSMH #125 RIM=4874.94 FL(IN-E)=4866.37 FL(OUT-W)=4866.37 FL(IN-S)=4866.87 EXIST. 8" SAN SWR 52.74 L.F. @ 0.36% SLOPE EXIST. 8" SAN SWR 369.01 L.F. @ 0.68% SLOPE EXIST. 8" SAN SWR 309.21 L.F. @ 0.36% SLOPE INSTALL 8" SDR-35 PVC-SAN SWR 341.81 L.F. @ 0.40% SLOPE INSTALL 8" SDR-35 PVC-SAN SWR 90.43 L.F. @ 0.40% SLOPE INSTALL 8" SDR-35 PVC-SAN SWR 65.74 L.F. @ 0.40% SLOPE 2 1 1 22 INSTALL 10" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE INSTALL 10"x8" TEE WITH (2) 10" GATE VALVES AND (1) 8" GATE VALVE 4 INSTALL 10" CL-52 D.I. WATER LINE INSTALL 10" CL-52 D.I. WATER LINE INSTALL 10" TEE WITH (3) 10" GATE VALVES 4 INSTALL 10" GATE VALVE 3 7 3 9 9 54 INSTALL 8" TEE WITH (3) 8" GATE VALVES INSTALL 8" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE 5 8 8 8 ST O N E B R I D G E S T R E E T STEGELMEIER LANE 8 PHASE 3 FUTURE PH A S E 3 FU T U R E 11 11 S D S D 1.ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2.EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'S FAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION IN THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THE CONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TO REMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE. 3.ALL SANITARY SEWER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 4.ALL WATER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 6.DEFLECT OR LOOP ALL WATERLINES TO AVOID CONFLICTS WITH OTHER UTILITIES PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 7.PROJECT SHALL COMPLY WITH ALL IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION DRINKING WATER RULES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO, THOSE PERTAINING TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. 8.THE CONTRACTOR IS TO COORDINATE ALL UTILITIES WITH MECHANICAL/PLUMBING PLANS. 9.NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING UTILITY STRUCTURES OR PIPES. 10.THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 11.THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC. UNLESS OTHERWISE NOTED ON THESE PLANS. 12.SEE LANDSCAPE/MECHANICAL PLANS FOR IRRIGATION POINT OF CONNECTION LOCATIONS. GENERAL NOTES SCOPE OF WORK: PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 6" SDR-35 PVC SANITARY SEWER LATERAL, INCLUDING CLEANOUTS. CONNECT TO EXISTING SEWER MAIN PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2" POLY LATERAL WITH 2" CULINARY WATER METER. 2 1/2" LATERAL EXTENDING FROM METER TO BUILDING PER REXBURG STANDARDS. FIRE HYDRANT ASSEMBLY COMPLETE PER ISPWC STANDARD DRAWING SD-404. 4" CL-52 D.I. FIRE LINE. ENSURE (1) FULL PIPE LENGTH IS INSTALLED BEYOND VALVE. STUB, CAP AND MARK FOR FUTURE WATER LINE CONNECTION. INSTALL TEMPORARY BLOW-OFF/WASHOUT VALVE. SEE MECHANICAL PLANS FOR CONTINUATION. GAS LINE PER INTERMOUNTAIN GAS STANDARDS (SHOWN FOR REFERENCE ONLY). BLIND FLANGE ON VALVE FOR FUTURE CONNECTION. RELOCATED POWER POLE AND OVERHEAD POWER LINE BY LOCAL POWER COMPANY. ROTATE MANHOLE LID TO FURTHEST POSITION FROM CURB AND GUTTER FLOW LINE (EITHER DIRECTION). FIRE DEPARTMENT CONNECTION (SEE PLUMMING DRAWINGS). 7 8 9 1 2 3 4 5 6 10 11 12 CHECKED BYDRAWN BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: SALT LAKE CITY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 WWW.ENSIGNENG.CO E N S I G N THE STANDARD IN ENGINEERING 7835A TH E G R O V E A T T H O M S O N F A R M S 47 2 N O R T H Y E L L O W S T O N E H W Y RE X B U R G , I D A H O REXBURG DEVELOPMENT 160 WEST CANYON ESTATE DRIVE ALPINE, UTAH 84004 PAUL BRINHURST 385-321-1403 J. FORD J. FORDD. COWLEY 8/31/18 2018-05-23 FOR REVIEW CALL DIGLINE @ 811 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.Know what'sbelow. before you dig.Call R FOUND MONUMENT AT THE SOUTHEAST QUARTER OF SECTION 17,T6N, R40E, BOISE B&M ELEVATION = 4875.15 BENCHMARK HORIZONTAL GRAPHIC SCALE 0 ( IN FEET ) HORZ: 1 inch = ft.20 20 10 20 40 C-502 UTILITY PLAN SEE DRAWING C-504SEE DRAWING C-504 SE E D R A W I N G C - 5 0 1 SE E D R A W I N G C - 5 0 1 KEYMAP NOT TO SCALE WV x x x x x x x x x x x x x x x x w w w w w w w w w w w w w w w w w w w w W W W W W W W W W W W W W W W W W W H Y D W W W W W W W W H Y D W W SS SS SS SS WW W W W W SS SS SS SS SS SS W W W W W W W W W W W W W W W G G G G G G G G G G G G G G G G G G G G G G G FF=4876.45 FF=4876.80 MAPLEWOOD: BUILDING 9 TYPE-A (30 UNITS) BIRCHWOOD: BUILDING 10 TYPE-A (30 UNITS) CO CO H Y D WV WV WV WV WV WV OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP FDC F D C W V H YD OLD U . S . H I G H W A Y 1 9 1 D D S D S D S D S D S D SD SD SD SD SD SD SD SD SD SD SD SD S D SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD S S S ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS 1 7 INSTALL 8" SDR-35 PVC-SAN SWR 218.57 L.F. @ 0.40% SLOPE INSTALL 5' SSMH #109 RIM=4873.80 FL(IN-NE)=4863.15 FL(IN-SE)=4863.15 FL(OUT-SW)=4863.05 INSTALL 8" SDR-35 PVC-SAN SWR 202.50 L.F. @ 0.40% SLOPE INSTALL 8" SDR-35 PVC-SAN SWR 223.08 L.F. @ 0.40% SLOPE 1 7 EXIST. 12" SAN SWR 402.93 L.F. @ 0.24% SLOPE EXIST. 12" SAN SWR 316.78 L.F. @ 0.18% SLOPE EXIST. SSMH #103EX RIM=4874.02 FL(IN-NE)=4861.74 FL(OUT-SW)=4861.74 EXIST 12" WATER LINE INSTALL 8" CL-52 D.I. WATER LINE INSTALL 90° BEND INSTALL 12"x8" TEE WITH (2) 12" BUTTERFLY VALVES AND (1) 8" GATE VALVE CONNECT TO EXISTING WATER LINE INSTALL 22.5° BEND 3 5 7 7 3 5 EXIST 12" WATER LINE 4 INSTALL 8" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE INSTALL 22.5° BEND 4 INSTALL 8" CROSS WITH 8" GATE VALVE INSTALL 8" CL-52 D.I. WATER LINE 9 8 8 PHA S E 1 PH A S E 3 INSTALL 4' SSMH #110 RIM=4874.81 FL(OUT-SW)=4864.0210 10 10 PH A S E 3 PH A S E 1 4 SD SD SD SD 12 12 4 1.ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2.EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'S FAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION IN THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THE CONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TO REMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE. 3.ALL SANITARY SEWER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 4.ALL WATER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 6.DEFLECT OR LOOP ALL WATERLINES TO AVOID CONFLICTS WITH OTHER UTILITIES PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 7.PROJECT SHALL COMPLY WITH ALL IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION DRINKING WATER RULES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO, THOSE PERTAINING TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. 8.THE CONTRACTOR IS TO COORDINATE ALL UTILITIES WITH MECHANICAL/PLUMBING PLANS. 9.NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING UTILITY STRUCTURES OR PIPES. 10.THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 11.THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC. UNLESS OTHERWISE NOTED ON THESE PLANS. 12.SEE LANDSCAPE/MECHANICAL PLANS FOR IRRIGATION POINT OF CONNECTION LOCATIONS. GENERAL NOTES SCOPE OF WORK: PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 6" SDR-35 PVC SANITARY SEWER LATERAL, INCLUDING CLEANOUTS. CONNECT TO EXISTING SEWER MAIN PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2" POLY LATERAL WITH 2" CULINARY WATER METER. 2 1/2" LATERAL EXTENDING FROM METER TO BUILDING PER REXBURG STANDARDS. FIRE HYDRANT ASSEMBLY COMPLETE PER ISPWC STANDARD DRAWING SD-404. 4" CL-52 D.I. FIRE LINE. ENSURE (1) FULL PIPE LENGTH IS INSTALLED BEYOND VALVE. STUB, CAP AND MARK FOR FUTURE WATER LINE CONNECTION. INSTALL TEMPORARY BLOW-OFF/WASHOUT VALVE. SEE MECHANICAL PLANS FOR CONTINUATION. GAS LINE PER INTERMOUNTAIN GAS STANDARDS (SHOWN FOR REFERENCE ONLY). BLIND FLANGE ON VALVE FOR FUTURE CONNECTION. RELOCATED POWER POLE AND OVERHEAD POWER LINE BY LOCAL POWER COMPANY. ROTATE MANHOLE LID TO FURTHEST POSITION FROM CURB AND GUTTER FLOW LINE (EITHER DIRECTION). FIRE DEPARTMENT CONNECTION (SEE PLUMMING DRAWINGS). 7 8 9 1 2 3 4 5 6 10 11 12 CHECKED BYDRAWN BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: SALT LAKE CITY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 WWW.ENSIGNENG.CO E N S I G N THE STANDARD IN ENGINEERING 7835A TH E G R O V E A T T H O M S O N F A R M S 47 2 N O R T H Y E L L O W S T O N E H W Y RE X B U R G , I D A H O REXBURG DEVELOPMENT 160 WEST CANYON ESTATE DRIVE ALPINE, UTAH 84004 PAUL BRINHURST 385-321-1403 J. FORD J. FORDD. COWLEY 8/31/18 2018-05-23 FOR REVIEW CALL DIGLINE @ 811 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.Know what'sbelow. before you dig.Call R FOUND MONUMENT AT THE SOUTHEAST QUARTER OF SECTION 17,T6N, R40E, BOISE B&M ELEVATION = 4875.15 BENCHMARK HORIZONTAL GRAPHIC SCALE 0 ( IN FEET ) HORZ: 1 inch = ft.20 20 10 20 40 C-503 UTILITY PLAN SEE DRAWING C-501SEE DRAWING C-501 SE E D R A W I N G C - 5 0 4 SE E D R A W I N G C - 5 0 4 SEE DRAWING C-506SEE DRAWING C-506 KEYMAP NOT TO SCALE SE E D R A W I N G C - 5 0 5 WV WV WV H Y D GG W W W W W W W W W W W W W W W W W W H Y D G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W WV SS SS S S S S SS GGG W W W G G G S S S S S S S S W WWW W GGGG WWWW W FF=4877.45 FF=4876.85 FF=4877.94 POOL & HOT TUB ALDERWOOD: BUILDING 1 TYPE-A (30 UNITS) PONDERODSA: BUILDING 2 TYPE-A (30 UNITS) WHITEPINE: BUILDING 3 TYPE-B (20 UNITS) BARN CO SSSSSSSSSSSS CO CO CO FF=4876.40 H Y D WV SD SD SD SD SD SD SD SD SD SD SD S D S D S D S D D SD SD SD SD SD SD SD SD SD SD SD SD SD SD F D C FD C FDC FDC D D D SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD S D S D SD SD SD S D SD S D S S S S S S S S S S S S S S S S S INSTALL 4' SSMH #126 RIM=4876.34 FL(OUT-N)=4868.24 FL(IN-E)=4868.29 PLUG, CAP, AND MARK FOR FUTURE CONNECTION #127 RIM=4869.09 FL(OUT-W)=4868.37 INSTALL 8" SDR-35 PVC-SAN SWR 341.81 L.F. @ 0.40% SLOPE INSTALL 8" SDR-35 PVC-SAN SWR 20.00 L.F. @ 0.40% SLOPE 1 1 7 7 INSTALL 8" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE 3 5 7 7 7 5 5 3 3 4 4 8 8 INSTALL 8" CL-52 D.I. WATER LINE ST O N E B R I D G E S T R E E T PH A S E 3 FU T U R E PH A S E 2 FU T U R E PHASE 3 PHASE 2 PHASE 3 PHASE 2 P H A S E 2 P H A S E 1 8 8 FUTURE WATER LINE FUTURE WATER LINE SD SD S D S D S D S D 12 12 12 12 1.ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2.EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'S FAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION IN THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THE CONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TO REMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE. 3.ALL SANITARY SEWER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 4.ALL WATER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 6.DEFLECT OR LOOP ALL WATERLINES TO AVOID CONFLICTS WITH OTHER UTILITIES PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 7.PROJECT SHALL COMPLY WITH ALL IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION DRINKING WATER RULES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO, THOSE PERTAINING TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. 8.THE CONTRACTOR IS TO COORDINATE ALL UTILITIES WITH MECHANICAL/PLUMBING PLANS. 9.NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING UTILITY STRUCTURES OR PIPES. 10.THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 11.THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC. UNLESS OTHERWISE NOTED ON THESE PLANS. 12.SEE LANDSCAPE/MECHANICAL PLANS FOR IRRIGATION POINT OF CONNECTION LOCATIONS. GENERAL NOTES SCOPE OF WORK: PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 6" SDR-35 PVC SANITARY SEWER LATERAL, INCLUDING CLEANOUTS. CONNECT TO EXISTING SEWER MAIN PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2" POLY LATERAL WITH 2" CULINARY WATER METER. 2 1/2" LATERAL EXTENDING FROM METER TO BUILDING PER REXBURG STANDARDS. FIRE HYDRANT ASSEMBLY COMPLETE PER ISPWC STANDARD DRAWING SD-404. 4" CL-52 D.I. FIRE LINE. ENSURE (1) FULL PIPE LENGTH IS INSTALLED BEYOND VALVE. STUB, CAP AND MARK FOR FUTURE WATER LINE CONNECTION. INSTALL TEMPORARY BLOW-OFF/WASHOUT VALVE. SEE MECHANICAL PLANS FOR CONTINUATION. GAS LINE PER INTERMOUNTAIN GAS STANDARDS (SHOWN FOR REFERENCE ONLY). BLIND FLANGE ON VALVE FOR FUTURE CONNECTION. RELOCATED POWER POLE AND OVERHEAD POWER LINE BY LOCAL POWER COMPANY. ROTATE MANHOLE LID TO FURTHEST POSITION FROM CURB AND GUTTER FLOW LINE (EITHER DIRECTION). FIRE DEPARTMENT CONNECTION (SEE PLUMMING DRAWINGS). 7 8 9 1 2 3 4 5 6 10 11 12 CHECKED BYDRAWN BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: SALT LAKE CITY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 WWW.ENSIGNENG.CO E N S I G N THE STANDARD IN ENGINEERING 7835A TH E G R O V E A T T H O M S O N F A R M S 47 2 N O R T H Y E L L O W S T O N E H W Y RE X B U R G , I D A H O REXBURG DEVELOPMENT 160 WEST CANYON ESTATE DRIVE ALPINE, UTAH 84004 PAUL BRINHURST 385-321-1403 J. FORD J. FORDD. COWLEY 8/31/18 2018-05-23 FOR REVIEW CALL DIGLINE @ 811 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.Know what'sbelow. before you dig.Call R FOUND MONUMENT AT THE SOUTHEAST QUARTER OF SECTION 17,T6N, R40E, BOISE B&M ELEVATION = 4875.15 BENCHMARK HORIZONTAL GRAPHIC SCALE 0 ( IN FEET ) HORZ: 1 inch = ft.20 20 10 20 40 C-504 UTILITY PLAN SEE DRAWING C-507SEE DRAWING C-507 SE E D R A W I N G C - 5 0 3 SE E D R A W I N G C - 5 0 3 SEE DRAWING C-502SEE DRAWING C-502 KEYMAP NOT TO SCALE x x x x x x x x x x x x x x x x x x x x x w w w w w w w w w w w w w w w w WV WV WV OHP OHP OHP OHP OHP OHP OHP O OHP OHP OHP OHP D D SD SD SD SD SD S S ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss SS SS SS EXIST. 12" SAN SWR 316.78 L.F. @ 0.18% SLOPE INSTALL 5' SSMH #107 RIM=4873.67 FL(IN-NE)=4861.16 FL(OUT-SW)=4861.16 FL(IN-SE)=4861.66 INSTALL 12" SDR-35 PVC-SAN SWR 139.76 L.F. @ 0.22% SLOPE EXIST. 12" SAN SWR 80.65 L.F. @ 0.18% SLOPE EXIST. SSMH #102EX RIM=4874.11 FL(IN-NE)=4861.01 FL(OUT-SW)=4861.01 EXIST. 12" SAN SWR 397.95 L.F. @ 0.24% SLOPE 2 INSTALL 12"x10" TEE WITH (2) 12" BUTTERFLY VALVES AND (1) 10" GATE VALVE CONNECT TO EXISTING WATER LINE EXIST 12" WATER LINE OLD U . S . H I G H W A Y 1 9 1 PHA S E 1 FU T U R E 10 10 1.ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2.EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'S FAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION IN THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THE CONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TO REMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE. 3.ALL SANITARY SEWER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 4.ALL WATER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 6.DEFLECT OR LOOP ALL WATERLINES TO AVOID CONFLICTS WITH OTHER UTILITIES PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 7.PROJECT SHALL COMPLY WITH ALL IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION DRINKING WATER RULES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO, THOSE PERTAINING TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. 8.THE CONTRACTOR IS TO COORDINATE ALL UTILITIES WITH MECHANICAL/PLUMBING PLANS. 9.NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING UTILITY STRUCTURES OR PIPES. 10.THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 11.THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC. UNLESS OTHERWISE NOTED ON THESE PLANS. 12.SEE LANDSCAPE/MECHANICAL PLANS FOR IRRIGATION POINT OF CONNECTION LOCATIONS. GENERAL NOTES SCOPE OF WORK: PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 6" SDR-35 PVC SANITARY SEWER LATERAL, INCLUDING CLEANOUTS. CONNECT TO EXISTING SEWER MAIN PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2" POLY LATERAL WITH 2" CULINARY WATER METER. 2 1/2" LATERAL EXTENDING FROM METER TO BUILDING PER REXBURG STANDARDS. FIRE HYDRANT ASSEMBLY COMPLETE PER ISPWC STANDARD DRAWING SD-404. 4" CL-52 D.I. FIRE LINE. ENSURE (1) FULL PIPE LENGTH IS INSTALLED BEYOND VALVE. STUB, CAP AND MARK FOR FUTURE WATER LINE CONNECTION. INSTALL TEMPORARY BLOW-OFF/WASHOUT VALVE. SEE MECHANICAL PLANS FOR CONTINUATION. GAS LINE PER INTERMOUNTAIN GAS STANDARDS (SHOWN FOR REFERENCE ONLY). BLIND FLANGE ON VALVE FOR FUTURE CONNECTION. RELOCATED POWER POLE AND OVERHEAD POWER LINE BY LOCAL POWER COMPANY. ROTATE MANHOLE LID TO FURTHEST POSITION FROM CURB AND GUTTER FLOW LINE (EITHER DIRECTION). FIRE DEPARTMENT CONNECTION (SEE PLUMMING DRAWINGS). 7 8 9 1 2 3 4 5 6 10 11 12 CHECKED BYDRAWN BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: SALT LAKE CITY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 WWW.ENSIGNENG.CO E N S I G N THE STANDARD IN ENGINEERING 7835A TH E G R O V E A T T H O M S O N F A R M S 47 2 N O R T H Y E L L O W S T O N E H W Y RE X B U R G , I D A H O REXBURG DEVELOPMENT 160 WEST CANYON ESTATE DRIVE ALPINE, UTAH 84004 PAUL BRINHURST 385-321-1403 J. FORD J. FORDD. COWLEY 8/31/18 2018-05-23 FOR REVIEW CALL DIGLINE @ 811 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.Know what'sbelow. before you dig.Call R FOUND MONUMENT AT THE SOUTHEAST QUARTER OF SECTION 17,T6N, R40E, BOISE B&M ELEVATION = 4875.15 BENCHMARK HORIZONTAL GRAPHIC SCALE 0 ( IN FEET ) HORZ: 1 inch = ft.20 20 10 20 40 C-505 UTILITY PLAN SEE DRAWING C-508SEE DRAWING C-508 SE E D R A W I N G C - 5 0 6 SE E D R A W I N G C - 5 0 6 SE E D R A W I N G C - 5 0 3 KEYMAP NOT TO SCALE w w w w G G G G G G G G G G G G G G G G G G G G G G W W W W H Y D W W WV WV WV WVWV WV WV H Y D W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS W W W W W W W W W W W W W W W W W SS W W W W W W G G G G G G G G G FF=4876.25 FF=4876.60 HAWTHORN: BUILDING 7 TYPE-A (30 UNITS) HEMLOCK: BUILDING 8 TYPE-A (30 UNITS) CO CO WV H Y D SS SS SS SS SS SS OHP OHP OHP OHP OHP OHP SS SS SS SS SS SS SS SS SS CO W W SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD D SD SD D SD SD SD SD SD FDC FDC D D D SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD S S S S SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS INSTALL 5' SSMH #108 RIM=4875.21 FL(IN-SE)=4862.02 FL(OUT-NW)=4861.97 FL(IN-NE)=4862.24 INSTALL 4' SSMH #113 RIM=4875.01 FL(IN-SE)=4862.56 FL(OUT-NW)=4862.51 INSTALL 4' SSMH #111 RIM=4874.49 FL(OUT-NW)=4864.04 FL(IN-E)=4864.09 INST A L L 1 2 " S D R - 3 5 P V C - S A N S W R 2 6 4 . 1 6 L . F . @ 0 . 2 2 % S L O P E INS T A L L 1 2 " S D R - 3 5 P V C - S A N S W R 2 2 3 . 0 8 L . F . @ 0 . 2 2 % S L O P E INS T A L L 8 " S D R - 3 5 P V C - S A N S W R 2 2 3 . 0 8 L . F . @ 0 . 4 0 % S L O P E INSTALL 8" SDR-35 PVC-SAN SWR 270.29 L.F. @ 0.40% SLOPE INSTALL 12" SDR-35 PVC-SAN SWR 139.76 L.F. @ 0.22% SLOPE IN S T A L L 8 " S D R - 3 5 P V C - S A N S W R 2 0 2 . 5 0 L . F . @ 0 . 4 0 % S L O P E 1 1 7 7 INSTALL 4' SSMH #114 RIM=4874.58 FL(IN-E)=4863.19 FL(OUT-NW)=4863.14 INSTALL 8" CL-52 D.I. WATER LINE INSTALL 12"x10" TEE WITH (2) 12" BUTTERFLY VALVES AND (1) 10" GATE VALVE CONNECT TO EXISTING WATER LINE 7 3 5 4INSTALL 8" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE 7 3 5 4 6 INSTALL 8" CL-52 D.I. WATER LINE INSTALL 10"x8" CROSS WITH (2) 10" GATE VALVES AND (2) 8" GATE VALVE INSTALL 10" CL-52 D.I. WATER LINE INSTALL 10" CL-52 D.I. WATER LINE 8OL D U . S . H I G H W A Y 1 9 1 PHA S E 1 FUT U R E TH O M S O N F A R M S R O A D 1 D SD SD SD SD SD 12 12 1.ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2.EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'S FAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION IN THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THE CONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TO REMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE. 3.ALL SANITARY SEWER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 4.ALL WATER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 6.DEFLECT OR LOOP ALL WATERLINES TO AVOID CONFLICTS WITH OTHER UTILITIES PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 7.PROJECT SHALL COMPLY WITH ALL IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION DRINKING WATER RULES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO, THOSE PERTAINING TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. 8.THE CONTRACTOR IS TO COORDINATE ALL UTILITIES WITH MECHANICAL/PLUMBING PLANS. 9.NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING UTILITY STRUCTURES OR PIPES. 10.THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 11.THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC. UNLESS OTHERWISE NOTED ON THESE PLANS. 12.SEE LANDSCAPE/MECHANICAL PLANS FOR IRRIGATION POINT OF CONNECTION LOCATIONS. GENERAL NOTES SCOPE OF WORK: PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 6" SDR-35 PVC SANITARY SEWER LATERAL, INCLUDING CLEANOUTS. CONNECT TO EXISTING SEWER MAIN PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2" POLY LATERAL WITH 2" CULINARY WATER METER. 2 1/2" LATERAL EXTENDING FROM METER TO BUILDING PER REXBURG STANDARDS. FIRE HYDRANT ASSEMBLY COMPLETE PER ISPWC STANDARD DRAWING SD-404. 4" CL-52 D.I. FIRE LINE. ENSURE (1) FULL PIPE LENGTH IS INSTALLED BEYOND VALVE. STUB, CAP AND MARK FOR FUTURE WATER LINE CONNECTION. INSTALL TEMPORARY BLOW-OFF/WASHOUT VALVE. SEE MECHANICAL PLANS FOR CONTINUATION. GAS LINE PER INTERMOUNTAIN GAS STANDARDS (SHOWN FOR REFERENCE ONLY). BLIND FLANGE ON VALVE FOR FUTURE CONNECTION. RELOCATED POWER POLE AND OVERHEAD POWER LINE BY LOCAL POWER COMPANY. ROTATE MANHOLE LID TO FURTHEST POSITION FROM CURB AND GUTTER FLOW LINE (EITHER DIRECTION). FIRE DEPARTMENT CONNECTION (SEE PLUMMING DRAWINGS). 7 8 9 1 2 3 4 5 6 10 11 12 CHECKED BYDRAWN BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: SALT LAKE CITY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 WWW.ENSIGNENG.CO E N S I G N THE STANDARD IN ENGINEERING 7835A TH E G R O V E A T T H O M S O N F A R M S 47 2 N O R T H Y E L L O W S T O N E H W Y RE X B U R G , I D A H O REXBURG DEVELOPMENT 160 WEST CANYON ESTATE DRIVE ALPINE, UTAH 84004 PAUL BRINHURST 385-321-1403 J. FORD J. FORDD. COWLEY 8/31/18 2018-05-23 FOR REVIEW CALL DIGLINE @ 811 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.Know what'sbelow. before you dig.Call R FOUND MONUMENT AT THE SOUTHEAST QUARTER OF SECTION 17,T6N, R40E, BOISE B&M ELEVATION = 4875.15 BENCHMARK HORIZONTAL GRAPHIC SCALE 0 ( IN FEET ) HORZ: 1 inch = ft.20 20 10 20 40 C-506 UTILITY PLAN SEE DRAWING C-503SEE DRAWING C-503 SE E D R A W I N G C - 5 0 7 SE E D R A W I N G C - 5 0 7 SE E D R A W I N G C - 5 0 5 SE E D R A W I N G C - 5 0 5 SE E D R A W I N G C - 5 0 8 KEYMAP NOT TO SCALE 1.ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2.EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'S FAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION IN THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THE CONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TO REMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE. 3.ALL SANITARY SEWER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 4.ALL WATER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 6.DEFLECT OR LOOP ALL WATERLINES TO AVOID CONFLICTS WITH OTHER UTILITIES PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 7.PROJECT SHALL COMPLY WITH ALL IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION DRINKING WATER RULES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO, THOSE PERTAINING TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. 8.THE CONTRACTOR IS TO COORDINATE ALL UTILITIES WITH MECHANICAL/PLUMBING PLANS. 9.NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING UTILITY STRUCTURES OR PIPES. 10.THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 11.THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC. UNLESS OTHERWISE NOTED ON THESE PLANS. 12.SEE LANDSCAPE/MECHANICAL PLANS FOR IRRIGATION POINT OF CONNECTION LOCATIONS. GENERAL NOTES SCOPE OF WORK: PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 6" SDR-35 PVC SANITARY SEWER LATERAL, INCLUDING CLEANOUTS. CONNECT TO EXISTING SEWER MAIN PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2" POLY LATERAL WITH 2" CULINARY WATER METER. 2 1/2" LATERAL EXTENDING FROM METER TO BUILDING PER REXBURG STANDARDS. FIRE HYDRANT ASSEMBLY COMPLETE PER ISPWC STANDARD DRAWING SD-404. 4" CL-52 D.I. FIRE LINE. ENSURE (1) FULL PIPE LENGTH IS INSTALLED BEYOND VALVE. STUB, CAP AND MARK FOR FUTURE WATER LINE CONNECTION. INSTALL TEMPORARY BLOW-OFF/WASHOUT VALVE. SEE MECHANICAL PLANS FOR CONTINUATION. GAS LINE PER INTERMOUNTAIN GAS STANDARDS (SHOWN FOR REFERENCE ONLY). BLIND FLANGE ON VALVE FOR FUTURE CONNECTION. RELOCATED POWER POLE AND OVERHEAD POWER LINE BY LOCAL POWER COMPANY. ROTATE MANHOLE LID TO FURTHEST POSITION FROM CURB AND GUTTER FLOW LINE (EITHER DIRECTION). FIRE DEPARTMENT CONNECTION (SEE PLUMMING DRAWINGS). 7 8 9 1 2 3 4 5 6 10 11 12 WV G G G G GGGGGGGGGGGGGGG G G G G W W W W W W W W W W W W W W W WV WV WV WV G G G G G G G G G G G G G G G G W V H Y D HY D WV WV WV G G G G G G G G G G G G G G G H Y D W W W W W W W W W W W W W W W W W W W W W W W W WV W W W W W W W W W W W W W W W W W W W FF=4876.40 SS SS SS SS SS SSSSSSSSSSSS G W G G G G W W W W W W SS SS SS GGG G G G G G G G G G G G FF=4876.00 FF=4876.12 FF=4875.90 FF=4876.65 CLUBHOUSE LINDEN: BUILDING 11 TYPE-A (30 UNITS) HAZELWOOD: BUILDING 4 TYPE-B (20 UNITS) BLACKOAK: BUILDING 5 TYPE-B (20 UNITS) HICKORY: BUILDING 6 TYPE-A (30 UNITS) CO SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S CO CO CO CO WV H Y D SS SS CO G G W WW SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD S D S D SD SD SD SD SD SD FDC FDC F D C D D D S D S D SD S D SD SD SD SD SD SD SD SD SD SD SDSDSD SD S S S S S SSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S S S S S S S S S S S S S S S S S S S S S S S S S INSTALL 4' SSMH #112 RIM=4874.49 FL(OUT-W)=4865.17 INSTALL 5' SSMH #116 RIM=4874.99 FL(IN-E)=4865.11 FL(OUT-W)=4864.31 FL(IN-S)=4865.11 FL(IN-N)=4865.11 INSTALL 4' SSMH #119 RIM=4874.71 FL(OUT-S)=4866.45 FL(IN-E)=4866.50 INSTALL 4' SSMH #115 RIM=4874.23 FL(IN-E)=4863.82 FL(OUT-W)=4863.77 PLUG, CAP, AND MARK FOR FUTURE CONNECTION #118 RIM=4865.92 FL(OUT-N)=4865.19 PLUG, CAP, AND MARK FOR FUTURE CONNECTION #120 RIM=4867.30 FL(OUT-W)=4866.58 PLUG, CAP, AND MARK FOR FUTURE CONNECTION #117 RIM=4866.07 FL(OUT-W)=4865.17 INSTALL 10" SDR-35 PVC-SAN SWR 20.00 L.F. @ 0.28% SLOPE INSTALL 12" SDR-35 PVC-SAN SWR 224.23 L.F. @ 0.22% SLOPE INSTALL 12" SDR- 3 5 P V C - S A N S W R 2 6 4 . 1 6 L . F . @ 0 . 2 2 % S L O P E INSTALL 8" SDR-35 PVC-SAN SWR 270.29 L.F. @ 0.40% SLOPE INSTALL 8" SDR-35 PVC-SAN SWR 20.00 L.F. @ 0.40% SLOPE INSTALL 8" SDR-35 PVC-SAN SWR 20.00 L.F. @ 0.40% SLOPE IN S T A L L 8 " S D R - 3 5 P V C - S A N S W R 3 3 3 . 9 8 L . F . @ 0 . 4 0 % S L O P E 1 7 1 7 1 7 7 7 1 1 INSTALL 8" CL-52 D.I. WATER LINE INSTALL 90° BEND INSTALL 10" CROSS WITH (2) 10" GATE VALVES INSTALL 8" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE INSTALL 8" CL-52 D.I. WATER LINE INSTALL 10" CL-52 D.I. WATER LINE INSTALL 10" CL-52 D.I. WATER LINE 4 6 3 5 35 4 7 7 3 7 75 3 8 8 8 6 6 INSTALL 8" TEE WITH (3) 8" GATE VALVES INSTALL 8" GATE VALVE 4 INSTALL 10" GATE VALVE INSTALL 10" GATE VALVE 6 ST O N E B R I D G E S T R E E T PH A S E 2 FU T U R E THOMSON FARMS ROAD PHASE 2 FUTURE PH A S E 1 PH A S E 2 4 8 8 FUTURE WATER LINE FUTURE WATER LINE 5 SD SD SD SD SD SD SD SD SD SD S D SD SD SD SD SD 12 12 12 CHECKED BYDRAWN BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: SALT LAKE CITY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 WWW.ENSIGNENG.CO E N S I G N THE STANDARD IN ENGINEERING 7835A TH E G R O V E A T T H O M S O N F A R M S 47 2 N O R T H Y E L L O W S T O N E H W Y RE X B U R G , I D A H O REXBURG DEVELOPMENT 160 WEST CANYON ESTATE DRIVE ALPINE, UTAH 84004 PAUL BRINHURST 385-321-1403 J. FORD J. FORDD. COWLEY 8/31/18 2018-05-23 FOR REVIEW CALL DIGLINE @ 811 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.Know what'sbelow. before you dig.Call R FOUND MONUMENT AT THE SOUTHEAST QUARTER OF SECTION 17,T6N, R40E, BOISE B&M ELEVATION = 4875.15 BENCHMARK HORIZONTAL GRAPHIC SCALE 0 ( IN FEET ) HORZ: 1 inch = ft.20 20 10 20 40 C-507 UTILITY PLAN SE E D R A W I N G C - 5 0 5 SE E D R A W I N G C - 5 0 5 SEE DRAWING C-504SEE DRAWING C-504 KEYMAP NOT TO SCALE WV x x x x x x x x x x x x x x x x x x x x ohp ohp ohp ohp ohp ohp ohp ohp x x x w w w w w w w w w w w w w w w EXIST BLG EXIST BLG WV W V H Y D W W W H Y D OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP D SD SD SD SD SD SD S ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss EXIST. SSMH #101EX RIM=4873.37 FL(IN-NE)=4860.04 FL(OUT-SW)=4860.04 EXIST. 12" SAN SWR 397.95 L.F. @ 0.24% SLOPE EXIST. 12" SAN SWR 403.74 L.F. @ 0.23% SLOPE 4 EXIST 12" WATER LINE EXIST 12" WATER LINE OLD U . S . H I G H W A Y 1 9 1 PH A S E 1 FU T U R E 10 10 10 10 10 1.ALL WORK TO COMPLY WITH THE GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2.EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS BASED UPON RECORD INFORMATION AVAILABLE AT THE TIME OF PREPARATION OF THESE PLANS. LOCATIONS MAY NOT HAVE BEEN VERIFIED IN THE FIELD AND NO GUARANTEE IS MADE AS TO THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE EXISTENCE AND LOCATION OF THE UTILITIES SHOWN ON THESE PLANS OR INDICATED IN THE FIELD BY LOCATING SERVICES. ANY ADDITIONAL COSTS INCURRED AS A RESULT OF THE CONTRACTOR'S FAILURE TO VERIFY THE LOCATIONS OF EXISTING UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION IN THEIR VICINITY SHALL BE BORNE BY THE CONTRACTOR AND ASSUMED INCLUDED IN THE CONTRACT. THE CONTRACTOR IS TO VERIFY ALL CONNECTION POINTS WITH THE EXISTING UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE EXISTING UTILITIES AND UTILITY STRUCTURES THAT ARE TO REMAIN. IF CONFLICTS WITH EXISTING UTILITIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO CONSTRUCTION TO DETERMINE IF ANY FIELD ADJUSTMENTS SHOULD BE MADE. 3.ALL SANITARY SEWER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 4.ALL WATER INFRASTRUCTURE TO BE INSTALLED PER REXBURG OR ISPWC STANDARD PLANS AND SPECIFICATIONS. 6.DEFLECT OR LOOP ALL WATERLINES TO AVOID CONFLICTS WITH OTHER UTILITIES PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 7.PROJECT SHALL COMPLY WITH ALL IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION DRINKING WATER RULES AND REGULATIONS INCLUDING, BUT NOT LIMITED TO, THOSE PERTAINING TO BACKFLOW PROTECTION AND CROSS CONNECTION PREVENTION. 8.THE CONTRACTOR IS TO COORDINATE ALL UTILITIES WITH MECHANICAL/PLUMBING PLANS. 9.NOTIFY ENGINEER OF ANY DISCREPANCIES IN DESIGN OR STAKING BEFORE PLACING UTILITY STRUCTURES OR PIPES. 10.THE CONTRACTOR SHALL ADJUST TO GRADE ALL EXISTING UTILITIES AS NEEDED PER LOCAL GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 11.THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS, UTILITIES, AND SIGNS, ETC. UNLESS OTHERWISE NOTED ON THESE PLANS. 12.SEE LANDSCAPE/MECHANICAL PLANS FOR IRRIGATION POINT OF CONNECTION LOCATIONS. GENERAL NOTES SCOPE OF WORK: PROVIDE, INSTALL AND/OR CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED, THE DETAILS NOTED, AND/OR AS SHOWN ON THE CONSTRUCTION DRAWINGS: 6" SDR-35 PVC SANITARY SEWER LATERAL, INCLUDING CLEANOUTS. CONNECT TO EXISTING SEWER MAIN PER GOVERNING AGENCY'S STANDARDS AND SPECIFICATIONS. 2" POLY LATERAL WITH 2" CULINARY WATER METER. 2 1/2" LATERAL EXTENDING FROM METER TO BUILDING PER REXBURG STANDARDS. FIRE HYDRANT ASSEMBLY COMPLETE PER ISPWC STANDARD DRAWING SD-404. 4" CL-52 D.I. FIRE LINE. ENSURE (1) FULL PIPE LENGTH IS INSTALLED BEYOND VALVE. STUB, CAP AND MARK FOR FUTURE WATER LINE CONNECTION. INSTALL TEMPORARY BLOW-OFF/WASHOUT VALVE. SEE MECHANICAL PLANS FOR CONTINUATION. GAS LINE PER INTERMOUNTAIN GAS STANDARDS (SHOWN FOR REFERENCE ONLY). BLIND FLANGE ON VALVE FOR FUTURE CONNECTION. RELOCATED POWER POLE AND OVERHEAD POWER LINE BY LOCAL POWER COMPANY. ROTATE MANHOLE LID TO FURTHEST POSITION FROM CURB AND GUTTER FLOW LINE (EITHER DIRECTION). FIRE DEPARTMENT CONNECTION (SEE PLUMMING DRAWINGS). 7 8 9 1 2 3 4 5 6 10 11 12 CHECKED BYDRAWN BY PROJECT NUMBER FOR: PROJECT MANAGER PRINT DATE PHONE: CONTACT: SALT LAKE CITY 45 W. 10000 S., Suite 500 Sandy, UT 84070 Phone: 801.255.0529 LAYTON Phone: 801.547.1100 TOOELE Phone: 435.843.3590 CEDAR CITY Phone: 435.865.1453 RICHFIELD Phone: 435.896.2983 WWW.ENSIGNENG.CO E N S I G N THE STANDARD IN ENGINEERING 7835A TH E G R O V E A T T H O M S O N F A R M S 47 2 N O R T H Y E L L O W S T O N E H W Y RE X B U R G , I D A H O REXBURG DEVELOPMENT 160 WEST CANYON ESTATE DRIVE ALPINE, UTAH 84004 PAUL BRINHURST 385-321-1403 J. FORD J. FORDD. COWLEY 8/31/18 2018-05-23 FOR REVIEW CALL DIGLINE @ 811 AT LEAST 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.Know what'sbelow. before you dig.Call R FOUND MONUMENT AT THE SOUTHEAST QUARTER OF SECTION 17,T6N, R40E, BOISE B&M ELEVATION = 4875.15 BENCHMARK HORIZONTAL GRAPHIC SCALE 0 ( IN FEET ) HORZ: 1 inch = ft.20 20 10 20 40 C-508 UTILITY PLAN SEE DRAWING C-505SEE DRAWING C-505 SE E D R A W I N G C - 5 0 6 KEYMAP NOT TO SCALE