Loading...
HomeMy WebLinkAboutCOMCHECK - 18-00469 - Thomson Farms the Grove - Clubhouse6�( COMcheck Software Version 4.1.0.0 Mechanical Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: 472 N. Yellowstone Hwy Rexburg, ID 83440 Additional Efficiency Package(s) Unspecified Mechanical Systems List Quantity System Type & Description 2015 I ECC Thomson Farms Clubhouse Rexburg, Idaho 6b New Construction Owner/Agent: Stillwater Equity Partners Designer/Contractor: Dwayne Sudweeks Engineered Systems Assoc., Inc. 1355 E. Center St. Pocatello, ID 83201 208-233-0501 dcs@engsystems.com HVAC System 1 (Single Zone): Heating: 1 each - Duct Furnace, Gas, Capacity = 110 kBtu/h Proposed Efficiency = 95.00% Ec, Required Efficiency: 80.00 % Ec Cooling: 1 each - Split System, Capacity = 54 kBtu/h, Air -Cooled Condenser, No Economizer, Economizer exception: Low Capacity Residential Proposed Efficiency = 13.00 SEER, Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 800 CFM, 0.3 motor nameplate hp, 0.8 fan efficiency grade Water Heater 1: Gas Storage Water Heater, Capacity: 75 gallons, Input Rating: 70 kBtu/h w/ Circulation Pump No minimum efficiency requirement applies Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1,0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. bwau�ne. Sw�w�c�S P�'• r� � u> r Name - TRI 5i ture Dat Project Title: Thomson Farms Clubhouse Data filename: C:\Users\Dwayne 15\Documents\COMcheck\Thomson Farms Clubhouse.cck Report date: 08/20/18 Page 1 of 9 COMcheck Software Version 4.1.0.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section #Plan Review Complies? Comments/Assumptions & Req. IDI C103.2 Plans, specifications, and/or .❑Complies [PR2)1 calculations provide all information❑Does Not with which compliance can be❑Not Observable determined for the mechanical Applicable systems and equipment and❑Not document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans, specifications, and/or ❑Complies [PR3)1 calculations provide all information - ❑Does Not with which compliance can be [-]Not Observable; determined for the service water ❑Not Applicable'. heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. C406 Plans, specifications, and/or ❑Complies [PR911 ;calculations provide all information j❑Does Not with which compliance can be Not Observable :efflclency determined for the additlonal energy ❑Not Applicable package options. Additional Comments/Assumptions: 1 I High Impact (Tier 1)2ij Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Thomson Farms Clubhouse Report date: 08/20/18 Data filename: CAUsers\Dwayne 15\Documents\COMcheck\Thomson Farms Clubhouse.cck Page 2 of 9 # & Re .ID Footing / Foundation Inspection I Complies? .Comments/Assumptions - - C403.2.4. Snow/ice melting system sensors for❑Complies 5, future connection to controls. Freeze j❑Does Not C403.2.4.. protection systems have automatic❑Not Observable 6 [FO9]3,❑Not controls installed. Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Thomson Farms Clubhouse Report date: 08/20/18 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\Thomson Farms Clubhouse.cck Page 3 of 9 Section #Plumbing Rough -In Inspection Complies? Comments/Assumptions & Req.ID C404.5, Heated water supply piping conforms❑Complies C404.5. 1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. '�.❑Not Observable [PL6]3 ❑Not Applicable C404.5, Heated water supply piping conforms❑Complies C404.5.1, to pipe length and volume ❑Does Not C4045.2 requirements. Refer to section details. ❑Not Observable [PL6] ❑Not Applicable C404.6.1, Automatic time switches Installed to ❑Complies C404.6.2 automatically switch off the ❑Does Not [PL311 recirculating hot-water system or heat ❑Not Observable trace. ❑Not Applicable C404.6.3 Pumps that circulate water between a❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to❑Not Observable; <= 5 minutes after end of heating Applicable C404.63 _cycle.;❑Not Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to❑Not Observable <= 5 minutes after end of heating ;❑Not Applicable', cycle. C404.7 Water distribution system that pumps❑Complies Roes [PL8]3 water from a heated -water supply Not pipe back to the heated -water source❑Not Observable through a cold -water supply pipe is a Applicable demand recirculation water system.❑Not Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. C404.7 Water distribution system that pumps❑Complies [PL813 water from a heated -water supply❑Does Not pipe back to the heated -water source❑Not Observable through a cold -water supply pipe is a :❑Not Applicable demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a j user of a fixture or appliance and limits the temperature of the water entering the cold -water piping to 104°F. Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 J Low Impact (Tier 3) Project Title: Thomson Farms Clubhouse Report date: 08/20/18 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\Thomson Farms Clubhouse.cck Page 4 of 9 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Re .ID C402.2.6 Thermally ineffective panel surfaces of;❑Complies [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3.5. ;❑Not Observable; I❑Not Applicable C403.2.13 Unenclosed spaces that are heated I❑Complies [ME71]2 use only radiant heat. j❑Does Not ;❑Not Observable ❑Not Applicable C403.2.3 HVAC equipment efficiency verified.❑Complies See the Mechanical Systems list for values. [ME55]2 -',❑Does Not ❑Not Observable , ❑Not Applicable C403.2.6. Demand control ventilation provided❑Complies 1 for spaces >500 ft2 and >25❑Does Not [ME59]1 people/1000 ft2 occupant density and❑Not Observable; served by systems with air side Applicable economizer, auto modulating outside :❑Not . air damper control, or design airflow >3,000 cfm. C403.2.6. Enclosed parking garage ventilation❑Complies 2 has automatic contaminant detection ❑Does Not (ME115]3 and capacity to stage or modulate ❑Not Observable fans to 50% or less of design capacity. !❑Not Applicable I C403.2.7 Exhaust air energy recovery on ;❑Complies [ME57)1 ! systems meeting Table C403.2.7(1) ❑Does Not and 0403.2.7(2). - ❑Not Observable; I❑Not Applicable C403.2.8 Kitchen exhaust systems comply with Complies [ME116]3 replacement air and conditioned j❑Does Not', supply air limitations, and satisfy hood Observable; rating requirements and maximum❑Not Applicable exhaust rate criteria.❑Not C403.2.9 -. HVAC ducts and plenums Insulated.❑Complies [ME60]' Where ducts or plenums are Installed ❑Does Not in or under a slab, verification may Observable; need to occur during Foundation❑Not Applicable Inspection.❑Not C403.2.9 Ducts and plenums sealed based on I❑complies [ME10]2 static pressure and location. ❑Does Not', ❑Not Observable ❑Not Applicable C403.2.9.. Ductwork operating >3 in. water❑Complies - 1.3 column requires air leakage testing. ❑Does Not [MEll]3 ❑Not Observable ❑Not Applicable C403.4.4. Multiple zone VAV systems with DDC❑Complies ISee the Mechanical Systems list for values. 6 of individual zone boxes have static❑Does Not [ME110]3 pressure setpoint reset controls. :[_-]Not Observable ; ❑Not Applicable I 1 I High Impact (Tier 1) Iffll Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Thomson Farms Clubhouse Report date: 08/20/18 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\Thomson Farms Clubhouse.cck Page 5 of 9 # & Req.ID I Mechanical Rough -In Inspection Complies? C404.2.1 Gas-fired water -heating equipment❑Complies _ [ME111]2 installed in new buildings: where a❑Does Not singular piece of water -heating I Observable; ' equipment >= 1,000 kBtu/h serves❑Not Applicable the entire building, thermal efficiency❑Not >= 90 Et. Where multiple pieces of water -heating equipment serve the building with combined rating >_ 1,000 kBtu/h, the combined input - capacity -weighted -average thermal efficiency >= 90 Et. Exclude input rating of equipment in individual dwelling units and equipment <= 100 kBtu/h. C408.2.2. Air outlets and zone terminal devices❑Complies 1 have means for air balancing.,❑Does Not [ME53]3 ;❑Not Observable; ❑Not ApDlicable C403.5, Refrigerated display cases, walk-in 'LJComplies C403.5.1, coolers or walk-in freezers served by ❑Does Not C403.5.2 remote compressors and remote [ME123)3 condensers not located in a ❑Not Observable condensing unit, have fan -powered ❑Not Applicable condensers that comply with Sections 0403.5.1 and refrigeration compressor' systems that comply with C403.5.2.. Additional Comments/Assumptions: Comments/Assumptions 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 !i I Low Impact (Tier 3) Project Title: Thomson Farms Clubhouse Report date: 08/20/18 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\Thomson Farms Clubhouse.cck Page 6 of 9 Section - -#Final Inspection Complies7 Comments/Assumptions & Reg. ID - C303.3, Furnished O&M manuals for HVAC :❑Complies C408.2.5.: systems within 90 days of system❑Does Not', 3 [F1813 acceptance. ![-]Not Observable; ❑Not Applicable C403.2.2 HVAC systems and equipment❑Complies [F127]3 capacity does not exceed calculated❑Does Not loads. I❑Not Observable I !❑Not Applicable C403.2.4. Heating and cooling to each zone is❑Complies 1 controlled by a thermostat control. :❑Does Not [FI4713 Minimum one humidity control device ;❑Not Observable per installed Applicable humidification/dehumidification❑Not system. C403.2.4. Thermostatic controls have a 5 °F❑Complies 1.2 deadband. j❑Does Not [F[38]3 I❑Not Observable' ❑Not Applicable C403.2.4. Temperature controls have setpoint ;❑Complies , 1.3 overlap restrictions. j❑Does Not [FI20]3 I❑Not Observable; :El Not Applicable C403.2.4. Each zone equipped with setback I❑Complies 2 controls using automatic time clock or :F -]Does Not (F139]3 programmable control system. j❑Not Observable j❑NotAppllcable C403.2.4. Automatic Controls: Setback to 55°F❑Complies 2.1, i (heat) and 85°F (cool); 7 -day clock, 2 -❑Does Not C403.2.4. hour occupant override, 10 -hour EINot Observable; 2.2 :backup [F140]3❑Not Applicable C403.2.4. I Systems include optimum start :]Com 2.3 l controls. �',❑Does Not [F14 1]3 ![]Not Observable I ❑Not Applicable C404.3 Heat traps installed on supply and❑Complies [Fill]3 discharge piping of non -circulating j❑Does Not systems.❑Not bservableI Observable: ❑Not Applicable ONot C404.4 All piping Insulated in accordance with❑Complies [FI25]2 section details and Table C403.2.10. ❑Does Not ,J i❑Not Observable - f❑Not Applicable C404.6.1 Controls are installed that limit the❑Complies [FI12]3 operation of a recirculation pump ❑Does Not installed to maintain temperature of a ❑Not Observable; storage tank. System return pipe is a ❑Not Applicable dedicated return pipe or a cold water supply pipe. C408.2.1 Commissioning plan developed by❑Complies [F12811 registered design professional or j❑Does Not j approved agency. j❑Not Observable ❑Not Applicable 1 JHIgh Impact (Tier 1) JIM Medium Impact (Tier 2) '''39 Low Impact (Tier 3) Project Title: Thomson Farms Clubhouse Report date: 08/20/18 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\Thomson Farms Clubhouse.cck Page 7 of 9 Section --_-----_--- # Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.3. HVAC equipment has been tested to❑Complies 1 ensure proper operation. ❑Does Not [FI31]1❑Not Observable; ❑Not Applicable C408.2.3. HVAC control systems have been ❑Complies 2 -tested to ensure proper operation, ❑Does Not [FI10]1 calibration and adjustment of controls..❑Not Observable []Not Applicable C408.2.4 Preliminary commissioning report '❑Complles [F129]1 completed and certified by registered :❑Does Not design professional or approved Observable; agency.❑Not j❑Not Applicable C408.2.5. Furnished HVAC as -built drawings ;❑Complies 1 'submitted within 90 days of system j❑Does Not [F]7]3 acceptance. ❑Not Observable I❑Not Applicable C408.2.5. An air and/or hydronlc system❑Complies 3 balancing report is provided for HVAC .❑Does Not [FI43]1 systems. ;❑Not Observable; ❑Not Applicable j C408.2.5. Final commissioning report due to❑Complies 4 building owner within 90 days of j❑Does Not [F130]1 receipt of certificate of occupancy. I❑Not Observable I ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Thomson Farms Clubhouse Report date: 08/20/18 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\Thomson Farms Clubhouse.cck Page 8 of 9 Project Title: Thomson Farms Clubhouse Report date: 08/20/18 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\Thomson Farms Clubhouse.cck Page 9 of 9