Loading...
HomeMy WebLinkAboutCOMCHECK - 18-00315 - Approx. 1000 N Yellowstone Hwy - The Grove at Thomson Farms - 30 Unit Bldg6 COMcheck Software Version 4.0.8.1 �( Envelope Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Thomson Property Rexburg Apartments Location: Rexburg, Idaho Climate Zone: 6b Project Type: New Construction Vertical Glazing /Wall Area: 10% Construction Site: Owner/Agent: Designer/Contractor: North Yellowstone Hwy Paul Bringhurst Cory Ferguson Rexburg, ID 83440 Stillwater Equity Partners GOULD+ Architects, LLC 160 W Canyon Crest Rd 427 West 11950 South, Suite 201 Alpine, UT 84004 Draper, UT 84020 801.216.8850 801,335.9900 paul@stillwatermail.com cory@gouldplus.com Additional Efficiency Package(s) Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Building Area Floor Area 1 -first floor (Multifamily) : Nonresidential 8595 2 -second floor (Multifamily) : Nonresidential 8595 3 -third floor (Multifamily) : Nonresidential 8595 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U - or R -Value R -Value U -Factor Facton.) Perimeter Floor 1: Slab-On-Grade:Unheated, Vertical 2 ft., [Bldg. Use 1 - first 882 --- 15.0 0.520 0.540 floor] (c) Floor 2: Wood -Framed, [Bldg. Use 2 - second floor] 882 30.0 0.0 0.033 0.033 Floor 3: Wood -Framed, [Bldg. Use 3 - third floor] 882 30.0 0.0 0.033 0.033 Roof 1: Attic Roof with Wood Joists, [Bldg. Use 3 - third floor] 8595 49.0 0.0 0.021 0.021 NORTH Exterior Wall 1: Wood -Framed, 16" o.c., [Bldg. Use 1 - first floor] 1583 21.0 0.0 0.062 0.051 Window 1: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID 150 --- --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 1 - first floor] (b) Window 13: Wood Frame:Fixed, Perf. Specs.: Product ID JELDWEN 80 --- --- 0.270 0.360 Steel Sidelite in Wood Frame LowE w/ Grids, SHGC 0. 15, [Bldg. Use 1 - first floor] (b) Door 7: Insulated Metal, Swinging, [Bldg. Use 1 - first floor] 62 --- --- 0.160 0.370 Door 22: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. 80 --- --- 0.290 0.770 Specs.: Product ID JELDWEN Steel Door Full Lite LowE w/ Grids, SHGC 0.25, [Bldg. Use 1 - first floor] (b) Exterior Wall 5: Wood -Framed, 24" o .c., [Bldg. Use 2 - second floor] 1583 21.0 0.0 0.060 0.051 Window 2: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID 150 --- --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 2 - second floor] (b) Door 8: Insulated Metal, Swinging, [Bldg. Use 2 - second floor] 62 --- --- 0.160 0.370 Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\!18000\18006 -Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELE Page 1 of 10 WEN.cck Assembly Gross Area Cavity Cont. Proposed Budget U - or R -Value R -Value U -Factor Factor(.) Perimeter Door 24: Glass (> 50% glazing): Nonmetal Frame, Entrance Door, Pert. 158 --- --- 0.320 0.770 Specs.: Product ID JELDWEN Patio Vinyl Low E, SHGC 0.30, [Bldg. Use 2 - second floor] (b) Exterior Wall 9: Wood -Framed, 24" o .c., [Bldg. Use 3 - third floor] 1583 21.0 0.0 0.060 0.051 Window 3: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID 150 --- --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 3 - third floor] (b) Door 9: Insulated Metal, Swinging, [Bldg. Use 3 - third floor] 62 --- --- 0.160 0.370 Door 26: Glass (> 50% glazing): Nonmetal Frame, Entrance Door, Pert. 158 --- --- 0.320 0.770 Specs.: Product ID JELDWEN Patio Vinyl Low E, SHGC 0.30, [Bldg. Use 3 - third floor] (b) EAST Exterior Wall 2: Wood -Framed, 16" o.c., [Bldg. Use 1 - first floor] 2515 21.0 0.0 0.062 0.051 Window 7: Vinyl/Fiberglass Frame:Operable, Pert. Specs.: Product ID 50 -- - 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 1 - first floor] (b) Window 14: Wood Frame:Fixed, Perf. Specs.: Product ID JELDWEN 20 -- --- 0.270 0.360 Steel Sidelite in Wood Frame LowE w/ Grids, SHGC 0.15, [Bldg. Use 1 - first floor] (b) Door 2: Insulated Metal, Swinging, [Bldg. Use 1 - first floor] 100 --- --- 0.160 0.370 Door 19: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. 20 --- --- 0.290 0.770 Specs.: Product ID JELDWEN Steel Door Full Lite LowE w/ Grids, SHGC 0.25, [Bldg. Use 1 - first floor] (b) Exterior Wall 6: Wood -Framed, 24" o .c., [Bldg. Use 2 - second floor] 2515 21.0 0.0 0.060 0.051 Window 8: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID 100 --- --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 2 - second floor] (b) Door 3: Insulated Metal, Swinging, [Bldg. Use 2 - second floor] 100 --- --- 0.160 0.370 Door 20: Glass (> 50% glazing): Nonmetal Frame, Entrance Door, Perf. 40 -- --- 0.320 0.770 Specs.: Product ID JELDWEN Patio Vinyl Low E, SHGC 0.30, [Bldg. Use 2 - second floor] (b) Exterior Wall 10: Wood -Framed, 24" o.c., [Bldg. Use 3 - third floor] 2515 21.0 0.0 0.060 0.051 Window 9: Vinyl/Fiberglass Frame:Operable, Pert. Specs.: Product ID 100 -- --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 3 - third floor] (b) Door 5: Insulated Metal, Swinging, [Bldg. Use 3 - third floor] 100 --- --- 0.160 0.370 Door 21: Glass (> 50% glazing): Nonmetal Frame, Entrance Door, Perf. 40 -- -- 0.320 0.770 Specs.: Product ID JELDWEN Patio Vinyl Low E, SHGC 0.30, [Bldg. Use 3 - third floor] (b) SOUTH Exterior Wall 3: Wood -Framed, 16" o.c., [Bldg. Use 1 - first floor] 1588 21.0 0.0 0.062 0.051 Window 4: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID 150 --- --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 1 - first floor] (b) Window 15: Wood Frame:Fixed, Pert. Specs.: Product ID JELDWEN 80 -- - 0.270 0.360 Steel Sidelite in Wood Frame LowE w/ Grids, SHGC 0. 15, [Bldg. Use 1 - first floor] (b) Door 10: Insulated Metal, Swinging, [Bldg. Use 1 - first floor] 62 -- --- 0.160 0.370 Door 23: Glass (> 50% glazing):Metal Frame, Entrance Door, Pert. 80 -- --- 0.290 0.770 Specs.: Product ID JELDWEN Steel Door Full Lite LowE w/ Grids, SHGC 0.25, [Bldg. Use 1 - first floor] (b) Exterior Wall 7: Wood -Framed, 24" o .c., [Bldg. Use 2 - second floor] 1588 21.0 0.0 0.060 0.051 Window 5: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID 150 - - --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 2 - second floor] (b) Door 11: Insulated Metal, Swinging, [Bldg. Use 2 - second floor] 62 -- -- 0.160 0.370 Door 25: Glass (> 50% glazing): Nonmetal Frame, Entrance Door, Perf. 158 -- --- 0.320 0.770 Specs.: Product ID JELDWEN Patio Vinyl Low E, SHGC 0.30, [Bldg. Use 2 - second floor] (b) Exterior Wall 11: Wood -Framed, 24" o .c., [Bldg. Use 3 - third floor] 1588 21.0 0.0 0.060 0.051 Window 6: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID 150 -- - 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 3 - third floor] (b) Door 12: Insulated Metal, Swinging, [Bldg. Use 3 - third floor] 62 -- --- 0.160 0.370 Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\!18000\18006 -Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELE Page 2 of 10 WEN.cck Assembly Gross Area Cavity Cont. Proposed Budget U - or R -Value R -Value U -Factor Factor(.) Perimeter Door 27: Glass (> 50% glazing): Nonmetal Frame, Entrance Door, Perf. 158 -- - 0.320 0.770 Specs.: Product ID JELDWEN Patio Vinyl Low E, SHGC 0.30, [Bldg. Use 3 - third floor] (b) WEST Exterior Wall 4: Wood -Framed, 16" o.c., [Bldg. Use 1 - first floor] 2515 21.0 0.0 0.062 0.051 Window 10: Vinyl/Fiberglass Frame:Operable, Pert. Specs.: Product ID 25 --- --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 1 - first floor] (b) Window 16: Wood Frame:Fixed, Perf. Specs.: Product ID JELDWEN 20 -- --- 0.270 0.360 Steel Sidelite in Wood Frame LowE w/ Grids, SHGC 0.15, [Bldg. Use 1 - first floor] (b) Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - first floor] 100 --- - 0.160 0.370 Door 13: Insulated Metal, Swinging, [Bldg. Use 1 - first floor] 16 --- - 0.280 0.370 Door 16: Glass (> 50% glazing):Metal Frame, Entrance Door, Pert. 20 -- - 0.290 0.770 Specs.: Product ID JELDWEN Steel Door Full Lite LowE w/ Grids, SHGC 0.25, [Bldg. Use 1 - first floor] (b) Exterior Wall 8: Wood -Framed, 24" o .c., [Bldg. Use 2 - second floor] 2786 21.0 0.0 0.060 0.051 Window 11: Vinyl/Fiberglass Frame:Operable, Pert. Specs.: Product ID 75 -- --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 2 - second floor] (b) Door 4: Insulated Metal, Swinging, [Bldg. Use 2 - second floor] 100 --- --- 0.160 0.370 Door 14: Insulated Metal, Swinging, [Bldg. Use 2 - second floor] 16 --- --- 0.160 0.370 Door 17: Glass (> 50% glazing): Nonmetal Frame, Entrance Door, Pert. 40 - --- 0.320 0.770 Specs.: Product ID JELDWEN Patio Vinyl Low E, SHGC 0.30, [Bldg. Use 2 - second floor] (b) Exterior Wall 12: Wood -Framed, 24" o .c., [Bldg. Use 3 - third floor] 2515 21.0 0.0 0.060 0.051 Window 12: Vinyl/Fiberglass Frame:Operable, Pert. Specs.: Product ID 75 --- --- 0.320 0.430 NA, SHGC 0.30, [Bldg. Use 3 - third floor] (b) Door 6: Insulated Metal, Swinging, [Bldg. Use 3 - third floor] 100 -- - 0.160 0.370 Door 15: Insulated Metal, Swinging, [Bldg. Use 3 - third floor] 16 -- --- 0.160 0.370 Door 18: Glass (> 50% glazing): Nonmetal Frame, Entrance Door, Pert. 40 -- --- 0.320 0.770 Specs.: Product ID JELDWEN Patio Vinyl Low E, SHGC 0.30, [Bldg. Use 3 - third floor] (b) (a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab -On -Grade proposed and budget U -factors shown in table are F -factors. EnvelopeDesign better than code Envelope Compliance Statement Compliance Statement. The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Cory Ferguson - Architect � / 2018.06.27 Name - Title Signature Date Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\! 18000\18006 -Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELL Page 3 of 10 WEN.cck eCOMcheck Software Version 4.0.8.1 �(J Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID _ C103.2 Plans and/or specifications provide all ❑Complies Requirement will be met. _ [PR1]1 information with which compliance ❑Does Not can be determined for the building ❑Not Observable envelope and document where ❑Not exceptions to the standard are Applicable claimed. C402.4.1 The vertical fenestration area <= 30 ❑Complies Requirement will be met. [PR10]1 percent of the gross above -grade wall ❑Does Not area. ❑Not Observable ❑Not Applicable C402.4.1 The skylight area <= 3 percent of the ❑Complies Requirement will be met. A [PR1111 gross roof area. ❑Does Not [_-]Not Observable Location on plans/spec: Not Applicable ❑Not Applicable C406 Plans, specifications, and/or ❑Complies Requirement will be met. [PR9]1 calculations provide all information ❑Does Not with which compliance can be determined for the additional energy ❑Not Observable L� efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) I Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\118000\18006 -Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELL Page 4 of 10 WEN.cck Complies? I Comments/Assumptions C303.2 Slab edge insulation installed per ❑Complies Requirement will be met. [F04]2 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C303.2.1 Exterior insulation protected against ❑Complies Requirement will be met. [F06]1 damage, sunlight, moisture, wind, []Does Not landscaping and equipment ❑Not Observable maintenance activities. ❑Not Applicable C402.2.5 Slab edge insulation R -value. ❑Complies See the Envelope Assemblies table for values. [F03]2 ❑Does Not ❑Not Observable ❑Not Applicable C402.2.6 Radiant heating systems panels ❑Complies Exception: Requirement does not apply. [FO12]3 insulated to >=R-3.5 on face opposite ❑Does Not space being heated. ❑Not Observable See the Envelope Assemblies table for values. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1L—J..,2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\!18000\18006 -Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELL Page 5 of 10 WEN.cck Section # Framing / Rough -In Inspection Complies? Comments/Assumptions & Re .ID C303.1.3 Fenestration products rated in ❑Complies Requirement will be met. [FR12]2 accordance with NFRC. ❑Does Not ❑Not Observable _ ❑Not Applicable C303.1.3 Fenestration products are certified as ❑Complies Requirement will be met. [FR13]1 to performance labels or certificates ❑Does Not provided. ❑Not Observable ❑Not Applicable C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values. [FR10]1 ❑Does Not ❑Not Observable ❑Not Applicable C402.4.3, Vertical fenestration U -Factor. ❑Complies See the Envelope Assemblies table for values. C402.4.3. ❑Does Not 4 [FR8]1 ❑Not Observable ❑Not Applicable C402.4.4 U -factor of opaque doors associated ❑Complies See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ❑Does Not meets requirements. ❑Not Observable _ ❑Not Applicable C402.5.1. The building envelope contains a ❑Complies _ Requirement will be met. 2.1 continuous air barrier that is sealed in ❑Does Not [FR19]1 an approved manner and material []Not Observable permeability <= 0.004 dfm/ft2. Air barrier penetrations are sealed in an ❑Not Applicable approved manner. C402.5.2_ Factory -built fenestration and doors ❑Complies Requirement will be met. C402.5.4 are labeled as meeting air leakage ❑Does Not [FR18]3 requirements. ❑Not Observable _ ❑Not Applicable C402.5.7 Vestibules are installed on all building ❑Complies Exception: Doors that open directly from a space =3000 ft2. [FR17]3 entrances. Doors have self-closing ❑Does Not devices. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2_1 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\!18000\18006 -Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELL Page 6 of 10 WEN.cck Section # Mechanical Rough -In Inspection Complies? Comments/Assumptions & Rea.ID C402.5.5, Stair and elevator shaft vents have LJComplies Exception: Requirement does not apply. C403.2.4. motorized dampers that automatically ❑Does Not 3 close. [ME3]3 ❑Not Observable ❑Not Applicable C402.5.5, Outdoor air and exhaust systems have ❑Complies Requirement will be met. C403.2.4, motorized dampers that automatically ❑Does Not 3 shut when not in use and meet [ME58]3 maximum leakage rates. Check ❑Not Observable gravity dampers where allowed. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3) _ Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\!18000\18006 -Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELL Page 7 of 10 WEN.cck Section #Insulation Inspection Complies? Comments/Assumptions & Reci.ID _ C303.1 Roof insulation installed per ❑Complies Requirement will be met. [IN311 manufacturer's instructions. Blown or ❑Does Not poured loose -fill insulation is installed ❑Not Observable only where the roof slope is <=3 in ❑Not Applicable 12. C303.1 Building envelope insulation is labeled ❑Complies Requirement will be met. [IN10]2 with R -value or insulation certificate ❑Does Not providing R -value and other relevant ❑Not Observable data. ❑Not Applicable C303.2 Above -grade wall insulation installed ❑Complies Requirement will be met. [IN711 per manufacturer's instructions. ❑Does Not []Not Observable ❑Not Applicable C303.2, Floor insulation installed per ❑Complies Exception: All perimeter framing fully insulated at metal or C402.2.4 manufacturer's instructions. Cavity or ❑Does Not wood framed prescriptive levels. [IN9]2 structural slab insulation installed in ❑Not Observable permanent contact with underside of ❑Not Applicable decking or structural slabs. C303.2.1 Exterior insulation is protected from ❑Complies Exception: Requirement does not apply. [IN14]2 damage with a protective material. ❑Does Not Verification for exposed foundation ❑Not Observable insulation may need to occur during ❑Not Applicable _ Foundation Inspection. C402.2.1 Insulation intended to meet the roof ❑Complies Requirement will be met. [IN1713 insulation requirements cannot be ❑Does Not installed on top of a suspended ceiling. Mark this requirement ❑Not Observable compliant if insulation is installed ❑Not Applicable accordingly. _ C402.2.3 Above -grade wall insulation R -value. ❑Complies See the Envelope Assemblies table for values. _ [IN6]1 ❑Does Not ❑Not Observable ❑Not Applicable C402.2.5 Floor insulation R -value. ❑Complies See the Envelope Assemblies table for values. [IN8]2 ❑Does Not ❑Not Observable _ ❑Not Applicable C402.2.6 Radiant panels and associated ❑Complies Exception: Requirement does not apply. [IN18]3 components, designed for heat ❑Does Not transfer from the panel surfaces to the ❑Not Observable occupants or indoor space are insulated with a minimum of R-3.5. ❑Not Applicable C402.2.2 Roof R -value. For some ceiling ❑Complies See the Envelope Assemblies table for values. [IN211 systems, verification may need to ❑Does Not occur during Framing Inspection. [-]Not Observable _ ❑Not Applicable C402.5.1, All sources of air leakage in the ❑Complies Requirement will be met. 1 building thermal envelope are sealed, ❑Does Not [IN111 caulked, gasketed, weather stripped []Not Observable or wrapped with moisture vapor- ❑Not permeable wrapping material to Applicable minimize air leakage. Additional Comments/Assumptions: 1 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 Low Impact (Tier 3) Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\!18000\18006 -Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELL Page 8 of 10 WEN.cck Section # Final Inspection Complies? Comments/Assumptions & RegJD C402.5.3 Where open combustion air ducts ❑Complies Requirement will be met. [F151]3 provide combustion air to open ❑Does Not combustion fuel burning appliances, ❑Not Observable the appliances and combustion air ❑Not Applicable opening are located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms are sealed and insulated. C402.5.6 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [F137]1 dock cargo doors. ❑Does Not ❑Not Observable ❑Not Applicable C402.5.8 Recessed luminaires in thermal ❑Complies Requirement will be met. [F126]3 envelope to limit infiltration and be IC ❑Does Not rated and labeled. Seal between ❑Not Observable interior finish and luminaire housing. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\!18000\18006 - Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELL Page 9 of 10 WEN.cck Project Title: Thomson Property Rexburg Apartments Report date: 07/02/18 Data filename: X:\!18000\18006 -Rexburg Apartments\18006-1\COMcheck\Rexburb Apartments -3 STORY JELL Page 10 of 10 WEN.cck