Loading...
HomeMy WebLinkAboutPLANS - 18-00362 - 19 College Ave - AC Moore - Sign19 College Ave Rexburg, ID 83440 R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. Co l l e g e A ve E Main Street SIGN A SIGN B SIGN C SIGN D SIGN E SIGN F 48" AC Moore 163.33 Internally Illuminated LED Type: Illumination: Square Footage: SIGN A Channel Letters on a Raceway Internally Illuminated LED 31 1/2" AC Moore, 14 1/4” Arts.. 79.32 Type: Illumination: Square Footage: SIGN E Individual Front-Lit channel ltrs/ Remote 24" Create More 34.45 Internally Illuminated LED Type: Illumination: Square Footage: SIGN B Channel Letters on a Raceway 24" Share More 31.60 Internally Illuminated LED Type: Illumination: Square Footage: SIGN C Channel Letters on a Raceway 24" Save More 28.92 Internally Illuminated LED Type: Illumination: Square Footage: SIGN D Channel Letters on a Raceway Non-Illuminated Multiple; AC Moore Panel signs 12.00 Type: Illumination: Square Footage: SIGN F Aluminum panel wall sign R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. Allowable Square Footage this Elevation: Formula: 16' x 166' = 2656 x 10% = 265.60 Actual Square Footage this Elevation: 265.60 DRAWINGS ARE FOR LEASE PURPOSES ONLY. ALL MEASUREMENTS TO BE FIELD VERIFIED PRIOR TO FABRICATION. 163.33 Front Elevation (West) / Left End Scale: 1/8” = 1’-0" Existing 53 " 166'-0" Lease Dimension 48 ” EQ EQ EQ EQ 48" AC Moore 163.33 Internally Illuminated LED Type: Illumination: Square Footage: SIGN A Channel Letters on a Raceway CL 21 3 / 4 ” 21 3 / 4 ” 40'-10" R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. Allowable Square Footage this Elevation: Formula: 16' x 166' = 2656 x 10% = 265.60 Actual Square Footage this Elevation: 265.60 DRAWINGS ARE FOR LEASE PURPOSES ONLY. ALL MEASUREMENTS TO BE FIELD VERIFIED PRIOR TO FABRICATION. 94.97 Front Elevation (West) / Right End Scale: 1/8” = 1’-0" Existing 166'-0" Lease Dimension 24" Create More 34.45 Internally Illuminated LED Type: Illumination: Square Footage: SIGN B Channel Letters on a Raceway 24" Share More 31.60 Internally Illuminated LED Type: Illumination: Square Footage: SIGN C Channel Letters on a Raceway 24" Save More 28.92 Internally Illuminated LED Type: Illumination: Square Footage: SIGN D Channel Letters on a Raceway 17'-2 3/4"EQ EQ EQ EQ EQ EQ 24 ” 24 ” 15'-9 1/2" 24 ” 14'-5 1/2" R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. Allowable Square Footage this Elevation: Formula: 16' x 82' = 1312 x 10% = 131.20 Actual Square Footage this Elevation: 131.20 DRAWINGS ARE FOR LEASE PURPOSES ONLY. ALL MEASUREMENTS TO BE FIELD VERIFIED PRIOR TO FABRICATION. 79.32 Rear Elevation (East) Scale: 1/16” = 1’-0" Existing 83 " EQ EQ EQEQ 166'-0" Lease Dimension 28'-0" Internally Illuminated LED 31 1/2" AC Moore, 14 1/4” Arts.. 79.32 Type: Illumination: Square Footage: SIGN E Individual Front-Lit channel ltrs/ Remote 4’ - 1 1 / 2 ” 19’-2 3/4” Non-Illuminated Multiple; AC Moore Panel signs 12.00 Type: Illumination: Square Footage: SIGN F Aluminum panel wall sign Framing FashionCrafts EverydayCrafts CandyMaking SeasonalHoliday DecorFabrics Scapbooking Crafts Home Decor Yarn I3I1 I5 I7 I9 I11 I4I2 I6 I8 I10 I12 R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. 5”4 1/2” Scale: N.T.S. S ec tio n @ LED C ha n nel Le tter R aceway 1 2 4 5 6 3 12 ¼” Drain holes at bottom of letter cans w/ light baffles. For exterior signage only 8 13 9 11 7 10 Specifications: Channel Letters Red LEDs (X) 60w Power Supplies Total Amps: X.XX (1) 20 amp 120V Circuit Req. Electrical Detail: PMS #186 Red, #2793 Red Acrylic Color Specifications: 1. Existing Facade: To be determined 2. 0.040” Aluminum letter returns pre-finished “Hunter Red” 3. 1”Jewelite trimcap (Red) bonded to face and #8 pan head screws to returns 4. 0.063” pre-finished white aluminum backs fastened to returns. Seal w/ VOC compliant 360 white latex caulk to prevent moisture penetration. 5. Red LED’s 6. 3/16” #2793 Red Acrylic faces 7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6 8. Primary electrical feed in UL conduit / customer supplied UL junction box 9. Power Supplies 10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted to match the facade (color TBD) 11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP) 12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters. 13. Mounting hardware to suit 48" AC Moore 163.33 Internally Illuminated LED Type: Illumination: Square Footage: SIGN A Channel Letters on a Raceway Scale: 3/16" = 1'-0" Sign Layout Detail 48 ” [490”] [351 1/2”][126 1/4”] 21 3 / 4 ” 21 3 / 4 ” 40'-10" 29'-3 1/2"10'-6 1/4" General Notes: This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. - Grounded and bonded per NEC 600.7/NEC 250 - Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps - Sign is to be UL listed per NEC 600.3 - UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer. For multiple signs, a disconnect is permitted but not required for each section - The location of the disconnect switch after installa- tion shall comply with artilcle 600.6 (A) (1) per NEC 5”4 1/2” Scale: N.T.S. S ec tio n @ LED C ha n nel Le tter R aceway 1 2 4 5 6 3 12 ¼” Drain holes at bottom of letter cans w/ light baffles. For exterior signage only 8 13 9 11 7 10 Specifications: Channel Letters Red LEDs (X) 60w Power Supplies Total Amps: X.XX (1) 20 amp 120V Circuit Req. Electrical Detail: PMS #186 Red, #2793 Red Acrylic Color Specifications: 1. Existing Facade: To be determined 2. 0.040” Aluminum letter returns pre-finished “Hunter Red” 3. 1”Jewelite trimcap (Red) bonded to face and #8 pan head screws to returns 4. 0.063” pre-finished white aluminum backs fastened to returns. Seal w/ VOC compliant 360 white latex caulk to prevent moisture penetration. 5. Red LED’s 6. 3/16” #2793 Red Acrylic faces 7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6 8. Primary electrical feed in UL conduit / customer supplied UL junction box 9. Power Supplies 10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted to match the facade (color TBD) 11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP) 12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters. 13. Mounting hardware to suit General Notes: This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. - Grounded and bonded per NEC 600.7/NEC 250 - Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps - Sign is to be UL listed per NEC 600.3 - UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer. For multiple signs, a disconnect is permitted but not required for each section - The location of the disconnect switch after installa- tion shall comply with artilcle 600.6 (A) (1) per NEC 24" Create More 34.45 Internally Illuminated LED Type: Illumination: Square Footage: SIGN B Channel Letters on a Raceway Scale: 3/8" = 1'-0" Sign Layout Detail R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. 17'-2 3/4"[206 3/4”] 24 ” 5”4 1/2” Scale: N.T.S. S ec tio n @ LED C ha n nel Le tter R aceway 1 2 4 5 6 3 12 ¼” Drain holes at bottom of letter cans w/ light baffles. For exterior signage only 8 13 9 11 7 10 Specifications: Channel Letters Red LEDs (X) 60w Power Supplies Total Amps: X.XX (1) 20 amp 120V Circuit Req. Electrical Detail: PMS #186 Red, #2793 Red Acrylic Color Specifications: 1. Existing Facade: To be determined 2. 0.040” Aluminum letter returns pre-finished “Hunter Red” 3. 1”Jewelite trimcap (Red) bonded to face and #8 pan head screws to returns 4. 0.063” pre-finished white aluminum backs fastened to returns. Seal w/ VOC compliant 360 white latex caulk to prevent moisture penetration. 5. Red LED’s 6. 3/16” #2793 Red Acrylic faces 7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6 8. Primary electrical feed in UL conduit / customer supplied UL junction box 9. Power Supplies 10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted to match the facade (color TBD) 11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP) 12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters. 13. Mounting hardware to suit General Notes: This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. - Grounded and bonded per NEC 600.7/NEC 250 - Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps - Sign is to be UL listed per NEC 600.3 - UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer. For multiple signs, a disconnect is permitted but not required for each section - The location of the disconnect switch after installa- tion shall comply with artilcle 600.6 (A) (1) per NEC R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. 24" Share More 31.60 Internally Illuminated LED Type: Illumination: Square Footage: SIGN C Channel Letters on a Raceway Scale: 3/8" = 1'-0" Sign Layout Detail 24 ” 15'-9 1/2"[189 1/2”] 5”4 1/2” Scale: N.T.S. S ec tio n @ LED C ha n nel Le tter R aceway 1 2 4 5 6 3 12 ¼” Drain holes at bottom of letter cans w/ light baffles. For exterior signage only 8 13 9 11 7 10 Specifications: Channel Letters Red LEDs (X) 60w Power Supplies Total Amps: X.XX (1) 20 amp 120V Circuit Req. Electrical Detail: PMS #186 Red, #2793 Red Acrylic Color Specifications: 1. Existing Facade: To be determined 2. 0.040” Aluminum letter returns pre-finished “Hunter Red” 3. 1”Jewelite trimcap (Red) bonded to face and #8 pan head screws to returns 4. 0.063” pre-finished white aluminum backs fastened to returns. Seal w/ VOC compliant 360 white latex caulk to prevent moisture penetration. 5. Red LED’s 6. 3/16” #2793 Red Acrylic faces 7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6 8. Primary electrical feed in UL conduit / customer supplied UL junction box 9. Power Supplies 10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted to match the facade (color TBD) 11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP) 12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters. 13. Mounting hardware to suit General Notes: This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. - Grounded and bonded per NEC 600.7/NEC 250 - Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps - Sign is to be UL listed per NEC 600.3 - UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer. For multiple signs, a disconnect is permitted but not required for each section - The location of the disconnect switch after installa- tion shall comply with artilcle 600.6 (A) (1) per NEC R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. 24" Save More 28.92 Internally Illuminated LED Type: Illumination: Square Footage: SIGN D Channel Letters on a Raceway Scale: 3/8" = 1'-0" Sign Layout Detail 24 ” 14'-5 1/2"[173 1/2”] R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. Scale: 3/8" = 1'-0" Sign Layout Detail Specifications: Channel Letters Red LEDs (X) 60w Power Supplies Total Amps: X.XX (1) 20 amp 120V Circuit Req. Electrical Detail: Internally Illuminated LED 31 1/2" AC Moore, 14 1/4” Arts.. 79.32 Type: Illumination: Square Footage: SIGN E Individual Front-Lit channel ltrs/ Remote PMS #186 Red, #2793 Red Acrylic Color Specifications: ¼” Drain holes at bottom of letter cans w/ light baffles. For exterior signage only Scale: N.T.S. Sec t i o n @ L E D Cha nne l Le t te r 1 2 3 9 10 7 8 4 5 6 5” 31 1 / 2 ” 14 1 / 4 ” [4 9 1 / 2 ” ] [166 3/4”] [230 3/4”] 4’ - 1 1 / 2 ” 19’-2 3/4” 13’-10 3/4” 1. Existing Facade: To be determined 2. 0.040” Aluminum letter returns pre-finished “Hunter Red” 3. 1”Jewelite trimcap (Red) bonded to face, #8 pan head screws to returns. Note: 2” trimcaps for letters 54” and larger .125” ACM backs (pre-finished white) fastened to returns. Seal w/ VOC compliant 4. 360 white latex caulk to prevent moisture penetration. 5. Red LEDs 6. 3/16” #2793 Red Acrylic faces 7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6 8. Primary electrical feed in UL conduit / customer supplied UL junction box 9. Power Supplies within UL enclosure (removable lid), 1/4” x 1” min screws 10. Mounting Hardware to suit General Notes: This sign is to be installed in accordance with the requirements of Article 600 of the National Electrical Code. - Grounded and bonded per NEC 600.7/NEC 250 - Existing branch circuit in compliance with NEC 600.5, not to exceed 20 amps - Sign is to be UL listed per NEC 600.3 - UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer. For multiple signs, a disconnect is permitted but not required for each section - The location of the disconnect switch after installa- tion shall comply with artilcle 600.6 (A) (1) per NEC Tapcon Section @ Panel Sign Scale: 1 1/2" = 1'-0" Scale: 3/8" = 1'-0" Sign Layout Detail 1. New 0.080” painted white aluminum panels 2. Applied vinyl per color specifications Specifications: Color Specifications: PMS #186 Red, #3730-33L Red vinyl R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440 19 College Ave Rexburg, ID 83440 115588 Patrick Mendelsohn Mike DeMarco 05/17/2018 Project ID#: Project Mgr: Designer: Created on: R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I. Art Supplies Needlecraft Framing FashionCrafts EverydayCraftsCandyMaking SeasonalHoliday DecorFabricsScapbooking Crafts Home Decor Yarn 72”72”72” 24 ” 24 ” 24 ” 24 ” I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 Non-Illuminated Multiple; AC Moore Panel signs 12.00 Type: Illumination: Square Footage: SIGN F Aluminum panel wall sign