HomeMy WebLinkAboutPLANS - 18-00362 - 19 College Ave - AC Moore - Sign19 College Ave Rexburg, ID 83440
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
Co
l
l
e
g
e
A ve
E Main Street
SIGN A
SIGN B
SIGN C
SIGN D
SIGN E
SIGN F
48" AC Moore
163.33
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN A
Channel Letters on a Raceway
Internally Illuminated LED
31 1/2" AC Moore, 14 1/4” Arts..
79.32
Type:
Illumination:
Square Footage:
SIGN E
Individual Front-Lit channel ltrs/ Remote
24" Create More
34.45
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN B
Channel Letters on a Raceway
24" Share More
31.60
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN C
Channel Letters on a Raceway
24" Save More
28.92
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN D
Channel Letters on a Raceway
Non-Illuminated
Multiple; AC Moore Panel signs
12.00
Type:
Illumination:
Square Footage:
SIGN F
Aluminum panel wall sign
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
Allowable Square Footage this Elevation:
Formula: 16' x 166' = 2656 x 10% = 265.60
Actual Square Footage this Elevation:
265.60
DRAWINGS ARE FOR LEASE PURPOSES ONLY.
ALL MEASUREMENTS TO BE FIELD VERIFIED
PRIOR TO FABRICATION.
163.33
Front Elevation (West) / Left End
Scale: 1/8” = 1’-0"
Existing
53
"
166'-0" Lease Dimension
48
”
EQ
EQ
EQ EQ
48" AC Moore
163.33
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN A
Channel Letters on a Raceway
CL
21
3
/
4
”
21
3
/
4
”
40'-10"
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
Allowable Square Footage this Elevation:
Formula: 16' x 166' = 2656 x 10% = 265.60
Actual Square Footage this Elevation:
265.60
DRAWINGS ARE FOR LEASE PURPOSES ONLY.
ALL MEASUREMENTS TO BE FIELD VERIFIED
PRIOR TO FABRICATION. 94.97
Front Elevation (West) / Right End
Scale: 1/8” = 1’-0"
Existing
166'-0" Lease Dimension
24" Create More
34.45
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN B
Channel Letters on a Raceway
24" Share More
31.60
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN C
Channel Letters on a Raceway
24" Save More
28.92
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN D
Channel Letters on a Raceway
17'-2 3/4"EQ EQ EQ EQ EQ EQ
24
”
24
”
15'-9 1/2"
24
”
14'-5 1/2"
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
Allowable Square Footage this Elevation:
Formula: 16' x 82' = 1312 x 10% = 131.20
Actual Square Footage this Elevation:
131.20
DRAWINGS ARE FOR LEASE PURPOSES ONLY.
ALL MEASUREMENTS TO BE FIELD VERIFIED
PRIOR TO FABRICATION. 79.32
Rear Elevation (East)
Scale: 1/16” = 1’-0"
Existing
83
"
EQ
EQ
EQEQ
166'-0" Lease Dimension
28'-0"
Internally Illuminated LED
31 1/2" AC Moore, 14 1/4” Arts..
79.32
Type:
Illumination:
Square Footage:
SIGN E
Individual Front-Lit channel ltrs/ Remote
4’
-
1
1
/
2
”
19’-2 3/4”
Non-Illuminated
Multiple; AC Moore Panel signs
12.00
Type:
Illumination:
Square Footage:
SIGN F
Aluminum panel wall sign
Framing
FashionCrafts EverydayCrafts
CandyMaking
SeasonalHoliday DecorFabrics
Scapbooking
Crafts
Home Decor Yarn
I3I1 I5 I7 I9 I11
I4I2 I6 I8 I10 I12
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
5”4 1/2”
Scale: N.T.S.
S ec tio n @ LED C ha n nel Le tter
R aceway
1
2
4
5
6
3
12
¼” Drain holes at bottom
of letter cans w/ light baffles.
For exterior signage only
8
13
9 11
7
10
Specifications: Channel Letters
Red LEDs
(X) 60w Power Supplies
Total Amps: X.XX
(1) 20 amp 120V Circuit Req.
Electrical Detail:
PMS #186 Red, #2793 Red Acrylic
Color Specifications:
1. Existing Facade: To be determined
2. 0.040” Aluminum letter returns pre-finished “Hunter Red”
3. 1”Jewelite trimcap (Red) bonded to face and #8 pan head screws to returns
4. 0.063” pre-finished white aluminum backs fastened to returns. Seal w/
VOC compliant 360 white latex caulk to prevent moisture penetration.
5. Red LED’s
6. 3/16” #2793 Red Acrylic faces
7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6
8. Primary electrical feed in UL conduit / customer supplied UL junction box
9. Power Supplies
10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted
to match the facade (color TBD)
11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP)
12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters.
13. Mounting hardware to suit
48" AC Moore
163.33
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN A
Channel Letters on a Raceway
Scale: 3/16" = 1'-0"
Sign Layout Detail
48
”
[490”]
[351 1/2”][126 1/4”]
21
3
/
4
”
21
3
/
4
”
40'-10"
29'-3 1/2"10'-6 1/4"
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
- Grounded and bonded per NEC 600.7/NEC 250
- Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
- Sign is to be UL listed per NEC 600.3
- UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer. For
multiple signs, a disconnect is permitted but not
required for each section
- The location of the disconnect switch after installa-
tion shall comply with artilcle 600.6 (A) (1) per NEC
5”4 1/2”
Scale: N.T.S.
S ec tio n @ LED C ha n nel Le tter
R aceway
1
2
4
5
6
3
12
¼” Drain holes at bottom
of letter cans w/ light baffles.
For exterior signage only
8
13
9 11
7
10
Specifications: Channel Letters
Red LEDs
(X) 60w Power Supplies
Total Amps: X.XX
(1) 20 amp 120V Circuit Req.
Electrical Detail:
PMS #186 Red, #2793 Red Acrylic
Color Specifications:
1. Existing Facade: To be determined
2. 0.040” Aluminum letter returns pre-finished “Hunter Red”
3. 1”Jewelite trimcap (Red) bonded to face and #8 pan head screws to returns
4. 0.063” pre-finished white aluminum backs fastened to returns. Seal w/
VOC compliant 360 white latex caulk to prevent moisture penetration.
5. Red LED’s
6. 3/16” #2793 Red Acrylic faces
7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6
8. Primary electrical feed in UL conduit / customer supplied UL junction box
9. Power Supplies
10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted
to match the facade (color TBD)
11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP)
12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters.
13. Mounting hardware to suit
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
- Grounded and bonded per NEC 600.7/NEC 250
- Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
- Sign is to be UL listed per NEC 600.3
- UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer. For
multiple signs, a disconnect is permitted but not
required for each section
- The location of the disconnect switch after installa-
tion shall comply with artilcle 600.6 (A) (1) per NEC
24" Create More
34.45
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN B
Channel Letters on a Raceway
Scale: 3/8" = 1'-0"
Sign Layout Detail
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
17'-2 3/4"[206 3/4”]
24
”
5”4 1/2”
Scale: N.T.S.
S ec tio n @ LED C ha n nel Le tter
R aceway
1
2
4
5
6
3
12
¼” Drain holes at bottom
of letter cans w/ light baffles.
For exterior signage only
8
13
9 11
7
10
Specifications: Channel Letters
Red LEDs
(X) 60w Power Supplies
Total Amps: X.XX
(1) 20 amp 120V Circuit Req.
Electrical Detail:
PMS #186 Red, #2793 Red Acrylic
Color Specifications:
1. Existing Facade: To be determined
2. 0.040” Aluminum letter returns pre-finished “Hunter Red”
3. 1”Jewelite trimcap (Red) bonded to face and #8 pan head screws to returns
4. 0.063” pre-finished white aluminum backs fastened to returns. Seal w/
VOC compliant 360 white latex caulk to prevent moisture penetration.
5. Red LED’s
6. 3/16” #2793 Red Acrylic faces
7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6
8. Primary electrical feed in UL conduit / customer supplied UL junction box
9. Power Supplies
10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted
to match the facade (color TBD)
11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP)
12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters.
13. Mounting hardware to suit
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
- Grounded and bonded per NEC 600.7/NEC 250
- Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
- Sign is to be UL listed per NEC 600.3
- UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer. For
multiple signs, a disconnect is permitted but not
required for each section
- The location of the disconnect switch after installa-
tion shall comply with artilcle 600.6 (A) (1) per NEC
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
24" Share More
31.60
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN C
Channel Letters on a Raceway
Scale: 3/8" = 1'-0"
Sign Layout Detail
24
”
15'-9 1/2"[189 1/2”]
5”4 1/2”
Scale: N.T.S.
S ec tio n @ LED C ha n nel Le tter
R aceway
1
2
4
5
6
3
12
¼” Drain holes at bottom
of letter cans w/ light baffles.
For exterior signage only
8
13
9 11
7
10
Specifications: Channel Letters
Red LEDs
(X) 60w Power Supplies
Total Amps: X.XX
(1) 20 amp 120V Circuit Req.
Electrical Detail:
PMS #186 Red, #2793 Red Acrylic
Color Specifications:
1. Existing Facade: To be determined
2. 0.040” Aluminum letter returns pre-finished “Hunter Red”
3. 1”Jewelite trimcap (Red) bonded to face and #8 pan head screws to returns
4. 0.063” pre-finished white aluminum backs fastened to returns. Seal w/
VOC compliant 360 white latex caulk to prevent moisture penetration.
5. Red LED’s
6. 3/16” #2793 Red Acrylic faces
7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6
8. Primary electrical feed in UL conduit / customer supplied UL junction box
9. Power Supplies
10. Low profile extruded aluminum raceway (7” x 4 1/2”) w/ watertight cover. All painted
to match the facade (color TBD)
11. 2” Aluminum mounting clips, Maximum 6” from each end and every 48” o.c. (TYP)
12. Rivets, 3/16” aluminum #66 (letter to raceway fastening) Thru bolt attachment for large letters.
13. Mounting hardware to suit
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
- Grounded and bonded per NEC 600.7/NEC 250
- Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
- Sign is to be UL listed per NEC 600.3
- UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer. For
multiple signs, a disconnect is permitted but not
required for each section
- The location of the disconnect switch after installa-
tion shall comply with artilcle 600.6 (A) (1) per NEC
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
24" Save More
28.92
Internally Illuminated LED
Type:
Illumination:
Square Footage:
SIGN D
Channel Letters on a Raceway
Scale: 3/8" = 1'-0"
Sign Layout Detail
24
”
14'-5 1/2"[173 1/2”]
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
Scale: 3/8" = 1'-0"
Sign Layout Detail
Specifications: Channel Letters
Red LEDs
(X) 60w Power Supplies
Total Amps: X.XX
(1) 20 amp 120V Circuit Req.
Electrical Detail:
Internally Illuminated LED
31 1/2" AC Moore, 14 1/4” Arts..
79.32
Type:
Illumination:
Square Footage:
SIGN E
Individual Front-Lit channel ltrs/ Remote
PMS #186 Red, #2793 Red Acrylic
Color Specifications:
¼” Drain holes at bottom
of letter cans w/ light baffles.
For exterior signage only
Scale: N.T.S.
Sec t i o n @ L E D Cha nne l Le t te r
1
2
3 9
10
7
8
4
5
6
5”
31
1
/
2
”
14
1
/
4
”
[4
9
1
/
2
”
]
[166 3/4”]
[230 3/4”]
4’
-
1
1
/
2
”
19’-2 3/4”
13’-10 3/4”
1. Existing Facade: To be determined
2. 0.040” Aluminum letter returns pre-finished “Hunter Red”
3. 1”Jewelite trimcap (Red) bonded to face, #8 pan head screws to returns.
Note: 2” trimcaps for letters 54” and larger
.125” ACM backs (pre-finished white) fastened to returns. Seal w/ VOC compliant 4.
360 white latex caulk to prevent moisture penetration.
5. Red LEDs
6. 3/16” #2793 Red Acrylic faces
7. Disconnect switch UL Outdoor rated toggle type w/ neoprene boot per NEC 600-6
8. Primary electrical feed in UL conduit / customer supplied UL junction box
9. Power Supplies within UL enclosure (removable lid), 1/4” x 1” min screws
10. Mounting Hardware to suit
General Notes:
This sign is to be installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
- Grounded and bonded per NEC 600.7/NEC 250
- Existing branch circuit in compliance with
NEC 600.5, not to exceed 20 amps
- Sign is to be UL listed per NEC 600.3
- UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer. For
multiple signs, a disconnect is permitted but not
required for each section
- The location of the disconnect switch after installa-
tion shall comply with artilcle 600.6 (A) (1) per NEC
Tapcon
Section @ Panel Sign
Scale: 1 1/2" = 1'-0"
Scale: 3/8" = 1'-0"
Sign Layout Detail
1. New 0.080” painted white aluminum panels
2. Applied vinyl per color specifications
Specifications:
Color Specifications:
PMS #186 Red, #3730-33L Red vinyl
R1 05/21/18 SB Add tagline to Sign A raceway, Sign E note external lighting by others
R2 05/24/18 MD Added signs B, C & D; panel signsA.C. Moore #83440
19 College Ave
Rexburg, ID 83440
115588
Patrick Mendelsohn
Mike DeMarco
05/17/2018
Project ID#:
Project Mgr:
Designer:
Created on:
R3 06/05/18 JD Removed signs F, G, H and option 2 on sign I.
Art Supplies Needlecraft
Framing FashionCrafts
EverydayCraftsCandyMaking
SeasonalHoliday DecorFabricsScapbooking
Crafts
Home Decor
Yarn
72”72”72”
24
”
24
”
24
”
24
”
I1 I2 I3
I4 I5 I6
I7 I8 I9
I10 I11 I12
Non-Illuminated
Multiple; AC Moore Panel signs
12.00
Type:
Illumination:
Square Footage:
SIGN F